Quality assurance/quality control of foot and mouth disease solid phase competition enzyme-linked immunosorbent assay--Part II. Quality control: comparison of two charting methods to monitor assay performance.

Diagnostic laboratories are increasingly required to meet stringent quality standards, and validated assays are needed to achieve formal accreditation. Validation of test methods is often considered to be finalised when the assay parameters and characteristics have been established. However, like any process, diagnostic assays are subject to random variation resulting in shifts in the mean test values. Continuous monitoring of assays using control charts will alert the interpreter of changes in performance. For this purpose, several charting methods have been developed and implemented. This paper compares the Shewhart and the exponentially weighted moving average (EWMA) control charts with respect to the day to day monitoring of internal quality control samples for the foot and mouth disease solid phase competition enzyme-linked immunosorbent assay. Both chart types are equally sensitive to shifts, but the EWMA method seems to provide the best balance between false rejection and false acceptance.

[1]  P. Wright,et al.  Standardisation and validation of enzyme-linked immunosorbent assay techniques for the detection of antibody in infectious disease diagnosis. , 1993, Revue scientifique et technique.

[2]  J. Westgard,et al.  Combined Shewhart-cusum control chart for improved quality control in clinical chemistry. , 1977, Clinical chemistry.

[3]  P. Büscher,et al.  Charting methods to monitor the operational performance of ELISA method for the detection of antibodies against trypanosomes. , 2001, Veterinary parasitology.

[4]  C. Hamblin,et al.  A new enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against foot-and-mouth disease virus. I. Development and method of ELISA. , 1986, Journal of immunological methods.

[5]  A S Neubauer,et al.  The EWMA control chart: properties and comparison with other quality-control procedures by computer simulation. , 1997, Clinical chemistry.

[6]  D. Mackay,et al.  A solid-phase competition ELISA for measuring antibody to foot-and-mouth disease virus. , 2001, Journal of virological methods.

[7]  E R JENNINGS,et al.  The use of control charts in the clinical laboratory. , 1950, American journal of clinical pathology.

[8]  S D Blacksell,et al.  Use of combined Shewhart-CUSUM control charts in internal quality control of enzyme-linked immunosorbent assays for the typing of foot and mouth disease virus antigen. , 1994, Revue scientifique et technique.

[9]  E. Beck,et al.  Improvement of a serodiagnostic strategy for foot-and-mouth disease virus surveillance in cattle under systematic vaccination: a combined system of an indirect ELISA-3ABC with an enzyme-linked immunoelectrotransfer blot assay , 2000, Archives of Virology.

[10]  K. De Clercq,et al.  Quality assurance/quality control of foot and mouth disease solid phase competition enzyme-linked immunosorbent assay--Part I. Quality assurance: development of secondary and working standards. , 2005, Revue scientifique et technique.

[11]  M. Callens,et al.  Differentiation of the seven serotypes of foot-and-mouth disease virus by reverse transcriptase polymerase chain reaction. , 1997, Journal of virological methods.

[12]  M. D. Diego,et al.  THE non-structural polyprotein 3ABC of foot-and-mouth disease virus as a diagnostic antigen in ELISA to differentiate infected from vaccinated cattle , 1997, Archives of Virology.

[13]  A. R. Crathorne,et al.  Economic Control of Quality of Manufactured Product. , 1933 .

[14]  N. Ferris,et al.  Comparison of reverse transcription polymerase chain reaction, enzyme linked immunosorbent assay and virus isolation for the routine diagnosis of foot-and-mouth disease. , 1998, Journal of virological methods.

[15]  S. Alexandersen,et al.  Validation of a foot-and-mouth disease antibody screening solid-phase competition ELISA (SPCE). , 2004, Journal of virological methods.

[16]  P. Wright Enzyme immunoassay: observations on aspects of quality control. , 1987, Veterinary immunology and immunopathology.

[17]  H. Hotelling,et al.  Multivariate Quality Control , 1947 .

[18]  Jacobson Rh Validation of serological assays for diagnosis of infectious diseases. , 1998 .

[19]  M. Dawson,et al.  Routine application of enzyme-linked immunosorbent assay in comparison with complement fixation for the diagnosis of foot-and-mouth and swine vesicular diseases. , 1988, Veterinary microbiology.

[20]  R. H. Jacobson Validation of serological assays for diagnosis of infectious diseases. , 1998, Revue scientifique et technique.

[21]  J. Crowther,et al.  A new enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against foot-and-mouth disease virus. II. Application. , 1986, Journal of immunological methods.

[22]  J A GOOSZEN,et al.  The use of control charts in the clinical laboratory. , 1960, Clinica chimica acta; international journal of clinical chemistry.

[23]  S. A. Cawte,et al.  Long-term quality control of DXA: A comparison of shewhart rules and cusum charts , 2005, Osteoporosis International.

[24]  J O Westgard,et al.  A multi-rule Shewhart chart for quality control in clinical chemistry. , 1981, Clinical chemistry.

[25]  Stephen V. Crowder,et al.  Design of Exponentially Weighted Moving Average Schemes , 1989 .