Use of robotic technology for diathrodial joint research.

Knowledge of diarthrodial joint mechanics and specific function of the ligaments are needed in order to understand injury mechanisms, improve surgical procedures and design better post-surgical rehabilitation protocols. To facilitate these needs, a robotic/universal force-moment sensor (UFS) testing system was developed to measure joint kinematics in multiple degree-of-freedom and the in situ forces in the ligaments. When operated in the position control mode, the testing system applies a known load to the intact joint while the motion and force data are recorded. After transection of a ligament, the recorded motion for the intact joint is repeated and new force and moment data is recorded by the UFS. Since the robot reproduces the identical initial position as well as path of joint motion before and after a ligament is transected, the in situ force in the ligament is the difference between the two sets of force and moment data. In force control mode, a known force is applied to the intact knee while the kinematics are recorded. After ligament transection, the same force is applied while the changes in kinematics are again recorded. Testing in this mode is similar to a clinical examination that diagnoses ligament injury. To date, this testing system has been used for experimental studies that examine the anterior cruciate ligament & posterior cruciate ligament of the knee and ligaments of the shoulder. A three-dimensional finite element model has also been constructed based on CT/MRI scans of a knee specimen and validated using data obtained with the testing system. Once in vivo kinematics (such as during gait analysis or throwing activities) are available, the robotic/UFS testing system can be programmed to reproduce these joint kinematics on young human cadaveric specimens in order to generate a database for in situ forces in the ligaments, or Ligament replacement grafts. With appropriate computational models, the stresses and strains in these tissues in vivo can also be determined. Potential applications of this combined approach include pre-operative surgical planning, improvement of surgical procedures as well as development of appropriate post-operative rehabilitation protocols.

[1]  F. Girgis,et al.  The cruciate ligaments of the knee joint. Anatomical, functional and experimental analysis. , 1975, Clinical orthopaedics and related research.

[2]  Freddie H. Fu,et al.  Determination of the in situ loads on the human anterior cruciate ligament , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  R. Warren,et al.  The role of the posterolateral and cruciate ligaments in the stability of the human knee. A biomechanical study. , 1987, The Journal of bone and joint surgery. American volume.

[4]  Freddie H. Fu,et al.  In situ forces in the anterior cruciate ligament and its bundles in response to anterior tibial loads , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  K. Miyasaka The incidece of knee ligament injuries in the general population , 1991 .

[6]  Freddie H. Fu,et al.  Contribution of the passive properties of the rotator cuff to glenohumeral stability during anterior-posterior loading. , 1999, Journal of shoulder and elbow surgery.

[7]  T W Rudy,et al.  Effect of combined axial compressive and anterior tibial loads on in situ forces in the anterior cruciate ligament: A porcine study , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  G A Livesay,et al.  The use of a universal force-moment sensor to determine in-situ forces in ligaments: a new methodology. , 1995, Journal of biomechanical engineering.

[9]  Freddie H. Fu,et al.  The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: evaluation using a robotic testing system. , 1997, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[10]  S. Woo,et al.  Determination of the In Situ Forces in the Human Posterior Cruciate Ligament Using Robotic Technology , 1998, The American journal of sports medicine.

[11]  Cyril B. Frank,et al.  Ligament Healing: Current Knowledge and Clinical Applications , 1996, The Journal of the American Academy of Orthopaedic Surgeons.

[12]  F E Zajac,et al.  Using cine phase contrast magnetic resonance imaging to non-invasively study in vivo knee dynamics. , 1997, Journal of biomechanics.

[13]  P. Aglietti,et al.  Arthroscopic-assisted anterior cruciate ligament reconstruction with the central third patellar tendon A 5–8-year follow-up , 1997, Knee Surgery, Sports Traumatology, Arthroscopy.

[14]  H Fujie,et al.  Forces and moments in six-DOF at the human knee joint: mathematical description for control. , 1996, Journal of biomechanics.

[15]  A J van den Bogert,et al.  A method to determine bone movement in the ankle joint complex in vitro. , 1997, Journal of biomechanics.

[16]  G. Mann,et al.  Secondary damage to the knee after isolated injury of the anterior cruciate ligament , 1990, The American journal of sports medicine.

[17]  T P Andriacchi,et al.  A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. , 1998, Journal of biomechanical engineering.

[18]  S. Woo,et al.  The Effects of a Popliteus Muscle Load on In Situ Forces in the Posterior Cruciate Ligament and on Knee Kinematics , 1998, The American journal of sports medicine.

[19]  P R Cavanagh,et al.  Three-dimensional kinematics of the human knee during walking. , 1992, Journal of biomechanics.

[20]  F. Noyes,et al.  Limits of movement in the human knee. Effect of sectioning the posterior cruciate ligament and posterolateral structures. , 1988, The Journal of bone and joint surgery. American volume.

[21]  R. Parker,et al.  Graft Selection in Anterior Cruciate Ligament Revision Surgery , 1996, Clinical orthopaedics and related research.

[22]  G A Livesay,et al.  A combined robotic/universal force sensor approach to determine in situ forces of knee ligaments. , 1996, Journal of biomechanics.

[23]  S. Woo,et al.  Assessment of Posterior Cruciate Ligament Graft Performance Using Robotic Technology , 1996, The American journal of sports medicine.

[24]  S. Woo,et al.  The forces in the anterior cruciate ligament and knee kinematics during a simulated pivot shift test: A human cadaveric study using robotic technology. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[25]  S. Woo,et al.  Effects of sectioning the posterolateral structures on knee kinematics and in situ forces in the posterior cruciate ligament , 2000, Knee Surgery, Sports Traumatology, Arthroscopy.

[26]  K. H. Chan,et al.  In‐vitro ligament tension pattern in the flexed knee in passive loading , 1987, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.