Experimental investigation of high frequency and transient performance of earth rod systems

The high-frequency performance of vertical earth rods is important for designing earthing systems and lightning protection systems. In this work, experimental investigations on the high-frequency and impulse response of vertical earth rods with horizontal electrode enhancements are described. The rod electrode systems are installed at the Cardiff University outdoor earthing test facility and variable frequency tests were carried over the range 50 Hz to 10 MHz. In addition, a low voltage impulse generator was used to inject impulse current of variable magnitude and shape into the electrode under test. The application of `4-point cross' and `8-point star' enhancements to single rods electrodes have not only demonstrated the expected reduction of low frequency earth resistance but have also helped with a reduction in impedance at higher frequencies. Such enhancements may produce a greater overall benefit compared with extending the length of the rod only. Computer simulations of the experimental setups agree quite well with test results over a low frequency range but more significant differences are seen at higher frequencies.

[1]  A. F. Otero,et al.  Frequency-dependent grounding system calculation by means of a conventional nodal analysis technique , 1999 .

[2]  William K. Dick,et al.  Impulse and Alternating Current Tests on Grounding Electrodes in Soil Environment , 1978, IEEE Transactions on Power Apparatus and Systems.

[3]  S. Visacro,et al.  How the frequency dependence of soil parameters affects the lightning response of grounding electrodes , 2012, 2012 International Conference on Lightning Protection (ICLP).

[4]  Ki-Jun Park,et al.  Direct measurement of frequency domain impedance characteristics of grounding system , 2002, Proceedings. International Conference on Power System Technology.

[5]  S. Bourg,et al.  Deep earth electrodes in highly resistive ground: frequency behaviour , 1995, Proceedings of International Symposium on Electromagnetic Compatibility.

[6]  Abderrahmane Haddad,et al.  Frequency response of earthing systems , 2003 .

[7]  M. Popov,et al.  On high-frequency circuit equivalents of a vertical ground rod , 2005, IEEE Transactions on Power Delivery.

[8]  T. Takashima,et al.  High Frequency Characteristics of Impedances to Ground And Field Distributions of Ground Electrodes , 1981, IEEE Transactions on Power Apparatus and Systems.

[9]  A. P. Meliopoulos,et al.  Frequency Dependent Characteristics of Grounding Systems , 1987, IEEE Transactions on Power Delivery.

[10]  Keyhan Sheshyekani,et al.  The Effect of Frequency Dependence of Soil Electrical Parameters on the Lightning Performance of Grounding Systems , 2013, IEEE Transactions on Electromagnetic Compatibility.

[11]  D. Mukhedkar,et al.  Experimental Study of Transient Ground Impedances , 1981, IEEE Transactions on Power Apparatus and Systems.