Time domain analysis of mutual coupling measurements between stacked patches

The measurement of mutual coupling between stacked patch antennas was performed in presence of distant reflections. Time domain analysis and processing were used for canceling out reflection influence on the measurements. Thus, actual values of measured mutual coupling parameter are obtained. These measurements were used for verification of theoretical model and developed software, where both amplitude and phase of the coupling parameter were compared.