Energy dispersive photon counting detectors for breast imaging

We report on our efforts toward the development of silicon (Si) strip detectors for energy-resolved clinical breast imaging. Typically, x-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a- Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting silicon Si strip detectors. Mammography requires high flux from the x-ray generator, therefore, in order to achieve energy resolved single photon counting, a high output count rate (OCR) for the detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions. We present our methods and results from the optimization of prototype detectors based on Si strip structures. We describe the detector optimization and the development of ASIC readout electronics that provide the required spatial resolution, low noise, high count rate capabilities and minimal power consumption.

[1]  Andrew Maidment,et al.  Evaluation of a photon-counting breast tomosynthesis imaging system , 2005, SPIE Medical Imaging.

[2]  K. Ogawa,et al.  Simulation study on a photon counting X-ray CT system , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[3]  Polad M Shikhaliev,et al.  Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study , 2005, Physics in medicine and biology.

[4]  Katsuyuki Taguchi,et al.  An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors. , 2010 .

[5]  Bradley E. Patt,et al.  New gamma-ray detector structures for electron only charge carrier collection utilizing high-Z compound semiconductors , 1996 .

[6]  R. F. Wagner,et al.  SNR and DQE analysis of broad spectrum X-ray imaging , 1985 .

[7]  Valeria Rosso,et al.  Digital system based on a bichromatic x-ray source and a single-photon counting device: a single-exposure dual-energy mammography approach , 2002, SPIE Medical Imaging.

[8]  X. Llopart,et al.  First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[9]  Katsuyuki Taguchi,et al.  Enabling photon counting clinical X-ray CT , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[10]  William C. Barber,et al.  Fast photon counting CdTe detectors for diagnostic clinical CT: dynamic range, stability, and temporal response , 2010, Medical Imaging.

[11]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[12]  Christer Ullberg,et al.  Dose reduction using photon-counting x-ray imaging , 2001 .

[13]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[14]  M. Danielsson,et al.  Evaluation of a photon counting X-ray imaging system , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[15]  E. Heijne,et al.  X-ray imaging using single photon processing with semiconductor pixel detectors , 2003 .

[16]  B. Mikulec,et al.  Dose reductions in dental X-ray imaging using Medipix , 2003 .

[17]  S. Molloi,et al.  Photon counting computed tomography: concept and initial results. , 2005, Medical physics.

[18]  Kanai S. Shah,et al.  Chapter 12 Other Materials: Status and Prospects , 1995 .

[19]  J. A. Grant,et al.  Extracting material parameters from x-ray attenuation: a CT feasibility study using kilovoltage synchrotron x-rays incident upon low atomic number absorbers. , 2003, Physics in medicine and biology.

[20]  S. Kheddache,et al.  Dose Reduction in Pelvimetry Using a Digital Technique , 1998 .

[21]  M Danielsson,et al.  Detective quantum efficiency dependence on x-ray energy weighting in mammography. , 1999, Medical physics.

[22]  Paul C. Johns Photon-counting detectors for digital radiography and x-ray computed tomography , 2002, Other Conferences.