Definition of System Suitability Test Limits on the Basis of Robustness TestResults

A chromatographic method newly optimized to identify and assay four antihypertensive drugs in tablet dosage forms was complemented by a robustness test. The best system suitability criteria for numerous responses were evaluated on the basis of the robustness test results. Generally speaking, it is difficult to achieve a total satisfactory solution. Situations may also become ambiguous if the system suitability limits for few responses of a robust method are violated. In this context, it becomes crucial to redefine these limits based on the robustness test results. In the present study, the extreme experimental (worst-case) conditions that offer worst result but still acceptable and likely to occur were predicted from the robustness test effects. Eventually, replicated experiments were executed in such worst conditions and the system suitability test (SST) limits were determined.

[1]  M. Mulholland,et al.  Ruggedness testing in analytical chemistry , 1988 .

[2]  C. M. Rolim,et al.  RAPID SIMULTANEOUS DETERMINATION OF ALISKIREN AND HYDROCHLOROTHIAZIDE FROM THEIR PHARMACEUTICAL FORMULATIONS BY MONOLITHIC SILICA HPLC COLUMN EMPLOYING EXPERIMENTAL DESIGNS , 2011 .

[3]  R. Plackett,et al.  THE DESIGN OF OPTIMUM MULTIFACTORIAL EXPERIMENTS , 1946 .

[4]  Limei Zhao,et al.  A liquid chromatography/tandem mass spectrometry method for the simultaneous quantification of valsartan and hydrochlorothiazide in human plasma. , 2007, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[5]  C. Kothari,et al.  Concurrent estimation of amlodipine besylate, hydrochlorothiazide and valsartan by RP-HPLC, HPTLC and UV-spectrophotometry. , 2014, Journal of chromatographic science.

[6]  Y. Vander Heyden,et al.  Comparison of Plackett-Burman and supersaturated designs in robustness testing. , 2007, Analytica chimica acta.

[7]  Lutgarde M. C. Buydens,et al.  RES, AN EXPERT SYSTEM FOR THE SET-UP AND INTERPRETATION OF A RUGGEDNESS TEST IN HPLC METHOD VALIDATION .1. THE RUGGEDNESS TEST IN HPLC METHOD VALIDATION , 1991 .

[8]  Desire L. Massart,et al.  Determination of system suitability limits with a robustness test , 1999 .

[9]  K. Fahrbach,et al.  Effect of amlodipine on systolic blood pressure. , 2003, Clinical therapeutics.

[10]  S. Vignaduzzo,et al.  DEVELOPMENT AND VALIDATION OF AN HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF AMLODIPINE, HYDROCHLOROTHIAZIDE, AND VALSARTAN IN TABLETS OF THEIR NOVEL TRIPLE COMBINATION AND BINARY PHARMACEUTICAL ASSOCIATIONS , 2011 .

[11]  Richard G. Brereton Chemometrics: Experimental design (Analytical chemistry by open learning, paperback edition): E. Morgan, Wiley, Chichester, 1995, vii + 275 pp., ISBN 0-471-95832-8 , 1996 .

[12]  K. Gupta,et al.  UV Spectrophotometric Determination of Hydrochlorothiazide and Olmesartan Medoxomil in Pharmaceutical Formulation , 2010 .

[13]  W. J Youden,et al.  Statistical Manual of the Association of Official Analytical Chemists , 1984 .

[14]  J. Crabbe Robustness of Analytical Methods and Pharmaceutical Technological Products , 1997 .

[15]  Y. Heyden,et al.  Guidance for robustness/ruggedness tests in method validation. , 2001, Journal of pharmaceutical and biomedical analysis.

[16]  Johanna Smeyers-Verbeke,et al.  Handbook of Chemometrics and Qualimetrics: Part A , 1997 .

[17]  J. Hoogmartens,et al.  Robustness testing of a liquid chromatography method for the determination of vorozole and its related compounds in oral tablets. , 1998, Journal of pharmaceutical and biomedical analysis.

[18]  M. Mulholland,et al.  Development and evaluation of an automated procedure for the ruggedness testing of chromatographic conditions in high-performance liquid chromatography , 1987 .

[19]  Paul J. Worsfold,et al.  Chemometrics: Experimental design , 1996 .