Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage.

BACKGROUND The introduction of optical coherence tomography (OCT) as an intracoronary imaging modality has allowed accurate assessment of strut apposition and neointimal tissue coverage. This study set out to assess the inter and intraobserver variability of measurements of acute stent apposition and strut tissue coverage using OCT. METHODS Thirty patients were studied (14 immediately after stent implantation and 16 during follow-up angiography [mean of 4.7+/-2.8 months]) using OCT (LightLab, Westford, Massachusetts, US). Data analysis was performed by 2 experienced observers. Struts were classified as "embedded", "protruding" or "malapposed" to the vessel well and recorded as percentage of total struts. Intimal coverage at follow-up was measured as the thickness of tissue covering each strut expressed in mum. Intra and interobserver variability was assessed by Bland-Altman plots and by calculation of the intraclass correlation coefficient (ICC). RESULTS An average of 3967 struts was examined by each observer and, overall, 53.7% of struts was embedded, 36.4% protruding and 9.9% malapposed. Low intraobserver variability for all measures of strut apposition was found, with repeatability coefficients that ranged between 5.1% and 9.3% and ICC exceeding 95% in all cases. Interobserver variability was also low (repeatability coefficients 6.6-10.8 and ICC>91.3%). Mean intimal thickness in the follow-up group was 172.5 microm. Bland-Altman plots demonstrated a low intraobserver and interobserver variability for intimal thickness, with repeatability coefficients 26.7 mum and 24.1 mum, respectively and ICC exceeding 98.6% for both. CONCLUSIONS Low intra and interobserver variability can be expected when analyzing OCT data for stent apposition and tissue coverage. This supports the validity of OCT as a clinical and research tool in the setting of intracoronary stent imaging.

[1]  E. Halpern,et al.  Quantification of Macrophage Content in Atherosclerotic Plaques by Optical Coherence Tomography , 2003, Circulation.

[2]  Seung‐Jung Park,et al.  Late Stent Malapposition After Drug-Eluting Stent Implantation: An Intravascular Ultrasound Analysis With Long-Term Follow-Up , 2006, Circulation.

[3]  Rolf Vogel,et al.  Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation , 2007, Circulation.

[4]  A. Coats,et al.  Ethical authorship and publishing. , 2009, International journal of cardiology.

[5]  B. Bouma,et al.  Optical coherence tomography for imaging the vulnerable plaque. , 2006, Journal of biomedical optics.

[6]  J. Tanigawa,et al.  Coronary bioabsorbable magnesium stent: 15-month intravascular ultrasound and optical coherence tomography findings. , 2007, European heart journal.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  Brett E Bouma,et al.  Optical coherence tomography as a tool for percutaneous coronary interventions , 2005, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  Hiromasa Otake,et al.  Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. , 2007, European heart journal.

[10]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[11]  Stéphane G Carlier,et al.  Clinical researchInterventional cardiologyStent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study , 2005 .

[12]  P. Serruys,et al.  Incomplete Stent Apposition After Implantation of Paclitaxel-Eluting Stents or Bare Metal Stents: Insights From the Randomized TAXUS II Trial , 2005, Circulation.

[13]  E. Halpern,et al.  Evaluation of intracoronary stenting by intravascular optical coherence tomography , 2003, Heart.

[14]  Brett E Bouma,et al.  Relationship Between a Systemic Inflammatory Marker, Plaque Inflammation, and Plaque Characteristics Determined by Intravascular Optical Coherence Tomography , 2007, Arteriosclerosis, thrombosis, and vascular biology.

[15]  Peter Barlis,et al.  Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. , 2007, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[16]  J. Tanigawa,et al.  Optical coherence tomography to assess malapposition in overlapping drug-eluting stents. , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[17]  Patrick W Serruys,et al.  A novel approach for quantitative analysis of intracoronary optical coherence tomography: High inter‐observer agreement with computer‐assisted contour detection , 2008, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[18]  Masanori Yamamoto,et al.  Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. , 2007, The American journal of cardiology.

[19]  Brett E. Bouma,et al.  In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography , 2005, Circulation.

[20]  A. Yeung,et al.  Predictors and outcomes of stent thrombosis: an intravascular ultrasound registry. , 2002, European heart journal.

[21]  Michael Joner,et al.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. , 2006, Journal of the American College of Cardiology.

[22]  Takashi Akasaka,et al.  Assessment of culprit lesion morphology in acute myocardial infarction: ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. , 2007, Journal of the American College of Cardiology.