Study on the Thermal Performance of a Hybrid Heat Collecting Facade Used for Passive Solar Buildings in Cold Region

Passive solar technologies are traditionally considered as cost-effective ways for the building heating. However, conventional passive solar buildings are insufficient to create a relatively stable and comfortable indoor thermal environment. To further increase the indoor air temperature and reduce the heating energy consumption, a hybrid heat collecting facade (HHCF) is proposed in this paper. To analyze the thermal performance of the HHCF, a heat transfer model based on the heat balance method is established and validated by experimental results. Meanwhile, the energy saving potential of a room with the HHCF is evaluated as well. When the HHCF is applied to places where heating is required in the cold season while refrigeration is unnecessary in hot season, the HHCF can reduce the heating need by 40.2% and 21.5% compared with the conventional direct solar heat gain window and the Trombe wall, respectively. Furthermore, a series of parametric analyses are performed to investigate the thermal performance of the room with HHCF under various design and operating conditions. It is found that the thermal performance of the HHCF mainly depends on the window operational schedule, the width and the absorptivity of heat collecting wall, and the thermal performance of the inner double-glass window. The modeling and the parametric study in this paper are beneficial to the design and the optimization of the HHCF in passive solar buildings.

[1]  Hongxing Yang,et al.  The application of air layers in building envelopes: A review , 2016 .

[2]  Marta Molina Huelva,et al.  Passive actions in the building envelope to enhance sustainability of schools in a Mediterranean climate , 2019, Energy.

[3]  S. Klein,et al.  An Algorithm for Calculating Monthly-Average Radiation on Inclined Surfaces , 1981 .

[4]  Wolfgang Feist,et al.  Passive Houses for different climate zones , 2015 .

[5]  Roberto Lamberts,et al.  Improvement of a measurement system for solar heat gain through fenestrations , 2007 .

[6]  Moncef Krarti,et al.  Development of a simulation analysis environment for ventilated slab systems , 2015 .

[7]  Mohammad Aminy,et al.  Experiments and simulations on the thermal performance of a sunspace attached to a room including heat-storing porous bed and water tanks , 2015 .

[8]  Xianting Li,et al.  Solar heat gain reduction of double glazing window with cooling pipes embedded in venetian blinds by utilizing natural cooling , 2016 .

[9]  Guobing Zhou,et al.  Experimental investigations on the performance of a collector–storage wall system using phase change materials , 2015 .

[10]  J. C. Lam,et al.  Estimation of obstructed vertical solar irradiation under the 15 CIE Standard Skies , 2016 .

[11]  Moncef Krarti,et al.  Design optimization of energy efficient residential buildings in Tunisia , 2012 .

[12]  Sanja Stevanović,et al.  Optimization of passive solar design strategies: A review , 2013 .

[13]  Z. Choulli,et al.  Improving the passive building energy efficiency through numerical simulation–A case study for Tetouan climate in northern of Morocco , 2018 .

[14]  P. Egolf,et al.  A translucent honeycomb solar collector and thermal storage module for building façades , 2018, International Journal of Heat and Mass Transfer.

[15]  Pascal Henry Biwole,et al.  Passive design optimization of low energy buildings in different climates , 2018, Energy.

[16]  Alfredo Fernández-González Analysis of the thermal performance and comfort conditions produced by five different passive solar heating strategies in the United States midwest , 2007 .

[17]  David Naylor,et al.  Free convection heat transfer from a window glazing with an insect screen , 2017 .

[18]  Zhao Zhiqiang,et al.  Energy and exergy analysis of different Trombe walls , 2016 .

[19]  Yusuf Ali Kara,et al.  Diurnal performance analysis of phase change material walls , 2016 .

[20]  Xing Shi,et al.  Towards adoption of building energy simulation and optimization for passive building design: A survey and a review , 2018 .

[21]  Daisuke Sumiyoshi,et al.  Optimization of passive design measures for residential buildings in different Chinese areas , 2012 .

[22]  Wei Sun,et al.  The thermal behavior of Trombe wall system with venetian blind: An experimental and numerical study , 2015 .

[23]  Jean-Louis Scartezzini,et al.  Passive design optimization of newly-built residential buildings in Shanghai for improving indoor thermal comfort while reducing building energy demand , 2017, Energy and Buildings.

[24]  C. Filippín,et al.  Double skin glazed façades in sunny Mediterranean climates , 2015 .

[25]  Holly Wasilowski Samuelson,et al.  Parametric Energy Simulation in Early Design: High-Rise Residential Buildings in Urban Contexts , 2016 .

[26]  Gustavo Barea,et al.  The multi-azimuthal window as a passive solar system: A study of heat gain for the rational use of energy , 2017 .

[27]  Zhang Ying,et al.  Mathematical Modeling of Double-Skin Facade in Northern Area of China , 2013 .

[28]  Sigrid Reiter,et al.  An investigation on climate responsive design strategies of vernacular housing in Vietnam , 2011 .

[29]  K. A. Antonopoulos,et al.  An innovative Trombe wall as a passive heating system for a building in Athens—A comparison with the conventional Trombe wall and the insulated wall , 2016 .

[30]  Marta Ruiz,et al.  Energy saving in the conventional design of a Spanish house using thermal simulation , 2011 .

[31]  Mustafa Inalli,et al.  Impacts of some building passive design parameters on heating demand for a cold region , 2006 .

[32]  Andreas K. Athienitis,et al.  Assessing active and passive effects of façade building integrated photovoltaics/thermal systems: Dynamic modelling and simulation , 2018 .

[33]  Samar Jaber,et al.  Optimum design of Trombe wall system in mediterranean region , 2011 .

[34]  A. V. Sebald,et al.  Performance effects of Trombe wall control strategies , 1979 .