Dynamic k‐space filling for bolus chase 3D MR digital subtraction angiography

A bolus chase three‐dimensional (3D) MR digital subtraction angiography (MRDSA) technique was implemented using dynamic k‐space filling. This technique permits rapid 3D arterial imaging of the entire lower extremity at multiple stations using a single intravenous injection. Image acquisition at the first (most proximal) station starts from the edge of k‐space and ends in the center of k‐space (edge‐center order). Image acquisition for middle stations starts from the edge of k‐space, arrives at the center of k‐space at the middle of data acquisition, and ends at the edge of k‐space (edge‐center‐edge order). Image acquisition for the last station starts from the center of k‐space and ends at the edge of k‐space (center‐edge order). This dynamic k‐space filling minimizes contrast dose and motion artifacts. Bolus chase 3D MRDSA was performed on four normal volunteers and three patients using a multiple‐phase 3D fast gradient‐echo sequence, 25‐ml gadolinium dose, and a prototype stepping table. Total bolus chase 3D acquisition time was 46 s. Mask subtraction using both complex and magnitude subtraction was performed. Complex subtraction was found to be necessary for proper delineation of arteries below the aortic bifurcation. Diagnostic results were consistently obtained for all subjects.

[1]  G C McKinnon,et al.  Breath-hold, contrast-enhanced, three-dimensional MR angiography. , 1996, Radiology.

[2]  A. Shetty,et al.  Contrast-enhanced three-dimensional MR angiography in a single breath-hold: a novel technique. , 1995, AJR. American journal of roentgenology.

[3]  Y. Wang,et al.  Bolus-chase MR digital subtraction angiography in the lower extremity. , 1998, Radiology.

[4]  T. Chenevert,et al.  Breath-hold gadolinium-enhanced MR angiography of the abdominal aorta and its major branches. , 1995, Radiology.

[5]  D. L. Johnston,et al.  Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction , 1996, Magnetic resonance in medicine.

[6]  P. Douek,et al.  Fast MR angiography of the aortoiliac arteries and arteries of the lower extremity: value of bolus-enhanced, whole-volume subtraction technique. , 1995, AJR. American journal of roentgenology.

[7]  W. J. Matchett,et al.  Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography. , 1996, Radiology.

[8]  Matthew S. Johnson,et al.  Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold. , 1996, Radiology.

[9]  R Frayne,et al.  Time‐resolved contrast‐enhanced 3D MR angiography , 1996, Magnetic resonance in medicine.

[10]  M. Prince Gadolinium-enhanced MR aortography. , 1990, Radiology.

[11]  R. Edelman,et al.  Dynamic contrast-enhanced subtraction MR angiography of the lower extremities: initial evaluation with a multisection two-dimensional time-of-flight sequence. , 1995, Radiology.

[12]  S J Riederer,et al.  Improved centric phase encoding orders for three‐dimensional magnetization‐prepared mr angiography , 1996, Magnetic resonance in medicine.

[13]  Y. Wang,et al.  Timing algorithm for bolus chase MR digital subtraction angiography , 1998, Magnetic resonance in medicine.

[14]  L. Axel,et al.  Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries. , 1996, AJR. American journal of roentgenology.

[15]  Klaus Scheffler,et al.  Time‐resolved projection angiography after bolus injection of contrast agent , 1997, Magnetic resonance in medicine.