RLCYC 75 : a 2 kW electrically calibrated laser calorimeter designed for Laser MegaJoule diagnostics calibration

RLCYC 75 is a new electrically calibrated laser calorimeter specially manufactured by Laser Metrology to calibrate energy diagnostics within the Laser MegaJoule (LMJ) facility. It consists of an optical cavity cooled by a hydraulic system. The system is designed to provide 1??m wavelength power laser measurements with uncertainty less than 1% at 2?kW and traceability to the International System of Units (SI). In this paper, the accuracy of RLCYC 75 measurements is studied. More precisely, three points are detailed: instrumentation uncertainty estimation, equivalence between optical and electrical supply and light absorption. To this end, electrical calibration campaigns and power laser measurement campaigns are conducted. Moreover, thermal and optical models are developed. Results show that RLCYC 75 design and instrumentation are efficient enough to reach the goal of relative uncertainty of about 1% at 2?kW. RLCYC 75 will become the 2?kW laser power primary standard for LMJ applications.

[1]  Thermal characterization of a cryogenic radiometer and comparison with a laser calorimeter , 1998 .

[2]  Philippe Bouchut,et al.  Design, optical characterization, and operation of large transmission gratings for the laser integration line and laser megajoule facilities. , 2005, Applied optics.

[3]  E. Ryabov,et al.  Intramolecular vibrational redistribution: from high-resolution spectra to real-time dynamics , 2012 .

[4]  C. Cromer,et al.  National Institute of Standards and Technology high-accuracy cryogenic radiometer. , 1996, Applied optics.

[5]  Denis Penninckx,et al.  FM-to-AM conversion in high-power lasers , 2008 .

[6]  J. Lehman,et al.  Review of ultraviolet and high power laser measurement standards at NIST | NIST , 2006 .

[7]  Zhuomin M. Zhang,et al.  Thermal analysis of the volume absorber in pulsed excimer laser calorimeters , 2000 .

[8]  J. Lehman,et al.  High power laser calibrations at NIST , 2008 .

[9]  Nigel P. Fox,et al.  A Cryogenic Radiometer for Absolute Radiometric Measurements , 1985 .

[10]  D. Franzen,et al.  Absolute reference calorimeter for measuring high power laser pulses. , 1976, Applied optics.

[11]  Marcel Worring,et al.  NIST Special Publication , 2005 .

[12]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[13]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[14]  Joshua A. Hadler,et al.  NIST measurement services :: cw laser power and energy calibrations at NIST , 2007 .

[15]  Thomas Scott,et al.  Nonlinearity Measurements of High-Power Laser Detectors at NIST , 2004, Journal of research of the National Institute of Standards and Technology.

[16]  O. S. Heavens,et al.  New Developments and Applications in Optical Radiometry , 1990 .

[17]  P. Foukal,et al.  Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer. , 1992, Applied optics.

[18]  P. Thacher Calorimeters for pulsed lasers: calibration. , 1976, Applied optics.