Excessive Crossed Disparity Detection by Visual Evoked Potentials to Reduce Visual Discomfort in 3D Viewing

As excessive crossed disparity is known to cause visual discomfort, this study aims to establish a classification model to discriminate excessive crossed disparity in stereoscopic viewing in combination with subjective assessment of visual discomfort. A stereo-visual evoked potentials (VEPs) experimental system was built up to obtain the VEPs evoked by stereoscopic stimulus with different disparities. Ten volunteers participated in this experiment, and forty VEP datasets in total were extracted when the viewers were under comfortable viewing conditions. Six features of VEPs from three electrodes at the occipital lobe were chosen, and the classification was established using the Fisher's linear discriminant (FLD). Based on FLD results, the correct rate for determining the excessive crossed disparity was 70%, and it reached 80% for other stimuli. The study demonstrated cost-effective discriminant classification modelling to distinguish the stimulus with excessive crossed disparity which inclines to cause visual discomfort.

[1]  J. Kuze,et al.  Subjective evaluation of visual fatigue caused by motion images , 2008, Displays.

[2]  Sumio Yano,et al.  A study of visual fatigue and visual comfort for 3D HDTV/HDTV images , 2002 .

[3]  Qisheng Ding,et al.  Single-Trial Estimation of Evoked Potential Signals via ARX Model and Sparse Coding , 2017 .

[4]  Sang Hyun Kim,et al.  Evaluation Model of the Visual Fatigue on the 3D Stereoscopic Video , 2016 .

[5]  Yue Gong,et al.  Stereoscopic visual fatigue assessment and modeling , 2014, Electronic Imaging.

[6]  Bernhard Moser,et al.  Improving Visual Discomfort Prediction for Stereoscopic Images via Disparity-based Contrast , 2016 .

[7]  Mtm Marc Lambooij,et al.  Visual Discomfort and Visual Fatigue of Stereoscopic Displays: A Review , 2009 .

[8]  Min-Chul Park,et al.  SSVEP and ERP measurement of cognitive fatigue caused by stereoscopic 3D , 2012, Neuroscience Letters.

[9]  Kwanghoon Sohn,et al.  Depth adjustment for stereoscopic image using visual fatigue prediction and depth-based view synthesis , 2010, 2010 IEEE International Conference on Multimedia and Expo.

[10]  Yongtian Wang,et al.  EEG-Based Assessment of Stereoscopic 3D Visual Fatigue Caused by Vergence-Accommodation Conflict , 2015, Journal of Display Technology.

[11]  Qiong-hua Wang,et al.  Survey on stereoscopic three-dimensional display: Survey on stereoscopic three-dimensional display , 2010 .

[12]  Uma Shahani,et al.  Neural and vascular responses to fused binocular stimuli: a VEP and fNIRS study. , 2012, Investigative ophthalmology & visual science.

[13]  Xiaowei Li,et al.  Wavelet-based iterative perfect reconstruction in computational integral imaging. , 2018, Journal of the Optical Society of America. A, Optics, image science, and vision.

[14]  Mahmoud Boudiaf,et al.  Denoising of single-trial event-related potentials using adaptive modelling , 2017, IET Signal Process..

[15]  Shiro Suyama Recent 3D technology in our laboratory : 3D technologies proposed and developed in our lab. & Problems in 3D technology , 2012 .

[16]  Jérémy Frey,et al.  Classifying EEG Signals during Stereoscopic Visualization to Estimate Visual Comfort , 2015, Comput. Intell. Neurosci..

[17]  Rassoul Amirfattahi,et al.  Wavelet based single trial Event Related Potential extraction in very low SNR conditions , 2016, 2016 6th International Conference on Computer and Knowledge Engineering (ICCKE).

[18]  Mei Yu,et al.  New stereo visual comfort assessment method based on scene mode classification , 2015, 2015 Seventh International Workshop on Quality of Multimedia Experience (QoMEX).

[19]  I. Heynderickx,et al.  Measuring visual discomfort associated with 3D displays , 2009, Electronic Imaging.

[20]  Ando Hiroshi,et al.  VEP Evaluation Method of Visual Fatigue in Observation of 3D Display , 2012 .

[21]  Three-dimensional display-induced transient myopia and the difference in myopic shift between crossed and uncrossed disparities. , 2012, Investigative ophthalmology & visual science.

[22]  Doris Y. Tsao,et al.  Stereopsis Activates V3A and Caudal Intraparietal Areas in Macaques and Humans , 2003, Neuron.

[23]  David M. Hoffman,et al.  The zone of comfort: Predicting visual discomfort with stereo displays. , 2011, Journal of vision.

[24]  Yong Man Ro,et al.  Towards a Physiology-Based Measure of Visual Discomfort: Brain Activity Measurement While Viewing Stereoscopic Images With Different Screen Disparities , 2015, Journal of Display Technology.

[25]  Yong Man Ro,et al.  Predicting Visual Discomfort Using Object Size and Disparity Information in Stereoscopic Images , 2013, IEEE Transactions on Broadcasting.

[26]  Jun Zhou,et al.  Visual discomfort prediction on stereoscopic 3D images without explicit disparities , 2017, Signal Process. Image Commun..

[27]  Yong Man Ro,et al.  fMRI analysis of excessive binocular disparity on the human brain , 2014, Int. J. Imaging Syst. Technol..

[28]  D. Finlay,et al.  Detection threshold differences to crossed and uncrossed disparities , 1987, Vision Research.