Simulation of Ion-Flow Field at the Crossing of HVDC and HVAC Transmission Lines

This paper aims at developing a simulation method for the ion-flow field when HVDC transmission lines cross over HVAC transmission lines. A time-domain 3-D method is proposed in this paper, where the 3-D finite-element method and 3-D finite volume method are used to solve the Poisson's equation and the charge conservation law, respectively. The implicit temporal discretization scheme is used to accelerate the computation. An indoor test model is set up in this work, and the simulation results agree well with the measured results from this test model, which validates the proposed method. The proposed method is then used to calculate the ground-level electric field and ion current density under the crossing of ± 800-kV HVDC transmission lines and 500-kV HVAC transmission lines. The presence of HVAC transmission lines is found to have a significant influence on the ion-flow field under the crossing.

[1]  X. Cui,et al.  Calculation of the 3-D Ionized Field Under HVDC Transmission Lines , 2011, IEEE Transactions on Magnetics.

[2]  Neil Genzlinger A. and Q , 2006 .

[3]  Tiebing Lu,et al.  Total Electric Field Calculation of Body Model under HVDC Transmission Lines , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[4]  P. S. Maruvada,et al.  Electric Field and Ion Current Environment of HVdc Transmission Lines: Comparison of Calculations and Measurements , 2012, IEEE Transactions on Power Delivery.

[5]  W. Janischewskyj,et al.  Finite Element Solution for Electric Fields of Coronating DC Transmission Lines , 1979, IEEE Transactions on Power Apparatus and Systems.

[6]  P. Sarma Maruvada,et al.  Corona Performance of High Voltage Transmission Lines , 2000 .

[7]  Wasyl Janischewskyj,et al.  Analysis of Corona Losses on DC Transmission Lines Part II - Bipolar Lines , 1969 .

[8]  Stanimire Tomov,et al.  Explicit and Averaging A Posteriori Error Estimates for Adaptive Finite Volume Methods , 2004, SIAM J. Numer. Anal..

[9]  Xiang Cui,et al.  A Time-Efficient Method for the Simulation of Ion Flow Field of the AC-DC Hybrid Transmission Lines , 2012, IEEE Transactions on Magnetics.

[10]  Rong Zeng,et al.  Calculation of the ion flow field of AC-DC hybrid transmission lines , 2009 .

[11]  Tadasu Takuma,et al.  A Very Stable Calculation Method for Ion Flow Field of HVDC Transmission Lines , 1987, IEEE Transactions on Power Delivery.

[12]  Wasyl Janischewskyj,et al.  Analysis of Corona Losses on DC Transmission Lines: I - Unipolar Lines , 1969 .

[13]  Jinliang He,et al.  Finite Volume-Based Approach for the Hybrid Ion-Flow Field of UHVAC and UHVDC Transmission Lines in Parallel , 2011, IEEE Transactions on Power Delivery.

[14]  Stephen A. Sebo,et al.  Calculation of single phase AC and monopolar DC hybrid corona effects , 1996 .

[15]  P. S. Maruvada,et al.  Field and ion interactions of hybrid AC/DC transmission lines , 1988 .

[16]  Tsutomu Ikeda,et al.  Calculation of ION Flow Fields of HVDC Transmission Lines By the Finite Element Method , 1981, IEEE Transactions on Power Apparatus and Systems.

[17]  V.L. Chartier,et al.  Investigation of Corona and Field Effects of AC/DC Hybrid Transmission Lines , 1981, IEEE Transactions on Power Apparatus and Systems.

[18]  Walther Deutsch,et al.  Über die Dichteverteilung unipolarer Ionenströme , 1933 .