Test and calibration processes for microcalorimeters, with special reference to heat conduction instruments used with aqueous systems.

Calorimeters are normally calibrated by use of electrical heaters, but the calibration values derived may not always be representative for the chemical or biological process investigated. It is therefore important to have available chemical test processes by which the electrical calibration values can be controlled. In some cases, electrical calibration should be replaced by chemical calibrations. With particular reference to needs in work with thermophile heat conduction microcalorimeters, a number of test and calibration processes are presented. Some calibration problems for various types of reaction vessel are discussed.

[1]  I. Wadsö,et al.  Design and testing of a new microcalorimetric vessel for use with living cellular systems and in titration experiments. , 1984, Journal of biochemical and biophysical methods.

[2]  Mark A. Peterson,et al.  The solubility and isotopic fractionation of gases in dilute aqueous solution. I. Oxygen , 1979 .

[3]  M. Pedley,et al.  Solute interactions in dilute aqueous solutions. Part 1.—Microcalorimetric study of the hydrophobic interaction , 1976 .

[4]  I. Wadsö,et al.  Calorimetric measurements on slightly soluble gases in water Enthalpies of solution of helium, neon, argon, krypton, xenon, methane, ethane, propane, n-butane, and oxygen at 288.15, 298.15, and 308.15 K , 1984 .

[5]  I. Wadsö,et al.  Calorimetry as an analytical tool in biochemistry and biology. , 2006, Methods of biochemical analysis.

[6]  I. Wadsö,et al.  Microcalorimetric titration of β-cyclodextrine with adamantane-1-carboxylate , 1986 .

[7]  R. E. Terry,et al.  Calorimetric titration study of the interaction of several uni- and bivalent cations with 15-crown-5, 18-crown-6, and two isomers of dicyclohexo-18-crown-6 in aqueous solution at 25.degree.C and .mu. = 0.1 , 1976 .

[8]  Ingemar Wadsö,et al.  Thermodynamic properties of some mono-, di-, and tri-esters. Enthalpies of solution in water at 288.15 to 318.15 K and enthalpies of vaporization and heat capacities at 298.15 K , 1986 .

[9]  I. Wadsö,et al.  A flow-microcalorimetric vessel for solution of slightly soluble solids , 1986 .

[10]  S. Gronowitz,et al.  Design and Testing of a Micro Reaction Calorimeter. , 1968 .

[11]  Ingemar Wadsö,et al.  A Flow Micro Reaction Calorimeter. , 1968 .

[12]  D. D. Wagman,et al.  The NBS tables of chemical thermodynamic properties : selected values for inorganic and C1 and C2 organic substances in SI units , 1982 .

[13]  I. Wadsö,et al.  A microcalorimetric system for photochemical processes in solution , 1990 .

[14]  I. Wadsö,et al.  A new flow-microcalorimetric vessel for dissolution of small quantities of easily or slightly soluble liquids , 1989 .

[15]  I. Wadsö,et al.  Simultaneous determination of delta G, delta H and delta S by an automatic microcalorimetric titration technique. Application to protein ligand binding. , 1982, Journal of biochemical and biophysical methods.

[16]  I. Wadsö,et al.  A test and calibration process for microcalorimeters used as thermal power meters. , 1982, Journal of biochemical and biophysical methods.

[17]  F. T. Gucker,et al.  A New Micro-Calorimeter: the Heats of Dilution of Aqueous Solutions of Sucrose at 20 and 30° and their Heat Capacities at 25° , 1939 .

[18]  L. Hepler,et al.  Hydration Effects and Acid-Base Equilibria , 1973 .

[19]  T. Benzinger,et al.  MICROCALORIMETRY, NEW METHODS AND OBJECTIVES , 1963 .

[20]  I. Wadsö,et al.  Enthalpies and heat capacities for n-alkan-1-ols in H2O and D2O☆ , 1986 .

[21]  M. V. Kilday The Enthalpy of Solution of SRM 1655 (KCl) in H2O. , 1980, Journal of research of the National Bureau of Standards.

[22]  F. T. Gucker,et al.  The Heats of Dilution, Heat Capacities, and Activities of Urea in Aqueous Solutions from the Freezing Points to 40°1,2 , 1940 .

[23]  I. Wadsö,et al.  A new microcalorimetric vessel for dissolution of slightly soluble gases enthalpies of solution in water of carbon tetrafluoride and sulphur hexafluoride at 288.15, 298.15, and 308.15 k , 1989 .