Experimental investigation of an electrodialysis regenerator for liquid desiccant

Abstract Liquid desiccant air-conditioning system (LDAS) is a novel air-conditioner with good energy saving potential. Electrodialysis (ED) regeneration is a novel regeneration method for LDAS, which has a higher performance than the conventional thermal regeneration method. In this paper, an experimental setup was developed to study the performance of ED regenerator for liquid desiccant. Based on experimental results, the current utilization of ED regenerator and the mass transfer rate of desiccant solution on unit area of anion-exchange membrane were experimentally obtained. The effects of different flow rates of regenerated and diluted desiccant solution on the current utilization and the mass transfer rate on unit area of anion-exchange membrane are studied. The results show that the largest mass concentration difference between regenerated desiccant solution at the entrance and the exit of the ED regenerator is 0.011%, and the largest mass concentration difference between regenerated desiccant solution at start and end of the experiment is 0.03%. Meanwhile, the largest current utilization of the experimental system of ED regenerator is 55%. Moreover, the current utilization and the mass flow rate of regenerated desiccant solution will increase with the flow rate of desiccant solution.

[1]  H. Strathmann Electrodialysis, a mature technology with a multitude of new applications , 2010 .

[2]  Ahmed M. Hamed,et al.  Theoretical and experimental investigation on the application of solar water heater coupled with air humidifier for regeneration of liquid desiccant , 2011 .

[3]  Xiaohua Liu,et al.  Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator , 2009 .

[4]  Ayman A. Aly,et al.  Solar-powered open absorption cycle modeling with two desiccant solutions , 2011 .

[5]  Lazaros G. Papageorgiou,et al.  Optimal design of an electrodialysis brackish water desalination plant , 2005 .

[6]  Gershon Grossman,et al.  A Liquid Desiccant System for Solar Cooling and Dehumidification , 2004 .

[7]  A. E. Kabeel Augmentation of the performance of solar regenerator of open absorption cooling system , 2005 .

[8]  Xiaosong Zhang,et al.  Double-stage photovoltaic/thermal ED regeneration for liquid desiccant cooling system , 2012 .

[9]  Chaobin Dang,et al.  Experimental analysis of mass transfer in adiabatic structured packing dehumidifier/regenerator with liquid desiccant , 2010 .

[10]  Thosapon Katejanekarn,et al.  An experimental study of a solar-regenerated liquid desiccant ventilation pre-conditioning system , 2009 .

[11]  A. Ertas,et al.  Properties of a new liquid desiccant solution—Lithium chloride and calcium chloride mixture , 1992 .

[12]  Hong-Joo Lee,et al.  Designing of an electrodialysis desalination plant , 2002 .

[13]  S. Jain,et al.  Experimental performance of a liquid desiccant dehumidification system under tropical climates , 2011 .

[14]  G. Grossman Solar-powered systems for cooling, dehumidification and air-conditioning , 2002 .

[15]  Kamel Ghali,et al.  Optimized solar-powered liquid desiccant system to supply building fresh water and cooling needs , 2011 .

[16]  Xiu-Wei Li,et al.  Photovoltaic–electrodialysis regeneration method for liquid desiccant cooling system , 2009 .

[17]  Xiu-Wei Li,et al.  Single-stage and double-stage photovoltaic driven regeneration for liquid desiccant cooling system , 2011 .