A qualitative and quantitative assessment of the impact of three processing algorithms with halving of study count statistics in myocardial perfusion imaging: filtered backprojection, maximal likelihood expectation maximisation and ordered subset expectation maximisation with resolution recovery
暂无分享,去创建一个
A. Kelion | A. Peters | A M Peters | J. C. Fowler | B. Modi | B N Modi | J L E Brown | G Kumar | R M Driver | A D Kelion | J C Fowler | R. Driver | J. L. E. Brown | G. Kumar
[1] Linda K. Shaw,et al. Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies , 2007, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[2] S. Underwood,et al. Procedure guidelines for radionuclide myocardial perfusion imaging. , 2004, Heart.
[3] J. Case,et al. A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction , 2009, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[4] Douglas G. Altman,et al. Practical statistics for medical research , 1990 .
[5] H. Malcolm Hudson,et al. Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.
[6] L. Shepp,et al. Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.
[7] Value of the History and Physical in Identifying Patients at Increased Risk for Coronary Artery Disease , 1993 .
[8] J. Ballinger. Short- and long-term responses to molybdenum-99 shortages in nuclear medicine. , 2010, The British journal of radiology.
[9] E. Gordon DePuey,et al. Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: A comparison to “full-time” filtered backprojection , 2008, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[10] E. Depuey,et al. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum , 2009, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.
[11] E. Ficaro,et al. 15.34: Effect of reconstruction parameters and acquisition times on myocardial perfusion distribution in normals , 2008 .
[12] E. Gordon DePuey,et al. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT , 2011, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.