Patient-specific instrumentation improves tibial component rotation in TKA

PurposeTo compare the femoral and tibial components rotational alignment in total knee arthroplasty (TKA) performed either with conventional or with patient-specific instrumentation.MethodsForty-five patients underwent primary TKA and were prospectively randomized into two groups: 22 patients into the conventional instrumentation group (group A) and 23 patients into the Signature™ patient-specific instrumentation group (group B). All patients underwent computed tomography of the operated knee in the first week after surgery to measure the components rotation.ResultsThe femoral component rotation was 0.0° (−0.25, 1.0) in group A, and 0.0° (0.0, 1.0) in group B. The tibial component rotation was −16.0° (−18.5, 11.8) in group A, and −16.0° (−19.0, −14.0) in group B. There were no significant differences between the two groups in tibial and femoral components rotation. The difference between the tibial component rotation and the neutral tibial rotation was similar in both groups [2.0° (−0.5, 6.3) in group A and 2.0° (−1.0, 4.0) in group B], but the dispersion around the median was different between the two groups. The amplitude of the difference between tibial rotation and neutral position was 27° (−13, 14) in group A and 9° (−3, 6) in group B.ConclusionsThere is a smaller chance of internal malrotation of the tibial component with the Signature™ patient-specific instrumentation system, with less dispersion and amplitude of the tibial component rotation around the neutral position.Level of evidenceII.

[1]  M. Clayton,et al.  Patellar complications after total condylar arthroplasty. , 1982, Clinical orthopaedics and related research.

[2]  J. Rand,et al.  Posterior cruciate condylar total knee arthroplasty , 1988 .

[3]  D. Dennis,et al.  Posterior cruciate condylar total knee arthroplasty. Average 11-year follow-up evaluation. , 1992, Clinical orthopaedics and related research.

[4]  J. J. Jacobs,et al.  Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty , 1998, Clinical orthopaedics and related research.

[5]  F. Kummer,et al.  The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation. , 2000, The Journal of arthroplasty.

[6]  R Nagamine,et al.  Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. , 2001, The American journal of knee surgery.

[7]  R. Barrack,et al.  Component Rotation and Anterior Knee Pain After Total Knee Arthroplasty , 2001, Clinical orthopaedics and related research.

[8]  Peter Loan,et al.  Computer-Assisted Navigation in Total Knee Replacement: Results of an Initial Experience in Thirty-five Patients , 2002, The Journal of bone and joint surgery. American volume.

[9]  T. Wyss,et al.  [Significance of axial rotation alignment of components of knee prostheses]. , 2003, Der Orthopade.

[10]  S. Hofmann,et al.  Die Bedeutung der axialen Rotationsausrichtung der Knieprothesenkomponenten , 2003, Der Orthopäde.

[11]  T. Albrecht,et al.  Rotationsfehlstellungen der Komponenten als Ursache chronischer Schmerzen und vorzeitigem Prothesenversagen bei Knieendoprothesen , 2003, Der Orthopäde.

[12]  S. Hofmann,et al.  [Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty]. , 2003, Der Orthopade.

[13]  D. Brotman,et al.  Duration of anesthesia and venous thromboembolism after hip and knee arthroplasty. , 2005, Mayo Clinic proceedings.

[14]  J. Stiehl,et al.  Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty , 2006, International Orthopaedics.

[15]  A. Mullaji,et al.  Blood loss in total knee arthroplasty: an analysis of risk factors , 2007, International Orthopaedics.

[16]  O. Harrysson,et al.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study , 2007, BMC musculoskeletal disorders.

[17]  B. Beynnon,et al.  Early Revision for Component Malrotation in Total Knee Arthroplasty , 2007, Clinical orthopaedics and related research.

[18]  Oliver Kessler,et al.  The clinical consequences of flexion gap asymmetry in total knee arthroplasty. , 2007, The Journal of arthroplasty.

[19]  B. Seedhom,et al.  Accuracy of MRI vs CT imaging with particular reference to patient specific templates for total knee replacement surgery , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[20]  William J Hozack,et al.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. , 2008, The Journal of arthroplasty.

[21]  Sivashankar Chandrasekaran,et al.  Minimally invasive imageless computer-navigated knee surgery: initial results. , 2008, The Journal of arthroplasty.

[22]  Joanne B. Adams,et al.  Patient-specific approach in total knee arthroplasty. , 2008, Orthopedics.

[23]  Michael A. Mont,et al.  Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment , 2009, International Orthopaedics.

[24]  S. Kurtz,et al.  Effect of procedure duration on total hip arthroplasty and total knee arthroplasty survivorship in the United States Medicare population. , 2008, The Journal of arthroplasty.

[25]  B. Morrey Navigated Total Knee Replacement: A Meta-Analysis , 2008 .

[26]  D. Backstein,et al.  Revision total knee arthroplasty for component malrotation is highly beneficial: a case control study. , 2010, The Journal of arthroplasty.

[27]  D. Rowley,et al.  Internal rotational error of the tibial component is a major cause of pain after total knee replacement. , 2010, The Journal of bone and joint surgery. British volume.

[28]  C. Willis-Owen,et al.  Factors affecting the incidence of infection in hip and knee replacement: an analysis of 5277 cases. , 2010, The Journal of bone and joint surgery. British volume.

[29]  Lawrence Joseph,et al.  Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies , 2011, International Orthopaedics.

[30]  S. Hofmann,et al.  Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty , 2012, Knee Surgery, Sports Traumatology, Arthroscopy.

[31]  Simon J. Wall,et al.  Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. , 2011, The Journal of bone and joint surgery. American volume.

[32]  Andrew A. Amis,et al.  The effect of femoral component rotation on the kinematics of the tibiofemoral and patellofemoral joints after total knee arthroplasty , 2011, Knee Surgery, Sports Traumatology, Arthroscopy.

[33]  Daniel Kendoff,et al.  Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome , 2011, Current reviews in musculoskeletal medicine.

[34]  A. Lombardi,et al.  Improved Accuracy of Alignment With Patient-specific Positioning Guides Compared With Manual Instrumentation in TKA , 2012, Clinical orthopaedics and related research.

[35]  Carsten O Tibesku,et al.  Improved femoral component rotation in TKA using patient-specific instrumentation. , 2014, The Knee.