Commissioning and Performance of the CMS Pixel Tracker with Cosmic Ray Muons

The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. ∗See Appendix A for the list of collaboration members ar X iv :0 91 1. 54 34 v2 [ ph ys ic s. in sde t] 2 F eb 2 01 0

[1]  R. Horisberger,et al.  Development of an Indium Bump Bond Process for Silicon Pixel Detectors at PSI , 2005, physics/0510021.

[2]  P. Merkel Experience with mass production bump bonding with outside vendors in the CMS FPIX project , 2007 .

[3]  T. Hebbeker,et al.  Simulation of Cosmic Muons and Comparison with Data from the Cosmic Challenge using Drift Tube Chambers , 2007 .

[4]  P. V. Vavilov IONIZATION LOSSES OF HIGH-ENERGY HEAVY PARTICLES , 1957 .

[5]  D. Kotlinski,et al.  Status of the CMS Pixel detector , 2009 .

[6]  João Paulo Teixeira,et al.  The CMS experiment at the CERN LHC , 2008 .

[7]  K. Prokofiev,et al.  Simulation of heavily irradiated silicon pixel sensors and comparison with test beam measurements , 2004, IEEE Transactions on Nuclear Science.

[8]  Tilman Rohe,et al.  Silicon sensors development for the CMS pixel system , 2003 .

[9]  E. Alagöz Simulation and beam test measurements of the CMS pixel detector , 2009 .

[10]  Veikko Karimäki,et al.  The CMS tracker system project : Technical Design Report , 1997 .

[11]  G. Bruno,et al.  Stand-alone cosmic muon reconstruction before installation of the CMS silicon strip tracker , 2009, 0902.1860.

[12]  R. Horisberger,et al.  Design and performance of the silicon sensors for the CMS barrel pixel detector , 2008 .

[13]  D. Bortoletto The CMS pixel system , 2007 .

[14]  Alan D. Lopez,et al.  Radiation tolerance of the CMS forward pixel detector , 2009 .

[15]  G. Bolla,et al.  Irradiation studies of silicon pixel detectors for CMS , 2003 .

[16]  A. Schmidt,et al.  Mechanical design and material budget of the CMS barrel pixel detector , 2009, 0904.4761.

[17]  R. Horisberger,et al.  Building CMS pixel barrel detector modules , 2007, physics/0702181.

[18]  W. Erdmann,et al.  Design and performance of the CMS pixel detector readout chip , 2006 .

[19]  R. Horisberger,et al.  The control and readout systems of the CMS pixel barrel detector , 2006 .