A T-Connected Transformer and Three-leg VSC Based DSTATCOM for Power Quality Improvement

In this paper, a new three-phase four-wire distribution static compensator (DSTATCOM) based on a T-connected transformer and a three-leg voltage source converter (VSC) is proposed for power quality improvement. The T-connected transformer connection mitigates the neutral current and the three-leg VSC compensates harmonic current, reactive power, and balances the load. Two single-phase transformers are connected in T-configuration for interfacing to a three-phase four-wire power distribution system and the required rating of the VSC is reduced. The insulated gate bipolar transistor (IGBT) based VSC is supported by a capacitor and is controlled for the required compensation of the load current. The DC bus voltage of the VSC is regulated during varying load conditions. The DSTATCOM is tested for power factor correction and voltage regulation along with neutral current compensation, harmonic elimination, and balancing of linear loads as well as nonlinear loads. The performance of the three-phase four-wire DSTATCOM is validated using MATLAB software with its Simulink and power system blockset toolboxes.

[1]  Timothy J. E. Miller,et al.  Design of Brushless Permanent-Magnet Motors , 1994 .

[2]  Bhim Singh,et al.  A Novel T-Connected Autotransformer-Based 18-Pulse AC–DC Converter for Harmonic Mitigation in Adjustable-Speed Induction-Motor Drives , 2007, IEEE Transactions on Industrial Electronics.

[3]  Antonio Moreno-Munoz,et al.  Power quality : mitigation technologies in a distributed environment , 2007 .

[4]  Hurng-Liahng Jou,et al.  Novel power converter topology for threephase four-wire hybrid power filter , 2008 .

[5]  Prasad Enjeti,et al.  Analysis and design of a new active power filter to cancel neutral current harmonics in three phase four wire electric distribution systems , 1993, Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting.

[6]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[7]  Kamal Al-Haddad,et al.  Design, simulation and implementation of three-pole/four-pole topologies for active filters , 2004 .

[8]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[9]  Hurng-Liahng Jou,et al.  A Three-Phase Four-Wire Power Filter Comprising a Three-Phase Three-Wire Active Power Filter and a Zig–Zag Transformer , 2008, IEEE Transactions on Power Electronics.

[10]  Michel. edited by Michel Crappe. Crappe,et al.  Electric power systems , 2008 .

[11]  Shahrokh Saadate,et al.  New control approach for four-wire active power filter based on the use of synchronous reference frame , 2005 .

[12]  Hirofumi Akagi,et al.  Instantaneous power theory and applications to power conditioning , 2007 .

[13]  Subhashish Bhattacharya,et al.  Synchronous frame based controller implementation for a hybrid series active filter system , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[14]  H. Fujita,et al.  Voltage-Regulation Performance of a Shunt Active Filter Intended for Installation on a Power Distribution System , 2007, IEEE Transactions on Power Electronics.

[15]  Arindam Ghosh,et al.  Power Quality Enhancement Using Custom Power Devices , 2002 .

[16]  B. A. Cogbill,et al.  Analysis of T-T Connections of Two Single-Phase Transformers , 1968 .

[17]  Hurng-Liahng Jou,et al.  Analysis of zig-zag transformer applying in the three-phase four-wire distribution power system , 2005 .