Bootstrap quantification of cardiac pulsation artifact in DTI

While several studies have shown the benefit of cardiac gating in diffusion MRI with single-shot EPI acquisition, cardiac gating is still not commonly used. This is probably because it requires additional time and many investigators may not be convinced that cardiac gating is worth the extra effort. Here, we tested a clinically feasible protocol with a minimal increase in scan time, and quantified the effect of cardiac gating under partial or full Fourier acquisition. Eight volunteers were scanned on a 3 T scanner with a SENSE 8-channel head coil. Diffusion-weighted, single-shot spin-echo EPI images were acquired along 32 gradient directions, with or without cardiac gating and with partial or full Fourier acquisition. Vectorcardiography (VCG) was used to trigger acquisition at a minimum delay (30 ms). The uncertainties of DTI derived parameters were estimated using residual bootstrap. With partial Fourier, cardiac gating reduced the uncertainties, and better efficiency in reducing DTI parameter variability was also achieved even allowing for the increase in total scan time. For full Fourier acquisition, minimum time gating slightly decreased the uncertainties but the efficiency was worse. A minimum trigger delay might not be the optimal scheme to avoid the majority of systole but it allows clinically acceptable scan times. We have demonstrated that cardiac gating, especially of partial Fourier acquisitions, can reduce the uncertainties of DTI derived parameters in a time-efficient manner.

[1]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[2]  David A Porter,et al.  Reconstruction as a source of artifact in non-gated single-shot diffusion-weighted EPI. , 2005, Magnetic resonance imaging.

[3]  Michaël Sdika,et al.  A Fast Nonrigid Image Registration With Constraints on the Jacobian Using Large Scale Constrained Optimization , 2008, IEEE Transactions on Medical Imaging.

[4]  C H Lorenz,et al.  Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering method , 2000, Journal of magnetic resonance imaging : JMRI.

[5]  Carlo Pierpaoli,et al.  Estimating intensity variance due to noise in registered images: Applications to diffusion tensor MRI , 2005, NeuroImage.

[6]  C. Pierpaoli,et al.  Analyzing the contribution of cardiac pulsation to the variability of quantities derived from the diffusion tensor , 2002 .

[7]  P Boesiger,et al.  Influence of SENSE on image properties in high‐resolution single‐shot echo‐planar DTI , 2006, Magnetic resonance in medicine.

[8]  Peter Jezzard,et al.  Investigations on the efficiency of cardiac-gated methods for the acquisition of diffusion-weighted images. , 2005, Journal of magnetic resonance.

[9]  B. Biswal,et al.  High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels , 2001, Magnetic resonance in medicine.

[10]  S. Skare,et al.  On the effects of gating in diffusion imaging of the brain using single shot EPI. , 2001, Magnetic resonance imaging.

[11]  Roland G. Henry,et al.  Comparison of bootstrap approaches for estimation of uncertainties of DTI parameters , 2006, NeuroImage.

[12]  C. Pierpaoli,et al.  Contribution of Cardiac Pulsation to Variability of Tractography Results , 2005 .

[13]  F. Ståhlberg,et al.  Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imaging , 2004, Neuroradiology.

[14]  V. Wedeen,et al.  Brain parenchyma motion: measurement with cine echo-planar MR imaging. , 1992, Radiology.

[15]  Peter Boesiger,et al.  3D cine displacement‐encoded MRI of pulsatile brain motion , 2009, Magnetic resonance in medicine.

[16]  Brandon Whitcher,et al.  Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging , 2008, Human brain mapping.

[17]  Peter Boesiger,et al.  Assessment of human brain motion using CSPAMM , 2007, Journal of magnetic resonance imaging : JMRI.

[18]  C H Lorenz,et al.  Novel real‐time R‐wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions , 1999, Magnetic resonance in medicine.

[19]  S. Brockstedt,et al.  Triggering in Quantitative Diffusion Imaging with Single-Shot EPI , 1999, Acta radiologica.