Ongoing evolution of advanced SAG mill control at Ok Tedi
暂无分享,去创建一个
At Ok Tedi, ore type and SAG feed size distribution vary widely and frequently. This makes control of the SAG mills by application of the power/pressure relationship difficult. Power logic has traditionally been conservative due to power spikes associated with rapid size-distribution changes. A new expert system was installed in early 2000. The system incorporates multiple state fuzzy logic to deal with frequent and radical ore type and size variations, along with monitoring of motor temperatures. A short-term power spike no longer warrants immediate radical action. This has resulted in increased mill throughput and improved circuit stability.