Two‐step navigatorless correction algorithm for radial k‐space MRI acquisitions

A new way to correct magnetic resonance image artifacts resulting from view‐dependent phase variations and view‐dependent variations in rigid body object translation is presented by exploiting basic properties of the trajectory of radial k‐space acquisitions. Simulations, phantom studies, and in vivo experiments are used to demonstrate the feasibility and the utility of this method. While somewhat analogous to navigator echo correction, in which special gradients are interleaved into the imaging sequence so echoes at the center of k‐space can be acquired prior to or after collection of the image data, the current method does not require additional new gradient structures within the pulse sequence or increases in scan time. The new method uses the phase information from all collected radial k‐space data points rather than only the navigator echo, which permits correction of multiple sources of view‐dependent phase variation in the image data. The resultant effect is improved image quality in radial MRI acquisitions. Magn Reson Med 45:277–288, 2001. © 2001 Wiley‐Liss, Inc.

[1]  J. Duerk,et al.  Motion artifact suppression technique (MAST) for MR imaging. , 1987, Journal of computer assisted tomography.

[2]  A. Louis,et al.  Picture reconstruction from projections in restricted range , 1980 .

[3]  G. Glover,et al.  Self‐navigated spiral fMRI: Interleaved versus single‐shot , 1998, Magnetic resonance in medicine.

[4]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[5]  J G Pipe,et al.  Effect of bulk tissue motion on quantitative perfusion and diffusion magnetic resonance imaging , 1991, Magnetic resonance in medicine.

[6]  A. Haase,et al.  Rapid NMR Imaging Using Low Flip-Angle Pulses , 2004 .

[7]  G H Glover,et al.  Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan Methods , 1995, Magnetic resonance in medicine.

[8]  R L Ehman,et al.  Adaptive motion compensation in MR imaging without use of navigator echoes. , 1991, Radiology.

[9]  M. L. Wood,et al.  MR image artifacts from periodic motion. , 1985, Medical physics.

[10]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[11]  L. Axel,et al.  Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints. , 1996, Medical physics.

[12]  L Axel,et al.  Respiratory effects in two-dimensional Fourier transform MR imaging. , 1986, Radiology.

[13]  Jerry L. Prince,et al.  Hierarchical reconstruction using geometry and sinogram restoration , 1993, IEEE Trans. Image Process..

[14]  R E Wendt,et al.  Motional phase artifacts in fourier transform MRI , 1989, Magnetic resonance in medicine.

[15]  Paul R. Edholm,et al.  Novel Properties Of The Fourier Decomposition Of The Sinogram , 1986, Other Conferences.

[16]  X. Hu,et al.  Reduction of signal fluctuation in functional MRI using navigator echoes , 1994, Magnetic resonance in medicine.

[17]  A F Gmitro,et al.  Use of a projection reconstruction method to decrease motion sensitivity in diffusion‐weighted MRI , 1993, Magnetic resonance in medicine.

[18]  Jens Frahm,et al.  Transverse coherence in rapid FLASH NMR imaging , 1987 .

[19]  S J Riederer,et al.  Algorithms for extracting motion information from navigator echoes , 1996, Magnetic resonance in medicine.

[20]  S J Riederer,et al.  Compensation for effects of linear motion in MR imaging , 1989, Magnetic resonance in medicine.

[21]  D Rosenfeld,et al.  An optimal and efficient new gridding algorithm using singular value decomposition , 1998, Magnetic resonance in medicine.

[22]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[23]  Gary H. Glover,et al.  Method for reducing image artifacts due to periodic signal variations in NMR imaging , 1987 .

[24]  Richard Lorne Ehman,et al.  Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. , 1987 .

[25]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[26]  R. Turner,et al.  Echo-planar imaging: magnetic resonance imaging in a fraction of a second. , 1991, Science.

[27]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[28]  G H Glover,et al.  Lung parenchyma: magnetic susceptibility in MR imaging. , 1991, Radiology.

[29]  J Hennig,et al.  Spiral reconstruction by regridding to a large rectilinear matrix: A practical solution for routine systems , 1999, Journal of magnetic resonance imaging : JMRI.

[30]  D C Noll,et al.  Consistent projection reconstruction (CPR) techniques for MRI , 1993, Magnetic resonance in medicine.

[31]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[32]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[33]  R L Ehman,et al.  Spatial presaturation: a method for suppressing flow artifacts and improving depiction of vascular anatomy in MR imaging. , 1987, Radiology.