The "millipede" - nanotechnology entering data storage

Present a new scanning-probe-based data-storage concept called the "millipede" that combines ultrahigh density, terabit capacity, small form factor, and high data rate. Ultrahigh storage density has been demonstrated by a new thermomechanical local-probe technique to store, read back, and erase data in very thin polymer films. With this new technique, nanometer-sized bit indentations and pitch sizes have been made by a single cantilever/tip into thin polymer layers, resulting in a data storage densities of up to 1 Tb/in/sup 2/. High data rates are achieved by parallel operation of large two-dimensional (2-D) atomic force microscope (AFM) arrays that have been batch-fabricated by silicon surface-micromachining techniques. The very large-scale integration (VLSI) of micro/nanomechanical devices (cantilevers/tips) on a single chip leads to the largest and densest 2-D array of 32/spl times/32 (1024) AFM cantilevers with integrated write/read/erase storage functionality ever built. Time-multiplexed electronics control the functional storage cycles for parallel operation of the millipede array chip. Initial areal densities of 100-200 Gb/in/sup 2/ have been achieved with the 32/spl times/32 array chip.

[1]  M. Huggins Viscoelastic Properties of Polymers. , 1961 .

[2]  H. Cantow Properties of polymers , 1980 .

[3]  T. Ravi,et al.  Oxidation sharpening of silicon tips , 1991 .

[4]  D. Rugar,et al.  Thermomechanical writing with an atomic force microscope tip , 1992 .

[5]  Robert C. Barrett,et al.  High-density data storage using proximal probe techniques , 1995, IBM J. Res. Dev..

[6]  J. Weese,et al.  Viscoelastic Properties of Narrow-Distribution Poly(methyl methacrylates) , 1996 .

[7]  E. Grochowski,et al.  Future trends in hard disk drives , 1996 .

[8]  L. Fan,et al.  6-MHz 2-N/m piezoresistive atomic-force microscope cantilevers with INCISIVE tips , 1997 .

[9]  T. Kenny,et al.  Micromachined heaters with 1-/spl mu/s thermal time constants for AFM thermomechanical data storage , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[10]  Peter Vettiger,et al.  High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS , 1998 .

[11]  C. Quate,et al.  AUTOMATED PARALLEL HIGH-SPEED ATOMIC FORCE MICROSCOPY , 1998 .

[12]  D. M. Freeman,et al.  Using a light microscope to measure motions with nanometer accuracy , 1998 .

[13]  B. Terris,et al.  Atomic force microscope-based data storage: track servo and wear study , 1998 .

[14]  M. Lutwyche,et al.  Microfabrication and parallel operation of 5/spl times/5 2D AFM cantilever arrays for data storage and imaging , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[15]  W. Häberle,et al.  Ultrahigh density, high-data-rate NEMS-based AFM data storage system , 1999 .

[16]  Ute Drechsler,et al.  Planar micromagnetic X/Y/Z scanner with five degrees of freedom , 1999 .

[17]  B. Terris,et al.  High-density data storage based on the atomic force microscope , 1999, Proc. IEEE.

[18]  Ute Drechsler,et al.  5×5 2D AFM cantilever arrays a first step towards a Terabit storage device , 1999 .

[19]  W. Häberle,et al.  VLSI-NEMS chip for AFM data storage , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[20]  Thomas W. Kenny,et al.  Ultrahigh-density atomic force microscopy data storage with erase capability , 1999 .

[21]  T. Kenny,et al.  Modeling and Prediction of Sub-Micrometer Heat Transfer During Thermomechanical Data Storage , 1999, Micro-Electro-Mechanical Systems (MEMS).

[22]  Dürig,et al.  The “ Millipede ” — More than one thousand tips for future AFM data storage , 2000 .

[23]  Ute Drechsler,et al.  Highly parallel data storage system based on scanning probe arrays , 2000 .

[24]  W. Häberle,et al.  Fabrication of a micromachined magnetic X/Y/Z scanner for parallel scanning probe applications , 2000 .

[25]  W. Häberle,et al.  VLSI-NEMS chip for parallel AFM data storage , 2000 .

[26]  D. A. Thompson,et al.  The Future of Magnetic Data Storage Technology , 2000 .

[27]  Jong Up Jeon,et al.  Electromagnetic Micro x-y Stage for Probe-Based Data Storage , 2001 .

[28]  Thomas W. Kenny,et al.  Design of atomic force microscope cantilevers for combined thermomechanical writing and thermal reading in array operation , 2002 .