The Use of Factorial Design and Simplex Optimization to Improve Analytical Performance of In Situ Film Electrodes

This work presents a systematic approach to determining the significance of the individual factors affecting the analytical performance of in-situ film electrode (FE) for the determination of Zn(II), Cd(II), and Pb(II). Analytical parameters were considered simultaneously, where the lowest limit of quantification, the widest linear concentration range, and the highest sensitivity, accuracy, and precision of the method evidenced a better analytical method. Significance was evaluated by means of a fractional factorial (experimental) design using five factors, i.e., the mass concentrations of Bi(III), Sn(II), and Sb(III), to design the in situ FE, the accumulation potential, and the accumulation time. Next, a simplex optimization procedure was employed to determine the optimum conditions for these factors. Such optimization of the in situ FE showed significant improvement in analytical performance compared to the in situ FEs in the initial experiments and compared to pure in situ FEs (bismuth-film, tin-film, and antimony-film electrodes). Moreover, using the optimized in situ FE electrode, a possible interference effect was checked for different species and the applicability of the electrode was demonstrated for a real tap water sample.

[1]  Huimin Zhao,et al.  Signal amplified photoelectrochemical sensing platform with g-C3N4/inverse opal photonic crystal WO3 heterojunction electrode , 2019, Journal of Electroanalytical Chemistry.

[2]  Pedro Araujo,et al.  Chemometrics in chromatography , 2012 .

[3]  M. Finšgar,et al.  Copper-bismuth-film in situ electrodes for heavy metal detection , 2020 .

[4]  K. Vytras,et al.  Antimony Film Microelectrode for Anodic Stripping Measurement of Cadmium(II), Lead(II) and Copper(II) , 2010 .

[5]  M. Finšgar,et al.  Novel in situ Bi−Sb-Film Electrodes for Trace Heavy Metal Analysis , 2018, Electroanalysis.

[6]  V. Jovanovski,et al.  Insights into the anodic stripping voltammetric behaviour of copper film electrodes for determination of trace mercury , 2019, Microchemical Journal.

[7]  Alyssa A. Kava,et al.  Disposable glassy carbon stencil printed electrodes for trace detection of cadmium and lead. , 2020, Analytica chimica acta.

[8]  M Shehata,et al.  Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode , 2020, Sensors.

[9]  H. Cai,et al.  Chip-Level Integration of Covalent Organic Frameworks for Trace Benzene Sensing. , 2020, ACS sensors.

[10]  Ioannis Raptis,et al.  Lithographically fabricated disposable bismuth-film electrodes for the trace determination of Pb(II) and Cd(II) by anodic stripping voltammetry , 2008 .

[11]  Karel Vytras,et al.  Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode , 2009 .

[12]  Hong Qun Luo,et al.  Simultaneous Determination of Trace Zinc(II) and Cadmium(II) by Differential Pulse Anodic Stripping Voltammetry Using a MWCNTs–NaDBS Modified Stannum Film Electrode , 2009 .

[13]  A. Lewenstam,et al.  Direct Potentiometric Determination of Hydrogen Carbonate in Mineral Waters , 2017 .

[14]  A. Economou,et al.  A study of in situ plated tin-film electrodes for the determination of trace metals by means of square-wave anodic stripping voltammetry , 2011 .

[15]  M. Finšgar,et al.  Copper-film electrodes for Pb(II) trace analysis and a detailed electrochemical impedance spectroscopy study , 2019, Microchemical Journal.

[16]  Joseph Wang,et al.  A Decade with Bismuth‐Based Electrodes in Electroanalysis , 2010 .

[17]  Won-Kyu Han,et al.  An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmium , 2008 .

[18]  Yuehe Lin,et al.  Catalytic adsorptive stripping determination of trace chromium (VI) at the bismuth film electrode. , 2004, Talanta.

[19]  P. Trikalitis,et al.  Disposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II). , 2012, Analytica chimica acta.

[20]  Alexander Kuhn,et al.  Macroporous antimony film electrodes for stripping analysis of trace heavy metals , 2010 .

[21]  An Electrochemical Sensor Based on Graphene-Polypyrrole Nanocomposite for the Specific Detection of Pb (II) , 2017 .

[22]  Karel Vytras,et al.  Antimony film electrode for electrochemical stripping analysis. , 2007, Analytical chemistry.

[23]  M. Esteban,et al.  Antimony- based electrodes for analytical determinations , 2016 .

[24]  M. Finšgar,et al.  A Comparison of Hydrochloric Acid and Acetate Buffer Media for Trace Metal Analysis Using Sb-Film Electrodes: A Detailed Electrochemical Impedance Spectroscopy Study , 2019, Journal of The Electrochemical Society.

[25]  André L. Cazetta,et al.  Inexpensive Bismuth-Film Electrode Supported on Pencil-Lead Graphite for Determination of Pb(II) and Cd(II) Ions by Anodic Stripping Voltammetry , 2018, International journal of analytical chemistry.

[26]  Marcos Almeida Bezerra,et al.  Simplex optimization: A tutorial approach and recent applications in analytical chemistry , 2016 .

[27]  A. Economou,et al.  Novel screen-printed antimony and tin voltammetric sensors for anodic stripping detection of Pb(II) and Cd(II) , 2013 .

[28]  Matjaz Finsgar,et al.  Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination , 2018, Sensors.

[29]  Guo Zhao,et al.  Synthesis of a three-dimensional (BiO)2CO3@single-walled carbon nanotube nanocomposite and its application for ultrasensitive detection of trace Pb(II) and Cd(II) by incorporating Nafion , 2019, Sensors and Actuators B: Chemical.

[30]  R. Schirhagl,et al.  Two-dimensional nanomaterial based sensors for heavy metal ions , 2018, Microchimica Acta.

[31]  V. Jovanovski,et al.  Copper film electrode for anodic stripping voltammetric determination of trace mercury and lead , 2015 .

[32]  P. Ortiz,et al.  Multivariate optimization of square wave voltammetry using bismuth film electrode to determine atrazine , 2014 .

[33]  V. Jovanovski,et al.  Bismuth electrodes in contemporary electroanalysis , 2017 .

[34]  Rashid O. Kadara,et al.  Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samples. , 2008, Analytica chimica acta.

[35]  M. Veber,et al.  Functioning of antimony film electrode in acid media under cyclic and anodic stripping voltammetry conditions. , 2013, Analytica chimica acta.

[36]  M. Chehimi,et al.  Polypyrrole-Wrapped Carbon Nanotube Composite Films Coated on Diazonium-Modified Flexible ITO Sheets for the Electroanalysis of Heavy Metal Ions , 2019, Sensors.

[37]  V. Jovanovski,et al.  Ex Situ Prepared Antimony Film Electrode for Electrochemical Stripping Measurement of Heavy Metal Ions , 2009 .

[38]  P. Unwin,et al.  Factors controlling stripping voltammetry of lead at polycrystalline boron doped diamond electrodes: new insights from high-resolution microscopy. , 2011, Analytical chemistry.

[39]  Feng Ju,et al.  Smartphone-Based Electrochemical Potentiostat Detection System Using PEDOT: PSS/Chitosan/Graphene Modified Screen-Printed Electrodes for Dopamine Detection , 2020, Sensors.

[40]  G. March,et al.  Modified Electrodes Used for Electrochemical Detection of Metal Ions in Environmental Analysis , 2015, Biosensors.

[41]  Lu,et al.  Bismuth-coated carbon electrodes for anodic stripping voltammetry , 2000, Analytical chemistry.

[42]  A. Economou,et al.  Miniature 3D-printed integrated electrochemical cell for trace voltammetric Hg(II) determination , 2020 .

[43]  I. Cacciotti,et al.  Effects of Humidity, Temperature and Bismuth Electrodeposition on Electroanalytical Performances of Nafion‐coated Printed Electrodes for Cd 2+ and Pb 2+ Detection , 2020, Electroanalysis.

[44]  Zongqian Hu,et al.  Biomass derived worm-like nitrogen-doped-carbon framework for trace determination of toxic heavy metal lead (II). , 2020, Analytica chimica acta.

[45]  A. Economou,et al.  A study of bismuth-film electrodes for the detection of trace metals by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and human hair. , 2003, Talanta.

[46]  M. Esteban,et al.  New approaches to antimony film screen-printed electrodes using carbon-based nanomaterials substrates. , 2016, Analytica chimica acta.

[47]  Zhencheng Chen,et al.  A Facile Electrochemical Sensor Labeled by Ferrocenoyl Cysteine Conjugate for the Detection of Nitrite in Pickle Juice , 2019, Sensors.

[48]  M. Finšgar,et al.  Bismuth-tin-film electrodes for Zn(II), Cd(II), and Pb(II) trace analysis , 2019, Microchemical Journal.

[49]  Núria Serrano,et al.  Antimony film screen-printed carbon electrode for stripping analysis of Cd(II), Pb(II), and Cu(II) in natural samples. , 2015, Analytica chimica acta.

[50]  M. C. Blanco-López,et al.  Paper-Based Working Electrodes Coated with Mercury or Bismuth Films for Heavy Metals Determination , 2020, Biosensors.

[51]  Dhanjai,et al.  Voltammetric sensing based on the use of advanced carbonaceous nanomaterials: a review , 2018, Microchimica Acta.

[52]  Yue Wang,et al.  Determination of Trace Lead and Cadmium in Decorative Material Using Disposable Screen-Printed Electrode Electrically Modified with Reduced Graphene Oxide/L-Cysteine/Bi-Film , 2020, Sensors.

[53]  Huimin Zhao,et al.  Three-dimension branched crystalline carbon nitride: A high efficiency photoelectrochemical sensor of trace Cu2+ detection , 2020 .

[54]  M. Esteban,et al.  Voltammetric determination of metal ions beyond mercury electrodes. A review. , 2017, Analytica chimica acta.