Analysis of pesticides and metabolites in Spanish surface waters by isotope dilution gas chromatography/mass spectrometry with previous automated solid-phase extraction Estimation of the uncertainty of the analytical results.

A method based on isotope dilution gas chromatography/mass spectrometry (GC/MS) with automated solid-phase extraction (SPE) is described for the analysis of 32 pesticides and metabolites in surface waters. This approach consist in the use of nine isotopically labelled representative pesticides as internal standards, which allows high accuracy (trueness and precision) and sensitivity for most analysed compounds, as it is required for isotope dilution-based methods. Uncertainties associated with pesticide determination in real samples were estimated using quality assurance/quality control (QA/QC) data. For most pesticides expanded uncertainty was below 40%, according to the commonly established requirements for analytical results. Ninety three Spanish surface waters collected in June-July and September-November 2004 were analysed. Concentration and occurrence of pesticides were evaluated. These parameters were higher in the summer than in the autumn period. In summer four pesticides were found in more than 50% of the analysed samples and four compounds were detected above the concentration level of 1 microg/l (atrazine, terbutylazine, 3,4-dichloroaniline and fenitrothion), while in autumn percentage of detection was below 50% for all pesticides and only one compound (terbutylazine) exceeded 1 microg/l.

[1]  Leonard Steinborn,et al.  International Organization for Standardization ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories , 2004 .

[2]  F. Borrull,et al.  Solid-phase extraction coupling to capillary electrophoresis with emphasis on environmental analysis. , 2000, Journal of chromatography. A.

[3]  W. Niessen,et al.  Trace-level determination of pesticides in water by means of liquid and gas chromatography. , 2002, Journal of chromatography. A.

[4]  P. Schmitt‐Kopplin,et al.  Analysis of agrochemicals by capillary electrophoresis. , 2000, Journal of chromatography. A.

[5]  J. Caixach,et al.  Analysis of alkyl and 2-6-ringed polycyclic aromatic hydrocarbons by isotope dilution gas chromatography/mass spectrometry. Quality assurance and determination in Spanish river sediments. , 2006, Journal of chromatography. A.

[6]  P. Zoonen,et al.  Trace analysis of pesticides by gas chromatography , 1999 .

[7]  J. Caixach,et al.  Occurrence of pesticides in Spanish surface waters. Analysis by high resolution gas chromatography coupled to mass spectrometry , 1997 .

[8]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[9]  R. Jeannot,et al.  Multiresidue methods using solid-phase extraction techniques for monitoring priority pesticides, including triazines and degradation products, in ground and surface waters. , 2000, Journal of chromatography. A.

[10]  N. Ratola,et al.  Uncertainty associated to the analysis of organochlorine pesticides in water by solid-phase microextraction/gas chromatography-electron capture detection--evaluation using two different approaches. , 2006, Analytica chimica acta.

[11]  F. Ventura,et al.  Monitoring of pesticides in drinking and related waters in NE Spain with a multiresidue SPE-GC-MS method including an estimation of the uncertainty of the analytical results. , 2001, Journal of chromatography. A.

[12]  U. Brinkman,et al.  On-line combination of aqueous-sample preparation and capillary gas chromatography. , 1999, Journal of chromatography. A.

[13]  P. Zoonen,et al.  Recent and future developments of liquid chromatography in pesticide trace analysis. , 2000, Journal of chromatography. A.

[14]  L. Needham,et al.  Application of an improved method for the analysis of pesticides and their metabolites in the urine of farmer applicators and their families , 1996 .

[15]  D. Barr,et al.  A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[16]  F. Hernández,et al.  Solid-phase microextraction in pesticide residue analysis. , 2000, Journal of chromatography. A.