Quantification of myocardial perfusion in human subjects using 82Rb and wavelet-based noise reduction.

UNLABELLED Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol. METHODS Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic PET scans on 11 healthy volunteers at rest and after hyperemic stress with dipyridamole. Midventricular planes were divided into eight regions of interest, and a wavelet transform protocol was applied to images and time-activity curves. Flow estimates without and with the wavelet approach were compared with those obtained using H2(15)O. RESULTS Over a wide flow range (0.45-2.75 mL/g/min), flow achieved with the wavelet approach correlated extremely closely with values obtained with H2(15)O (y = 1.03 x -0.12; n = 23 studies, r = 0.94, P < 0.001). If the wavelet noise-reduction technique was not used, the correlation was less strong (y = 1.11 x + 0.24; n = 23 studies, r = 0.79, P < 0.001). In addition, the wavelet approach reduced the regional variation from 75% to 12% and from 62% to 11% (P < 0.001 for each comparison) for resting and stress studies, respectively. CONCLUSION The use of a wavelet protocol allows near-optimal noise reduction, markedly enhances the physiologic flow signal within the PET images, and enables accurate measurement of myocardial perfusion with 82Rb in human subjects over a wide range of flows.

[1]  M J Welch,et al.  Regional myocardial perfusion assessed with generator-produced copper-62-PTSM and PET. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  J Czernin,et al.  Noninvasive quantification of regional myocardial blood flow: assessment of myocardial perfusion reserve and collateral circulation. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  H A O'Brien,et al.  Myocardial perfusion with rubidium-82. I. Measurement of extraction fraction and flow with external detectors. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  N. Mullani,et al.  Myocardial perfusion with rubidium-82. II. Effects of metabolic and pharmacologic interventions. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  S. Bergmann,et al.  Noninvasive delineation of the effects of moderate aging on myocardial perfusion. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  H. Schelbert Positron emission tomography and the changing paradigm in coronary artery disease , 2000, Zeitschrift für Kardiologie.

[7]  B E Sobel,et al.  Positron emission tomography of the heart. , 1992, Progress in cardiovascular diseases.

[8]  M. Walsh,et al.  Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. , 1989, Journal of the American College of Cardiology.

[9]  N. Mullani,et al.  First-pass measurements of regional blood flow with external detectors. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  I. Johnstone,et al.  Adapting to Unknown Smoothness via Wavelet Shrinkage , 1995 .

[11]  David L. Donoho,et al.  De-noising by soft-thresholding , 1995, IEEE Trans. Inf. Theory.

[12]  Ronald H. Huesman,et al.  A methodology for specifying PET VOIs using multimodality techniques , 1997, IEEE Transactions on Medical Imaging.

[13]  A F Laine,et al.  Use of wavelet transforms in analysis of time-activity data from cardiac PET. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  P. Herrero,et al.  Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography. , 1992, Circulation research.

[15]  P. Herrero,et al.  Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model. , 1990, Circulation.

[16]  N. Mullani,et al.  Positron imaging of myocardial infarction with rubidium-82. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  M E Phelps,et al.  Rabbit myocardial 82Rb kinetics and a compartmental model for blood flow estimation. , 1989, The American journal of physiology.

[18]  M. Phelps,et al.  Issues in the quantitation of reoriented cardiac PET images. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  Andrew F. Laine,et al.  A Discrete Dyadic Wavelet Transform for Multidimensional Feature Analysis , 1997 .

[20]  M J Welch,et al.  Quantification of regional myocardial blood flow in vivo with H2150* , 2005 .

[21]  H. Schelbert Consideration of Measurements of Myocardial Blood Flow with Positron‐Emission Tomography , 1993, Investigative radiology.

[22]  N. Mullani,et al.  A retrospective study of the diagnostic accuracy of a community hospital-based PET center for the detection of coronary artery disease using rubidium-82. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[23]  M. Phelps,et al.  A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  Andrew F. Laine,et al.  Improving PET-based physiological quantification through methods of wavelet denoising , 2001, IEEE Transactions on Biomedical Engineering.

[25]  Metin Akay,et al.  A Discrete Dyadic Wavelet Transform for Multidimensional Feature Analysis , 1998 .

[26]  I. Johnstone,et al.  Ideal spatial adaptation by wavelet shrinkage , 1994 .