Visual field loss in senile dementia of the Alzheimer's type

Article abstract-Background: Visual performance is impaired in patients with senile dementia of the Alzheimer's type (SDAT). We investigated the visual field topography of these deficits. Methods: Humphrey automated perimetry (Program 30-2) was used to measure differential luminance sensitivity within the central 60 degrees of the visual field in SDAT patients (n = 61) and in visually and cognitively normal volunteer subjects of similar age (n = 61). Twenty-three SDAT patients were retested 18 months after the original examination. Results: Reliable visual fields (by manufacturer's criteria) were obtained in 72.1% (44/61) of the control subjects and 55.7% (34/61) of the SDAT group. In the SDAT group, differential luminance sensitivity was significantly reduced relative to the control group. Visual sensitivity was reduced throughout the visual field, but deficits were most pronounced in the inferior visual field, where they presented most commonly as arcuate defects. Patients with more severe dementia exhibited greater reductions in visual sensitivity. On follow-up, 14 of 23 SDAT patients exhibited progression of visual field loss, whereas only two of 23 patients exhibited a regression of the visual field loss. Conclusions: Although automated perimetry requires considerable patient cooperation, many patients with SDAT can produce reliable visual field results. These patients exhibit significant reductions in global sensitivity. Visual field loss in SDAT is most pronounced in the inferonasal and inferotemporal arcuate regions of the visual field but also involves the central field. NEUROLOGY 1995;45: 68-74

[1]  G. Gilmore,et al.  Motion perception and Alzheimer's disease. , 1994, Journal of gerontology.

[2]  J. Morrison,et al.  Quantitative analysis of a vulnerable subset of pyramidal neurons in Alzheimer's disease: II. Primary and secondary visual cortex , 1990, The Journal of comparative neurology.

[3]  C. Miller,et al.  Optic-nerve degeneration in Alzheimer's disease. , 1986, The New England journal of medicine.

[4]  G. Trick,et al.  Visual sensitivity to motion , 1991, Neurology.

[5]  J. Kurtzke,et al.  On the production of neurologists in the United States , 1991, Neurology.

[6]  F. Buonanno,et al.  Spatial vision in Alzheimer's disease. General findings and a case report. , 1985, Archives of neurology.

[7]  Douglas R. Anderson Automated Static Perimetry , 1992 .

[8]  R. Beck,et al.  Baseline visual field profile of optic neuritis. The experience of the optic neuritis treatment trial. Optic Neuritis Study Group. , 1993, Archives of ophthalmology.

[9]  V. Iragui,et al.  Abnormal pattern electroretinogram in Alzheimer's disease: Evidence for retinal ganglion cell degeneration? , 1989, Annals of neurology.

[10]  M. Barris,et al.  Abnormal pattern electroretinograms in patients with senile dementia of the alzheimer type , 1989, Annals of neurology.

[11]  J Katz,et al.  Reliability indexes of automated perimetric tests. , 1988, Archives of ophthalmology.

[12]  Suzanne Corkin,et al.  Visual dysfunction in Alzheimer's disease: Relation to normal aging , 1991, Annals of neurology.