Aspects of the control of synchronous reluctance machines including saturation and iron losses

The authors consider aspects of the control of synchronous reluctance machines driven from an inverter when the effects of saturation and iron losses are taken into account. The control strategies considered are maximum torque control (i.e. maximum torque per ampere), maximum power factor control, maximum rate of change of torque control, maximum efficiency control, and field weakening control. A general observation about all the strategies considered is that the current angle of operation is usually large, so that the saturation in the D axis inductance is minimal, even for the higher output powers. This indicates that the identification of the saturated values of the L/sub d/ inductance may not be required in a practical controller. The iron loss resistance, on the other hand, plays a crucial role in determining the optimum angles of operation.<<ETX>>

[1]  Robert E. Betz Theoretical aspects of control of synchronous reluctance machines , 1992 .

[2]  R.E. Betz,et al.  Control of synchronous reluctance machines , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[3]  L. Xu,et al.  A compensated vector control scheme of a synchronous reluctance motor including saturation and iron losses , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[4]  X. Xu,et al.  Vector control of a synchronous reluctance motor including saturation and iron loss , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[5]  Antonino Fratta,et al.  Control of a reluctance synchronous motor for spindle applications , 1990 .

[6]  Akira Chiba,et al.  A closed-loop operation of super high-speed reluctance motor for quick torque response , 1992 .