Fluorescence diffuse optical tomography using the split Bregman method.

PURPOSE Standard image reconstruction methods for fluorescence Diffuse Optical Tomography (fDOT) generally make use of L2-regularization. A better choice is to replace the L2 by a total variation functional that effectively removes noise while preserving edges. Among the wide range of approaches available, the recently appeared Split Bregman method has been shown to be optimal and efficient. Furthermore, additional constraints can be easily included. We propose the use of the Split Bregman method to solve the image reconstruction problem for fDOT with a nonnegativity constraint that imposes the reconstructed concentration of fluorophore to be positive. METHODS The proposed method is tested with simulated and experimental data, and results are compared with those yielded by an equivalent unconstrained optimization approach based on Gauss-Newton (GN) method, in which the negative part of the solution is projected to zero after each iteration. In addition, the method dependence on the parameters that weigh data fidelity and nonnegativity constraints is analyzed. RESULTS Split Bregman yielded a reduction of the solution error norm and a better full width at tenth maximum for simulated data, and higher signal-to-noise ratio for experimental data. It is also shown that it led to an optimum solution independently of the data fidelity parameter, as long as the number of iterations is properly selected, and that there is a linear relation between the number of iterations and the inverse of the data fidelity parameter. CONCLUSIONS Split Bregman allows the addition of a nonnegativity constraint leading to improve image quality.

[1]  Wotao Yin,et al.  An Iterative Regularization Method for Total Variation-Based Image Restoration , 2005, Multiscale Model. Simul..

[2]  Vasilis Ntziachristos,et al.  Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography on the optical forward problem. , 2009, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  J. Ripoll,et al.  Free-space propagation of diffuse light: theory and experiments. , 2003, Physical review letters.

[4]  Vasilis Ntziachristos,et al.  IMAGING SCATTERING MEDIA FROM A DISTANCE: THEORY AND APPLICATIONS OF NONCONTACT OPTICAL TOMOGRAPHY , 2004 .

[5]  Hongkai Zhao,et al.  Multilevel bioluminescence tomography based on radiative transfer equation part 2: total variation and l1 data fidelity. , 2010, Optics express.

[6]  Britton Chance,et al.  Diffuse optical tomography of highly heterogeneous media , 2001, IEEE Transactions on Medical Imaging.

[7]  Vasilis Ntziachristos,et al.  Hybrid System for Simultaneous Fluorescence and X-Ray Computed Tomography , 2010, IEEE Transactions on Medical Imaging.

[8]  Vasilis Ntziachristos,et al.  Looking and listening to light: the evolution of whole-body photonic imaging , 2005, Nature Biotechnology.

[9]  M. Schweiger,et al.  A finite element approach for modeling photon transport in tissue. , 1993, Medical physics.

[10]  R Cubeddu,et al.  A solid tissue phantom for photon migration studies. , 1997, Physics in medicine and biology.

[11]  M. Schweiger,et al.  Anisotropic diffusion regularization methods for diffuse optical tomography using edge prior information , 2006 .

[12]  Ville Kolehmainen,et al.  Split operator method for fluorescence diffuse optical tomography using anisotropic diffusion regularisation with prior anatomical information , 2011, Biomedical optics express.

[13]  L. Rudin,et al.  Nonlinear total variation based noise removal algorithms , 1992 .

[14]  Jie Tian,et al.  A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. , 2010, Optics express.

[15]  Wotao Yin,et al.  Bregman Iterative Algorithms for (cid:2) 1 -Minimization with Applications to Compressed Sensing ∗ , 2008 .

[16]  R. Weissleder,et al.  Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation. , 2001, Optics letters.

[17]  Tom Goldstein,et al.  The Split Bregman Method for L1-Regularized Problems , 2009, SIAM J. Imaging Sci..

[18]  Jorge Ripoll,et al.  Imaging Changes in Lymphoid Organs In Vivo after Brain Ischemia with Three-Dimensional Fluorescence Molecular Tomography in Transgenic Mice Expressing Green Fluorescent Protein in T Lymphocytes , 2008, Molecular imaging.

[19]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[20]  K D Paulsen,et al.  Enhanced frequency-domain optical image reconstruction in tissues through total-variation minimization. , 1996, Applied optics.

[21]  D. Boas Diffuse photon probes of structural and dynamical properties of turbid media: Theory and biomedical applications , 1996 .

[22]  Vasilis Ntziachristos,et al.  A submillimeter resolution fluorescence molecular imaging system for small animal imaging. , 2003, Medical physics.

[23]  M. Schweiger,et al.  Gauss–Newton method for image reconstruction in diffuse optical tomography , 2005, Physics in medicine and biology.

[24]  Gabriele Steidl,et al.  Deblurring Poissonian images by split Bregman techniques , 2010, J. Vis. Commun. Image Represent..

[25]  Vasilis Ntziachristos,et al.  Optimization of 360° projection fluorescence molecular tomography , 2007, Medical Image Anal..

[26]  J. Culver,et al.  Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice. , 2005, Optics express.

[27]  Stanley Osher,et al.  MR image reconstruction from undersampled data by using the iterative refinement procedure , 2007 .

[28]  C. Bouman,et al.  Fluorescence optical diffusion tomography. , 2003, Applied optics.

[29]  V. Ntziachristos,et al.  Projection access order in algebraic reconstruction technique for diffuse optical tomography. , 2002, Physics in medicine and biology.

[30]  M. Schweiger,et al.  Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans. , 2007, Optics express.

[31]  Vasilis Ntziachristos,et al.  Accuracy of fluorescent tomography in the presence of heterogeneities:study of the normalized born ratio , 2005, IEEE Transactions on Medical Imaging.

[32]  Hongkai Zhao,et al.  Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization. , 2010, Optics express.

[33]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[34]  S. Osher,et al.  Quantitative Photoacoustic Tomography , 2012 .

[35]  Inderjit S. Dhillon,et al.  Clustering with Bregman Divergences , 2005, J. Mach. Learn. Res..

[36]  Gultekin Gulsen,et al.  Fully linear reconstruction method for fluorescence yield and lifetime through inverse complex-source formulation: simulation studies. , 2010, Optics letters.

[37]  C. Clason,et al.  Total variation regularization for nonlinear fluorescence tomography with an augmented Lagrangian splitting approach. , 2010, Applied optics.