Reliability of predicting image signal-to-noise ratio using noise equivalent count rate in PET imaging.

PURPOSE Several investigators have shown that noise equivalent count rate (NECR) is linearly proportional to the square of image signal-to-noise ratio (SNR) when PET images are reconstructed using filtered back-projection. However, to our knowledge, none have shown a similar relationship in fully 3D ordered-subset expectation maximization (OSEM) reconstruction. This paper has two aims. The first is to investigate the NECR-SNR relationship for 3D-OSEM reconstruction using phantom studies while the second aim is to evaluate the NECR-SNR relationship using patient data. METHODS An anthropomorphic phantom was scanned on a GE Discovery-STE (DSTE) PET∕CT scanner in 3D mode with an initial activity concentration of 66.34 kBq∕cc. PET data were acquired over the lower chest∕upper abdomen region in dynamic mode. The experiment was repeated with the same activity concentration on a GE Discovery-RX (DRX) scanner. Care was taken to place the phantom at identical positions in both scanners. PET data were then reconstructed using 3D Reprojection (3D-RP) and 3D-OSEM with different reconstruction parameters and the NECR and SNR for each frame∕image were calculated. SNR(2) was then plotted versus the NECR for each scanner, reconstruction method and parameters. In addition, 40 clinical PET∕CT studies from the two scanners (20 patients∕scanner) were evaluated retrospectively. The patient studies from each scanner were further divided into two subgroups of body mass indices (BMI). Each PET study was acquired in 3D mode and reconstructed using both 3D-OSEM and 3D-RP. The NECR and SNR of the bed position covering the patient liver were calculated for each patient and averaged for each subgroup. Comparisons of the NECR and SNR between scanner types and BMIs were performed using a t-test and a p value less than 0.05 was considered significant. RESULTS Phantom results showed that SNR(2) versus NECR was linear for 3D-RP reconstruction across all activity concentration on both scanners, as expected. However, when 3D-OSEM was used, this relationship was nonlinear at activity concentrations beyond the peak NECR on both scanners. On the other hand, the plot of SNR(2) versus trues count rate was linear for 3D-OSEM across all activity concentrations on both scanners independent of reconstruction parameters used. In addition, for activity concentrations <30kBq∕cc, phantom results showed a higher SNR (by 12 ± 10%; p < 0.05) and NECR for the DRX scanner compared to DSTE for 3D-RP reconstruction. However, for 3D-OSEM reconstruction, these two scanners had similar SNRs (different by 2% ± 9%; p > 0.05), despite having different NECRs. Patient studies showed a statistically significant difference in NECR as well as the SNR for 3D-RP reconstruction between the two scanners. However, no statistically significant difference was found for 3D-OSEM. A statistically significant difference in both NECR and SNR were found between the different BMI subgroups for both 3D-RP and 3D-OSEM reconstructions. CONCLUSIONS For the scanners and reconstruction algorithm used in this study, our results suggest that the image SNR cannot be predicted by the NEC when using 3D-OSEM reconstruction particularly for those clinical applications requiring high activity concentration. Instead, our results suggest that image SNR varies with activity concentration and is dominated by the 3D-OSEM reconstruction algorithm and its associated parameters, while not being affected by the scanner type for the range of activity concentrations usually found in the clinic.

[1]  Paul Kinahan,et al.  The Theory of Three-Dimensional Image Reconstruction for PET , 1987, IEEE Transactions on Medical Imaging.

[2]  Heiko Schöder,et al.  PET/CT in oncology: integration into clinical management of lymphoma, melanoma, and gastrointestinal malignancies. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  M N Maisey,et al.  Optimization of noise-equivalent count rates in 3D PET. , 1996, Physics in medicine and biology.

[4]  B. Tsui,et al.  Noise properties of the EM algorithm: II. Monte Carlo simulations. , 1994, Physics in medicine and biology.

[5]  C. Watson,et al.  Count rate dependence of local signal-to-noise ratio in positron emission tomography , 2003, IEEE Transactions on Nuclear Science.

[6]  R. Boellaard,et al.  Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  S. Surti,et al.  Count-rate dependent event mispositioning and NEC in PET , 2002, IEEE Transactions on Nuclear Science.

[8]  Stefan Eberl,et al.  Optimizing injected dose in clinical PET by accurately modeling the counting-rate response functions specific to individual patient scans. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  P E Kinahan,et al.  Figures of merit for comparing reconstruction algorithms with a volume-imaging PET scanner. , 1994, Physics in medicine and biology.

[10]  J. Czernin,et al.  Comparison of noise equivalent count rates and image noise , 2005 .

[11]  M. Iatrou,et al.  A fully 3D iterative image reconstruction algorithm incorporating data corrections , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[12]  F. Fazio,et al.  Generation of the Acquisition-Specific NEC (AS-NEC) Curves to Optimize the Injected Dose in 3D$^18$F-FDG Whole Body PET Studies , 2006, IEEE Transactions on Nuclear Science.

[13]  C.C. Watson Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[14]  Yoshiharu Yonekura,et al.  18F-FDG accumulation with PET for differentiation between benign and malignant lesions in the thorax. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Jörg W. Müller Dead-time problems , 1973 .

[16]  Donald W. Wilson,et al.  Noise properties of the EM algorithm. I. Theory , 1994 .

[17]  F. Dehdashti,et al.  Whole-body positron emission tomography: normal variations, pitfalls, and technical considerations. , 1997, AJR. American journal of roentgenology.

[18]  John W. Clark,et al.  Effects of injected dose, BMI and scanner type on NECR and image noise in PET imaging , 2011, Physics in medicine and biology.

[19]  J Llacer,et al.  ROC and LROC analyses of the effects of lesion contrast, size, and signal-to-noise ratio on detectability in PET images. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  R. Badawi,et al.  NEC: some coincidences are more equivalent than others. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  Julian C Matthews,et al.  Optimization of the Injected Activity in Dynamic 3D PET: A Generalized Approach Using Patient-Specific NECs as Demonstrated by a Series of 15O-H2O Scans , 2009, Journal of Nuclear Medicine.

[22]  E. Hoffman,et al.  Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalents counts , 1990 .

[23]  Carole Lartizien,et al.  Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  M. Gilardi,et al.  Noise Equivalent Count Measurements In A Neuro-pet Scanner With Retractable SEPTA , 1990, 1990 IEEE Nuclear Science Symposium Conference Record.

[25]  Charles L. Byrne,et al.  Noise characterization of block-iterative reconstruction algorithms. I. Theory , 2000, IEEE Transactions on Medical Imaging.

[26]  R. Hustinx,et al.  Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose , 1996, European Journal of Nuclear Medicine.

[27]  Paul Kinahan,et al.  Evaluation of noise properties in PSF-based PET image reconstruction , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[28]  Jinyi Qi,et al.  A unified noise analysis for iterative image estimation. , 2003, Physics in medicine and biology.

[29]  Georges El Fakhri,et al.  Impact of Acquisition Geometry, Image Processing, and Patient Size on Lesion Detection in Whole-Body 18F-FDG PET , 2007, Journal of Nuclear Medicine.

[30]  Simon R. Cherry,et al.  NECR analysis of 3D brain PET scanner designs , 1995 .

[31]  S. Surti,et al.  A multiscanner evaluation of PET image quality using phantom studies , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[32]  Val J Lowe,et al.  NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  Performance evaluation of an integrated PET/CT scanner: Discovery STE , 2006 .

[34]  David Brasse,et al.  Correction methods for random coincidences in fully 3D whole-body PET: impact on data and image quality. , 2005, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.