Changes in ultrasonic Doppler backscattered power downstream of concentric and eccentric stenoses under pulsatile flow.

The main objective of the present work was to investigate, under pulsatile flow, the patterns of variation of the Doppler power backscattered by blood and Sephadex particles upstream and downstream of concentric and eccentric stenoses ranging from 47% to 91% area reduction. Doppler measurements were performed at 5 diameters upstream and 5, 10, 15 and 20 diameters downstream of the constriction. For the concentric 75% and 85%, and the eccentric 79% and 91% area reduction stenoses, a progressive increase of the power backscattered by red cell suspensions at 40% hematocrit was measured downstream of the narrowing. The maximal power usually occurred around 10 diameters after the stenosis and dropped further downstream. In addition to the increase in the power, a cyclic variation of the backscattered intensity was observed within the flow cycle. For the concentric 52% and eccentric 47% area reduction stenoses, no variation of the Doppler power was measured during flow acceleration and deceleration for all recording sites. A coefficient of correlation of 0.82 was measured between the percentage of area reduction and the ratio of the Doppler mean power at 10 diameters downstream to that at 5 diameters upstream of the stenoses. Using Sephadex particles at low concentration, no increase of the Doppler power was found downstream of the 85% and 91% area reduction stenoses. The possible link between the intensity of turbulence and the power backscattered by blood is discussed along with the influence of the correlation between the scattering particles, under turbulent flow.

[1]  C Clark,et al.  The propagation of turbulence produced by a stenosis. , 1980, Journal of biomechanics.

[2]  Richard S.C. Cobbold,et al.  Interpretation of power changes in Doppler signals from human blood-in vitro studies , 1988, IEEE 1988 Ultrasonics Symposium Proceedings..

[3]  G Cloutier,et al.  Study of red cell aggregation in pulsatile flow from ultrasonic Doppler power measurements. , 1993, Biorheology.

[4]  D. E. Strandness,et al.  Duplex scanning in vascular disorders , 1990 .

[5]  K. Kirk Shung,et al.  Ultrasonic Scattering Properties of Blood , 1993 .

[6]  V. Twersky,et al.  Polydisperse scattering theory and comparisons with data for red blood cells. , 1991, The Journal of the Acoustical Society of America.

[7]  J. Tarbell,et al.  Effect of flow disturbance on ultrasonic backscatter from blood. , 1984, The Journal of the Acoustical Society of America.

[8]  C. Clark,et al.  Velocity distribution in aortic flow. , 1973, Cardiovascular research.

[9]  H. F. Routh,et al.  Doppler ultrasound , 1996 .

[10]  G. Cloutier,et al.  Cyclic variation of the power of ultrasonic Doppler signals backscattered by polystyrene microspheres and porcine erythrocyte suspensions , 1993, IEEE Transactions on Biomedical Engineering.

[11]  Joseph L. Garbini,et al.  Measurement of fluid turbulence based on pulsed ultrasound techniques. Part 1. Analysis , 1977, Journal of Fluid Mechanics.

[12]  L.-G. Durand,et al.  Comparison of time-frequency distribution techniques for analysis of simulated Doppler ultrasound signals of the femoral artery , 1994, IEEE Transactions on Biomedical Engineering.

[13]  R. Cobbold,et al.  On the Doppler signal from a steady flow asymmetrical stenosis model: effects of turbulence. , 1993, Ultrasound in medicine & biology.

[14]  E. Ritenour Doppler Ultrasound: Physics, Instrumentation and Clinical Applications , 1990 .

[15]  H. Sabbah,et al.  Contribution of erythrocytes to turbulent blood flow. , 1975, Biorheology.

[16]  S Glagov,et al.  The role of fluid mechanics in the localization and detection of atherosclerosis. , 1993, Journal of biomechanical engineering.

[17]  H. Sabbah,et al.  Effect of erythrocytic deformability upon turbulent blood flow. , 1976, Biorheology.

[18]  G. Cloutier,et al.  The effect of turbulence on the variation of the ultrasonic Doppler amplitude within the cardiac cycle , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  H L Falsetti,et al.  Turbulent blood flow in the ascending aorta of dogs. , 1983, Cardiovascular research.

[20]  G. Cloutier,et al.  The effects of hematocrit, shear rate, and turbulence on ultrasonic Doppler spectrum from blood , 1992, IEEE Transactions on Biomedical Engineering.

[21]  V. Twersky,et al.  Low‐frequency scattering by mixtures of correlated nonspherical particles , 1988 .

[22]  H. Akaike A new look at the statistical model identification , 1974 .

[23]  Joseph L. Garbini,et al.  Measurement of fluid turbulence based on pulsed ultrasound techniques. Part 2. Experimental investigation , 1982, Journal of Fluid Mechanics.

[24]  D. F. Young Fluid Mechanics of Arterial Stenoses , 1979 .

[25]  S A Jones,et al.  Fundamental sources of error and spectral broadening in Doppler ultrasound signals. , 1993, Critical reviews in biomedical engineering.

[26]  R S Cobbold,et al.  A comparative study and assessment of Doppler ultrasound spectral estimation techniques. Part II: Methods and results. , 1988, Ultrasound in medicine & biology.