First Animal Cadaver Study for Interlocking of Intramedullary Nails under Camera Augmented Mobile C-arm

The Camera Augmented Mobile C-arm (CamC) system that augments a regular mobile C-arm by a video camera provides an overlay image of X-ray and video. This technology is expected to reduce radiation exposure during surgery without introducing major changes to the standard surgical workflow. Whereas many experiments were conducted to evaluate the technical characteristics of the CamC system, its clinical performance has not been investigated in detail. In this work, a workflow based method is proposed and applied to evaluate the clinical impact of the CamC system by comparing its performance with a conventional system, i.e. standard mobile C-arm. Interlocking of intramedullary nails on animal cadaver is chosen as a simulated clinical model for the evaluation study. Analyzing single workflow steps not only reveals individual strengths and weaknesses related to each step, but also allows surgeons and developers to be involved intuitively to evaluate and have an insight into the clinical impact of the system. The results from a total of 20 pair cases, i.e. 40 procedures, performed by 5 surgeons show that it takes significantly less radiation exposure whereas operation time for the whole interlocking procedure and quality of the drilling result are similar, using the CamC system compared to using the standard mobile C-arm. Moreover, the workflow based evaluation reveals in which surgical steps the CamC system has its main impact.

[1]  T. Neumuth,et al.  Title Validation of Knowledge Acquisition for Surgical Process Models Authors , 2009 .

[2]  Ivan Zuna,et al.  Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. A prospective, controlled clinical study. , 2004, Injury.

[3]  Nassir Navab,et al.  Camera Augmented Mobile C-Arm (CAMC): Calibration, Accuracy Study, and Clinical Applications , 2010, IEEE Transactions on Medical Imaging.

[4]  Nassir Navab,et al.  Visual marker detection and decoding in AR systems: a comparative study , 2002, Proceedings. International Symposium on Mixed and Augmented Reality.

[5]  Nassir Navab,et al.  Merging visible and invisible: two Camera-Augmented Mobile C-arm (CAMC) applications , 1999, Proceedings 2nd IEEE and ACM International Workshop on Augmented Reality (IWAR'99).

[6]  Nadine Warzée,et al.  A Novel Technique for Distal Locking of Intramedullary Nail Based on Two Non-constrained Fluoroscopic Images and Navigation , 2008, IEEE Transactions on Medical Imaging.

[7]  K. Cleary,et al.  Image-guided interventions : technology and applications , 2008 .

[8]  B. Wall,et al.  Revised radiation doses for typical X-ray examinations. Report on a recent review of doses to patients from medical X-ray examinations in the UK by NRPB. National Radiological Protection Board. , 1997, The British journal of radiology.

[9]  T. Neumuth,et al.  Structured recording of intraoperative surgical workflows , 2006, SPIE Medical Imaging.

[10]  Henry I. Kohn,et al.  Health Effects of Exposure to Low Levels of Ionizing Radiation (BEIR V) , 1990 .

[11]  Division on Earth Health Effects of Exposure to Low Levels of Ionizing Radiation: BEIR V , 1990 .

[12]  K. Cleary,et al.  Image Guided Interventions. , 2020, Biomedizinische Technik. Biomedical engineering.

[13]  Lejing Wang,et al.  Workflow Based Assessment of the Camera Augmented Mobile Carm System , 2008 .

[14]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[15]  Lejing Wang,et al.  Camera Augmented Mobile C-arm , 2009, Bildverarbeitung für die Medizin.

[16]  Leo Joskowicz,et al.  Precise robot-assisted guide positioning for distal locking of intramedullary nails , 2005, IEEE Transactions on Medical Imaging.