Design and Performance Characterization Strategy Using Modeling for Biofiltration Control of Odorous Hydrogen Sulfide

Abstract Biofilter, dynamic modeling software characterizing contaminant removal via biofiltration, was used in the preliminary design of a biofilter to treat odorous hydrogen sulfide (H2S). Steady-state model simulations were run to generate performance plots for various influent concentrations, loadings, residence times, media sizes, and temperatures. Although elimination capacity and removal efficiency frequently are used to characterize biofilter performance, effluent concentration can be used to characterize performance when treating to a target effluent concentration. Model simulations illustrate that, at a given temperature, a biofilter cannot reduce H2S emissions below a minimum value, no matter how large the biofilter or how long the residence time. However, a higher biofilter temperature results in lower effluent H2S concentrations. Because dynamic model simulations show that shock loading can significantly increase the effluent concentration above values predicted by the steady-state model simulations, it is recommended that, to consistently meet treatment objectives, dynamic feed conditions should be considered. This study illustrates that modeling can serve as a valuable tool in the design and performance optimization of biofilters.

[1]  Performance of a directionally-switching biofilter treating toluene contaminated air , 1996 .

[2]  George Tchobanoglous,et al.  Small and decentralized wastewater management systems , 1998 .

[3]  James R. Mihelcic,et al.  Field Measurements and Modeling of Two-Stage Biofilter that Treats Odorous Sulfur Air Emissions , 2003 .

[4]  H. Cox,et al.  Odor and Volatile Organic Compound Removal from Wastewater Treatment Plant Headworks Ventilation Air Using a Biofilter , 2003, Water environment research : a research publication of the Water Environment Federation.

[5]  J. Mihelcic,et al.  Optimization of Biofiltration for Odor Control: Model Calibration, Validation, and Applications , 2002, Water environment research : a research publication of the Water Environment Federation.

[6]  J. Devinny,et al.  Treatment of Mixed Hydrogen Sulfide and Organic Vapors in a Rock Medium Biofilter , 2001 .

[7]  P. Martikainen,et al.  Oxidation of Gas Mixtures Containing Dimethyl Sulfide, Hydrogen Sulfide, and Methanethiol Using a Two-Stage Biotrickling Filter , 2001, Journal of the Air & Waste Management Association.

[8]  E. Meiburg,et al.  A computational model for heterogeneous flow through low headloss biofilter media , 2002 .

[9]  E. R. Allen,et al.  Biofiltration Control of Hydrogen Sulfide 1. Design and Operational Parameters , 1994 .

[10]  J. Devinny,et al.  Evaluation of a two-stage biofilter for treatment of POTW waste air , 1999 .

[11]  A. Lau,et al.  Effects of periods of starvation and fluctuating hydrogen sulfide concentration on biofilter dynamics and performance , 1998 .

[12]  W. Ronald,et al.  SELECTED CHEMOAUTOTROPHIC PROCESSES IN WASTEWATER TREATMENT: LOW TEMPERATURE NITRIFICATION INHIBITION BY AN AZO DYE AND BIOFILTRATION FOR ODOR CONTROL OF HYDROGEN SULFIDE , 2003 .

[13]  M. Deshusses,et al.  Biofiltration for air pollution control , 1998 .

[14]  Hannu Hautakangas,et al.  Optimization of Biofiltration for Odor Control: Model Development and Parameter Sensitivity , 2002, Water environment research : a research publication of the Water Environment Federation.

[15]  J. Kuenen,et al.  C1-cycle of sulfur compounds , 2004, Biodegradation.

[16]  J. Roux,et al.  Biological treatment process of air loaded with an ammonia and hydrogen sulfide mixture. , 2003, Chemosphere.