Clinical evaluation of scanning laser polarimetry: I Intraoperator reproducibility and design of a blood vessel removal algorithm

AIMS To evaluate the reproducibility of the retardation values (change in polarisation) obtained with the scanning laser polarimeter in a series of normal subjects and glaucoma patients. To improve the analysis of the raw data by devising and evaluating a blood vessel removal algorithm. METHODS Scanning laser polarimetry was performed on 10 normal subjects and 10 glaucoma patients. A series of six images was obtained from each eye. The normal subjects were re-imaged 3 months after their initial assessment. The retardation values obtained from each eye were analysed using the authors’ own methods, including the use of an algorithm to remove blood vessels from the polar profiles. The reproducibility of these measurements and the performance of the blood vessel removal algorithm were assessed. RESULTS The “individual point” coefficient of variation was approximately 12.5% for normal subjects and 17.0% for glaucoma patients. The “integral” coefficient of variation for these groups was approximately 5.5% and 9.5% respectively. The reproducibility of the measurements did not improve with an increased number of measurements. There was no difference in the reproducibility of the measurements in normal subjects over time. The blood vessel removal algorithm improved the reproducibility of the measurements when the shape of the profile was assessed. CONCLUSION The intraoperator reproducibility of retardation values obtained with the scanning laser polarimeter is satisfactory for its use as a clinical tool. The use of a blood vessel removal algorithm improves the reproducibility of the measurements and also assists the clinician in the interpretation of the polar profiles. Furthermore, it allows the construction of normal database polar profiles, thereby enabling the identification, location and quantification of retinal nerve fibre layer damage in an “at risk” individual’s polar profile.

[1]  A. W. Dreher,et al.  Retinal laser ellipsometry : a new method for measuring the retinal nerve fiber layer thickness distribution ? , 1992 .

[2]  R N Weinreb,et al.  Effect of repetitive imaging on topographic measurements of the optic nerve head. , 1993, Archives of ophthalmology.

[3]  H A Quigley,et al.  Quantitative studies of retinal nerve fiber layer defects. , 1982, Archives of ophthalmology.

[4]  L. Zangwill,et al.  Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma. , 1995, American journal of ophthalmology.

[5]  W. Green,et al.  Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy. , 1982, Archives of ophthalmology.

[6]  R. Weinreb,et al.  Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal laser ellipsometer. , 1992, Applied optics.

[7]  G. Tomita,et al.  Evaluation of the Effect of Aging on the Retinal Nerve Fiber Layer Thickness Using Scanning Laser Polarimetry , 1995, Journal of glaucoma.

[8]  L. Zangwill,et al.  Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. , 1995, American journal of ophthalmology.

[9]  R. Varma,et al.  The Optic Nerve in Glaucoma , 1993 .

[10]  P. Airaksinen,et al.  Retinal nerve fiber layer photography in glaucoma. , 1985, Ophthalmology.

[11]  A. Sommer,et al.  The nerve fiber layer in the diagnosis of glaucoma. , 1977, Archives of ophthalmology.

[12]  R. Weinreb,et al.  Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. , 1990, Archives of ophthalmology.

[13]  A. Sommer,et al.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. , 1991, Archives of ophthalmology.

[14]  Andreas W. Dreher,et al.  Scanning laser polarimetry of the retinal nerve fiber layer , 1992, Optics & Photonics.

[15]  T. J. van den Berg,et al.  Retinal nerve fiber layer assessment by scanning laser polarimetry and standardized photography. , 1996, American journal of ophthalmology.