Covariance analysis of time delay estimates for strained signals

Estimates of time-varying delays from the ultrasonic echo signals of compressed biological media are the basis of a new type of medical imaging known as elastography. This paper is focused on predicting the covariance between time delays estimated from sequential Gaussian-weighted echo segments that overlap. The accuracy of the analysis was tested and improved by comparisons with measurements involving ultrasonic waveforms simulated from independent band-limited Gaussian signal and noise spectra. Data were generated to explore the dependence of time delay covariance on ultrasonic signal-to-noise ratio, time-bandwidth product W, fractional bandwidth, window separation, and the amount of strain (a is the time rate of change in delay). The relationship between a and other experimental parameters was crucial for understanding how signal decorrelation affects time delay error and, ultimately, elastographic noise. For echo waveforms without strain (a=0), delay variance was found to decrease with W. However, when waveform segments were strained (a/spl ne/0) a minimum was found in the plot of time delay variance versus W, where delay errors from additive noise equaled those from signal decorrelation caused by strain. Delay covariance decreased monotonically with increasing window separation (less overlap) when a=0. When a/spl ne/0, however, the covariance became negative for large separations. Properties of strain image noise were predicted from knowledge of the experimental parameters and time delay errors.

[1]  D. Hertz,et al.  Time delay estimation by generalized cross correlation methods , 1984 .

[2]  A. Quazi An overview on the time delay estimate in active and passive systems for target localization , 1981 .

[3]  M. Bilgen,et al.  Deformation models and correlation analysis in elastography. , 1996, The Journal of the Acoustical Society of America.

[4]  Albert Macovski,et al.  Medical imaging systems , 1983 .

[5]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[6]  E. Weinstein,et al.  Delay and Doppler estimation by time-space partition of the array data , 1983 .

[7]  W. Adams,et al.  Correlator compensation requirements for passive time-delay estimation with moving source or receivers , 1980 .

[8]  Ehud Weinstein,et al.  Composite bound on the attainable mean square error in passive time-delay estimation from ambiguity prone signals , 1982, IEEE Trans. Inf. Theory.

[9]  F. Kallel,et al.  Speckle motion artifact under tissue rotation , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Michael F. Insana,et al.  Signal processing strategies in acoustic elastography , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[11]  T. Hall,et al.  2-D companding for noise reduction in strain imaging , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  J. Ophir,et al.  Methods for estimation of subsample time delays of digitized echo signals. , 1995, Ultrasonic imaging.

[13]  J. Ophir,et al.  Methods for Estimation of Subsample Time Delays of Digitized Echo Signals , 1995 .

[14]  G. Carter,et al.  The generalized correlation method for estimation of time delay , 1976 .

[15]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[16]  Correlation of Signals Having a Linear Delay , 1963 .

[17]  R. F. Wagner,et al.  Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[18]  J. Betz,et al.  Comparison of the deskewed short-time correlator and the maximum likelihood correlator , 1984 .

[19]  G. Clifford Carter,et al.  Estimation of time delay in the presence of source or receiver motion , 1977 .

[20]  John W. Betz Effects of uncompensated relative time companding on a broad-band cross correlator , 1985, IEEE Trans. Acoust. Speech Signal Process..

[21]  Stanislav Emelianov,et al.  Biophysical Bases of Elasticity Imaging , 1995 .

[22]  David Hertz,et al.  Time delay estimation by combining efficient algorithms and generalized cross-correlation methods , 1986, IEEE Trans. Acoust. Speech Signal Process..

[23]  G. Carter Coherence and time delay estimation , 1987, Proceedings of the IEEE.

[24]  G. Clifford Carter Coherence and time delay estimation : an applied tutorial for research, development, test, and evaluation engineers , 1993 .

[25]  V. Newhouse,et al.  Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis , 1987, IEEE Transactions on Biomedical Engineering.