Clinical applications of tandem mass spectrometry: ten years of diagnosis and screening for inherited metabolic diseases.

This paper reviews the clinical applications of tandem mass spectrometry (MS-MS) in diagnosis and screening for inherited metabolic diseases in the last 10 years. The broad-spectrum of diseases covered, specificity, ease of sample preparation, and high throughput provided by the MS-MS technology has led to the development of multi-disorder newborn screening programs in many countries for amino acid disorders, organic acidemias, and fatty acid oxidation defects. Issues related to sample acquisition, sample preparation, quantification of metabolites, and validation are discussed. Our current experience with the technique in screening is presented. The application of MS-MS in selective screening has revolutionized the field and made a major impact on the detection of certain disease classes such as the fatty acid oxidation defects. New specific and rapid MS-MS and LC-MS-MS methods for highly polar small molecules are supplementing or replacing some of the classical GC-MS methods for a multitude of metabolites and disorders. New exciting applications are appearing in fields of prenatal, postnatal, and even postmortem diagnosis. Examples for pitfalls in the technique are also presented.

[1]  Yukie Tanaka,et al.  Prenatal Diagnosis of Organic Acidemias Based on Amniotic Fluid Levels of Acylcarnitines , 1996, Pediatric Research.

[2]  B. Shushan,et al.  Development of a Method for Rapid Quantitation of Amino Acids by Liquid Chromatography-Tandem Mass Spectrometry (LC-MSMS) in Plasma , 2000, Clinical chemistry and laboratory medicine.

[3]  J. Evans,et al.  Screening techniques for the detection of inborn errors of bile acid metabolism by direct injection and micro-high performance liquid chromatography-continuous flow/fast atom bombardment mass spectrometry. , 1993, Biological mass spectrometry.

[4]  S. J. Smith,et al.  Validation of accuracy-based amino acid reference materials in dried-blood spots by tandem mass spectrometry for newborn screening assays. , 1999, Clinical chemistry.

[5]  B. Casetta,et al.  Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry. , 1999, Clinical chemistry.

[6]  M. Rashed,et al.  Application of electrospray tandem mass spectrometry to neonatal screening. , 1999, Seminars in perinatology.

[7]  M. Bialer,et al.  PRENATAL DIAGNOSIS OF MITOCHONDRIAL FATTY ACID OXIDATION DEFECTS , 1996, Prenatal diagnosis.

[8]  D. Millington,et al.  The analysis of diagnostic markers of genetic disorders in human blood and urine using tandem mass spectrometry with liquid secondary ion mass spectrometry , 1991 .

[9]  E. Hoffman,et al.  Medium Chain Acyl-CoA Dehydrogenase Deficiency in Pennsylvania: Neonatal Screening Shows High Incidence and Unexpected Mutation Frequencies , 1995, Pediatric Research.

[10]  S. Cederbaum,et al.  Isolated isobutyryl-CoA dehydrogenase deficiency: an unrecognized defect in human valine metabolism. , 1998, Molecular genetics and metabolism.

[11]  K. Gempel,et al.  Rapid determination of total homocysteine in blood spots by liquid chromatography-electrospray ionization-tandem mass spectrometry. , 2000, Clinical chemistry.

[12]  K. Setchell,et al.  Inborn Errors of Bile Acid Synthesis , 1987, Seminars in liver disease.

[13]  D. Millington,et al.  Automated analysis for free and short-chain acylcarnitine in plasma with a centrifugal analyzer. , 1992, Clinical chemistry.

[14]  M. Morris,et al.  Screening for medium chain acyl-CoA dehydrogenase deficiency using electrospray ionisation tandem mass spectrometry , 1998, Archives of disease in childhood.

[15]  M. Jacob,et al.  Screening blood spots for inborn errors of metabolism by electrospray tandem mass spectrometry with a microplate batch process and a computer algorithm for automated flagging of abnormal profiles. , 1997, Clinical chemistry.

[16]  K. Mills,et al.  A Method for the Quantitation of Conjugated Bile Acids in Dried Blood Spots Using Electrospray Ionization-Mass Spectrometry , 1998, Pediatric Research.

[17]  M. E. Harrison,et al.  Electrospray tandem mass spectrometry in the diagnosis of organic acidemias , 1994 .

[18]  D. Millington,et al.  Assay for free and total carnitine in human plasma using tandem mass spectrometry. , 2000, Clinical chemistry.

[19]  J. Leonard,et al.  Diagnosis of medium chain acyl CoA dehydrogenase deficiency by measurement of cis-4-decenoic acid in dried blood spots. , 1992, Clinica chimica acta; international journal of clinical chemistry.

[20]  J. Bocxlaer,et al.  Solid-phase extraction technique for gas-chromatographic profiling of acylcarnitines. , 1993 .

[21]  H. Aboul‐Enein,et al.  Chiral liquid chromatography tandem mass spectrometry in the determination of the configuration of 2-hydroxyglutaric acid in urine. , 2000, Biomedical chromatography : BMC.

[22]  D. Turnbull,et al.  The measurement of carnitine and acyl-carnitines: application to the investigation of patients with suspected inherited disorders of mitochondrial fatty acid oxidation. , 1992, Clinica chimica acta; international journal of clinical chemistry.

[23]  G C Cunningham,et al.  Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours. , 1998, Clinical chemistry.

[24]  I. Björkhem Inborn errors of metabolism with consequences for bile acid biosynthesis. A minireview. , 1994, Scandinavian journal of gastroenterology. Supplement.

[25]  C. Roe,et al.  Investigation of beta-oxidation intermediates in normal and MCAD-deficient human fibroblasts using tandem mass spectrometry. , 1995, Biochemical and molecular medicine.

[26]  D. Gompertz,et al.  The specificity of glycine-N-acylase and acylglycine excretion in the organicacidaemias. , 1974, Biochemical medicine.

[27]  B. Warrack,et al.  Ion spray liquid chromatographic/mass spectrometric characterization of bile acids. , 1993, Biological mass spectrometry.

[28]  M. Bucknall,et al.  Diagnosis of Inborn Errors of Metabolism from Blood Spots by Acylcarnitines and Amino Acids Profiling Using Automated Electrospray Tandem Mass Spectrometry , 1995, Pediatric Research.

[29]  E. de Hoffmann,et al.  Bile acids and conjugates identified in metabolic disorders by fast atom bombardment and tandem mass spectrometry. , 1991, Clinical chemistry.

[30]  Bernhard Liebl,et al.  Modellprojekt zur Neuordnung des Neugeborenen-Screenings in Bayern: Konzeption und erste Ergebnisse , 2000 .

[31]  E. Mayatepek,et al.  Sensitivity of electrospray-tandem mass spectrometry using the phenylalanine/tyrosine-ratio for differential diagnosis of hyperphenylalaninemia in neonates. , 1999, Clinica chimica acta; international journal of clinical chemistry.

[32]  D. Turnbull,et al.  Measurement of the acyl-CoA intermediates of beta-oxidation by h.p.l.c. with on-line radiochemical and photodiode-array detection. Application to the study of [U-14C]hexadecanoate oxidation by intact rat liver mitochondria. , 1989, The Biochemical journal.

[33]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[34]  D. Millington,et al.  Rapid diagnosis of maple syrup urine disease in blood spots from newborns by tandem mass spectrometry. , 1995, Clinical chemistry.

[35]  M. Levene,et al.  Determination of plasma total homocysteine and cysteine using HPLC with fluorescence detection and an ammonium 7-fluoro-2, 1, 3-benzoxadiazole-4-sulphonate (SBD-F) derivatization protocol optimized for antioxidant concentration, derivatization reagent concentration, temperature and matrix pH. , 1996, Biomedical chromatography : BMC.

[36]  J. Vederas,et al.  N-acylglycine amidation: implications for the biosynthesis of fatty acid primary amides. , 1999, Biochemistry.

[37]  D. Chace,et al.  Rapid diagnosis of MCAD deficiency: quantitative analysis of octanoylcarnitine and other acylcarnitines in newborn blood spots by tandem mass spectrometry. , 1997, Clinical chemistry.

[38]  M. Bennett,et al.  Inborn errors of metabolism diagnosed in sudden death cases by acylcarnitine analysis of postmortem bile. , 1995, Clinical chemistry.

[39]  C. Roe,et al.  Evidence for Intermediate Channeling in Mitochondrial -Oxidation (*) , 1995, The Journal of Biological Chemistry.

[40]  C. Hoppel,et al.  Quantification of free carnitine, individual short- and medium-chain acylcarnitines, and total carnitine in plasma by high-performance liquid chromatography. , 1993, Analytical biochemistry.

[41]  D. Turnbull,et al.  Quantitation of acyl-CoA and acylcarnitine esters accumulated during abnormal mitochondrial fatty acid oxidation. , 1991, The Journal of biological chemistry.

[42]  K. Setchell,et al.  Serum bile acid analysis. , 1983, Clinica chimica acta; international journal of clinical chemistry.

[43]  D. Millington,et al.  Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry. , 1993, Clinical chemistry.

[44]  C. Roe,et al.  Recent developments in the investigation of inherited metabolic disorders using cultured human cells. , 1999, Molecular genetics and metabolism.

[45]  M. Fujioka,et al.  Prenatal diagnosis of isovaleric acidemia by fast atom bombardment and tandem mass spectrometry. , 1991, Clinica chimica acta; international journal of clinical chemistry.

[46]  R. McGuinness,et al.  Erythrocyte galactose-I-phosphate uridyl transferase and glucose-6-phosphate dehydrogenase activity in the population of the Rhondda Fach. , 1967, Clinica chimica acta; international journal of clinical chemistry.

[47]  M. Morris,et al.  Screening of newborn infants for cholestatic hepatobiliary disease with tandem mass spectrometry , 1999, BMJ.

[48]  C. Heizmann,et al.  Evaluation of urinary acylglycines by electrospray tandem mass spectrometry in mitochondrial energy metabolism defects and organic acidurias. , 2000, Molecular genetics and metabolism.