Two-Terminal Traveling-Wave-Based Transmission-Line Protection

This paper proposes a two-terminal traveling-wave-based transmission-line protection using only the first wavefront arrival time at each line terminal (polarity and magnitude of transients are not required), leading to a simple, accurate, and fast protection. In real time, the protection system detects internal and external faults and identifies the fault directionality. In addition, the protection zone and the protection operating time are also formulated. The effects of the sampling rate and the traveling-wave propagation velocity estimation are considered, and some paradigms, such as the need of a high-sampling frequency and an accurate traveling-wave propagation velocity estimation are properly addressed. Two traveling-wave-based protective relays were implemented and evaluated in realistic real-time hardware-in-the-loop simulations considering the communication equipment between the relays, in which reliability and protection operating time could be assessed accordingly.

[1]  Jiali He,et al.  Surge impedance relay , 2005 .

[2]  M. Gilany,et al.  Traveling-Wave-Based Fault-Location Scheme for Multiend-Aged Underground Cable System , 2007, IEEE Transactions on Power Delivery.

[3]  M. Sanaye-Pasand,et al.  A Traveling-Wave-Based Protection Technique Using Wavelet/PCA Analysis , 2010, IEEE Transactions on Power Delivery.

[4]  Jeremy S. Smith,et al.  Morphological undecimated wavelet decomposition for fault location on power transmission lines , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[5]  Apostolos N. Milioudis,et al.  Detection and Location of High Impedance Faults in Multiconductor Overhead Distribution Lines Using Power Line Communication Devices , 2015, IEEE Transactions on Smart Grid.

[6]  W. C. Santos,et al.  Real-Time Detection of Transients Induced by High-Impedance Faults Based on the Boundary Wavelet Transform , 2015, IEEE Transactions on Industry Applications.

[7]  Mario Oleskovicz,et al.  Combined solution for fault location in three-terminal lines based on wavelet transforms , 2010 .

[8]  G. Swift,et al.  The Spectra of Fault-Induced Transients , 1979, IEEE Transactions on Power Apparatus and Systems.

[9]  Irene Yu-Hua Gu,et al.  Signal processing of power quality disturbances , 2006 .

[10]  B.D. Russell,et al.  High impedance fault detection for industrial power systems , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.

[11]  Z. Q. Bo,et al.  A new non-communication protection technique for transmission lines , 1998 .

[12]  Arthur Wright,et al.  Scheme, based on travelling-waves, for the protection of major transmission lines , 1988 .

[13]  M. Kezunovic,et al.  Transmission Line Boundary Protection Using Wavelet Transform and Neural Network , 2007, IEEE Transactions on Power Delivery.

[14]  A. T. Johns,et al.  A Novel Fault Detection Techique of High Impedance Arcing Faults in Transmission Lines Using the Wavelet Transform , 2002, IEEE Power Engineering Review.

[15]  D. Fernandes,et al.  Real-Time Traveling-Wave-Based Fault Location Using Two-Terminal Unsynchronized Data , 2015, IEEE Transactions on Power Delivery.

[16]  F. B. Costa,et al.  Effects of the fault inception angle in fault-induced transients , 2012 .

[17]  F. V. Lopes,et al.  A Traveling-Wave Detection Method Based on Park's Transformation for Fault Locators , 2013, IEEE Transactions on Power Delivery.

[18]  O. P. Malik,et al.  Study of Wavelet-Based Ultra-High-Speed Directional Transmission Line Protection , 2002, IEEE Power Engineering Review.

[19]  Edmund O. Schweitzer,et al.  Performance of time-domain line protection elements on real-world faults , 2016, 2016 69th Annual Conference for Protective Relay Engineers (CPRE).

[20]  F. B. Costa,et al.  Boundary Wavelet Coefficients for Real-Time Detection of Transients Induced by Faults and Power-Quality Disturbances , 2014, IEEE Transactions on Power Delivery.

[21]  Zhiguo Hao,et al.  Study of Ultra-High-Speed Protection of Transmission Lines Using a Directional Comparison Scheme of Transient Energy , 2015, IEEE Transactions on Power Delivery.

[22]  A. T. Johns,et al.  New ultra-high-speed directional comparison technique for the protection of e.h.v. transmission lines , 1980 .

[23]  P. Crossley,et al.  Distance Protection Based on Travelling Waves , 1983, IEEE Transactions on Power Apparatus and Systems.

[24]  Flavio B. Costa Fault-Induced Transient Detection Based on Real-Time Analysis of the Wavelet Coefficient Energy , 2014 .

[25]  F. B. Costa,et al.  Real-time detection of fault-induced transients in transmission lines , 2010 .

[26]  Athula D. Rajapakse,et al.  Design and hardware implementation of a modular transient directional protection scheme using current signals , 2012 .

[27]  Sang-Hee Kang,et al.  Verification of the Wavelet-Based HIF Detecting Algorithm Performance in Solidly Grounded MV Networks , 2007, IEEE Transactions on Power Delivery.