Blood flow measurements with radionuclide-labeled particles.

When appropriately and correctly applied, the microsphere technique is relatively simple and extremely accurate. Distribution patterns, both of total systemic arterial blood flow or venous return as well as within specific organs, can be measured. Several techniques have been applied to quantitate flow using microspheres; the reference sample method is extremely simple and by far the most accurate of all. Collection of venous effluent is perhaps more accurate but requires extensive surgery and is almost certainly the least physiologic. Other methods used for quantitation, such as bolus injections of indocyanine green dye or in fusions of diffusable indicators, are considerably less accurate and therefore significantly reduce the reliability of the microsphere technique. Selection of the appropriate size microspheres allows for definition of arteriovenous anastomoses as well as the measurement of organ blood flows and distribution of blood flow within those organs. In most instances, smaller microspheres (15mu diameter or 8-10mu diameter) have significant advantages over larger ones. They are distributed more like red cells, obstruct less of the vascular bed, are less variable in size, and can be given in significantly greater numbers. This latter point is important, since the statistical criteria need to be satisfied and the use of small spheres allows for the more reliable measurement of blood flow to small organs or to small regions of organs.

[1]  H. Wagner,et al.  REGIONAL PULMONARY BLOOD FLOW IN MAN BY RADIOISOTOPE SCANNING. , 1964, JAMA.

[2]  H. Wagner,et al.  Measure- ment of distribution of cardiac output. , 1968, Journal of applied physiology.

[3]  L. Sapirstein,et al.  Regional blood flow by fractional distribution of indicators. , 1958, The American journal of physiology.

[4]  C. R. Smith,et al.  Fractional Distribution of Right Ventricular Output in the Lungs of Dogs , 1962, Circulation research.

[5]  A. G. Pohlman The course of the blood through the heart of the fetal mammal, with a note on the reptilian and amphibian circulations , 1909 .

[6]  M. Heymann,et al.  Cardiovascular responses to hypoxemia and acidemia in fetal lambs. , 1974, American journal of obstetrics and gynecology.

[7]  N. Hollenberg,et al.  Cardiac output distribution in the rat: comparison of rubidium and microsphere methods. , 1971, The American journal of physiology.

[8]  R. Blantz,et al.  Measurement of intrarenal blood flow. I. Analysis of microsphere method. , 1971, The American journal of physiology.

[9]  J. Flasher,et al.  Size of the largest arterio-venous vessels in various organs. , 1953, The American journal of physiology.

[10]  P. Daniel,et al.  Arteriovenous anastomoses in the external ear. , 1956, Quarterly journal of experimental physiology and cognate medical sciences.

[11]  I. Járai The redistribution of cardiac output on cold exposure in new‐born rabbits , 1969, The Journal of physiology.

[12]  H. Wagner,et al.  Preparation of metabolizable radioactive human serum albumin microspheres for studies of the circulation. , 1970, The International journal of applied radiation and isotopes.

[13]  M. Heymann,et al.  Circulatory Changes during Growth in the Fetal Lamb , 1970, Circulation research.

[14]  B. Pasternack,et al.  Some experimental sampling results for regression analysis applied to gamma ray spectrometer data, II. , 1968, Biometrics.

[15]  L. Dong,et al.  Nonuniform distribution of microspheres in blood flowing through a medium-size artery. , 1970, Canadian journal of physiology and pharmacology.

[16]  H. Wagner,et al.  Measurement of the distribution of cardiac output in unanesthetized rats. , 1971, Journal of applied physiology.

[17]  J I Hoffman,et al.  Some sources of error in measuring regional blood flow with radioactive microspheres. , 1971, Journal of applied physiology.

[18]  E. Ornitz,et al.  Arterio-venous anastomoses in liver, spleen, and lungs. , 1947, The American journal of physiology.

[19]  L. Maclean,et al.  Distribution of Blood Flow to the Canine Heart.∗ , 1961, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[20]  H. Wagner,et al.  Radioactive albumin microspheres for studies of the pulmonary circulation. , 1969, Radiology.

[21]  W. Droegemueller,et al.  Measurement of Umbilical Arterial Blood Flow to the Sheep Placenta and Fetus in Utero: DISTRIBUTION TO COTYLEDONS AND THE INTERCOTYLEDONARY CHORION , 1968 .

[22]  H. Wagner,et al.  Studies of the Circulation with Radioactive Microspheres , 1969, Investigative radiology.

[23]  R P Forsyth,et al.  Validity studies of the radioactive microsphere method for the study of the distribution of cardiac output, orn blood flow, and resistance in the conscious rhesus monkey. , 1969, Cardiovascular research.

[24]  S. Duncan The partition of uterine blood flow in the pregnant rabbit , 1969, The Journal of physiology.

[25]  M. Marcus,et al.  Temporal Heterogeneity of Myocardial Blood Flow in Anesthetized Dogs , 1975, Circulation.

[26]  K. Melmon,et al.  Normal distribution of cardiac output in the unanesthetized, restrined rhesus monkey. , 1968, Journal of applied physiology.

[27]  J. Neutze,et al.  Rheology of Microspheres injected into Circulation of Rabbits , 1967, Nature.

[28]  Y. Abe Pressure‐Dependent Heterogeneity of Renal Cortical Blood Flow in Dogs , 1970, Circulation research.

[29]  D. Agostino,et al.  Some unusual aspects of microsphere migration at the microcirculatory level. , 1970, Archives of surgery.

[30]  A M Rudolph,et al.  The Circulation of the Fetus in Utero: Methods For Studying Distribution of Blood Flow, Cardiac Output And Organ Blood Flow , 1967, Circulation research.

[31]  R. Blantz,et al.  Geometric error in tissue gamma-counting: methods for minimization. , 1972, Journal of applied physiology.

[32]  H. Wagner,et al.  A METHOD FOR THE STUDY OF THE PERIPHERAL CIRCULATION IN MAN. , 1965, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  M. Heymann,et al.  Measurement of flow in perfused organs, using microsphere techniques. , 1972, Acta endocrinologica. Supplementum.

[34]  Studies on the coronary circulation , 1947 .

[35]  M. Heymann,et al.  Distribution of systemic blood flow during cardiopulmonary bypass. , 1973, Journal of applied physiology.

[36]  M. Heymann,et al.  Validation of the Antipyrine Method for Measuring Fetal Umbilical Blood Flow , 1967, Circulation research.

[37]  J. Parratt,et al.  THE HAEMODYNAMIC EFFECTS OF QUAZODINE, A CARDIAC STIMULANT, IN EXPERIMENTAL E. COLI ENDOTOXIN SHOCK IN THE CAT , 1974, Clinical and experimental pharmacology & physiology.

[38]  C. Wilson,et al.  Alterations in Intrarenal Blood Flow Distribution: METHODS OF MEASUREMENT AND RELATIONSHIP TO SODIUM BALANCE , 1973, Circulation research.

[39]  N. Hollenberg,et al.  A simple radioactive microsphere method for measuring regional flow and cardiac output. , 1974, Investigative radiology.

[40]  M. Heymann,et al.  Measurement of umbilical blood flow in fetal lambs in utero. , 1975, Journal of applied physiology.

[41]  D. H. Barron,et al.  SIMULTANEOUS MEASUREMENT OF UTERINE AND UMBILICAL BLOOD FLOWS AND OXYGEN UPTAKES , 1967 .

[42]  G. Buckberg,et al.  Total and Regional Myocardial Blood Flow Measurements with 25μ, 15μ, 9μ, and Filtered 1–10μ Diameter Microspheres and Antipyrine in Dogs and Sheep , 1974 .

[43]  M. Heymann,et al.  Lobar distribution of pulmonary arterial blood flow in awake standing dogs. , 1970, The American journal of physiology.

[44]  A. Logan,et al.  Microsphere Measurement of Intrarenal Circulation of the Dog , 1971, Circulation research.

[45]  G. Ring,et al.  Size of microspheres passing through pulmonary circuit in the dog. , 1961, The American journal of physiology.

[46]  J. Delaney,et al.  CANINE GASTRIC BLOOD FLOW AND ITS DISTRIBUTION. , 1964, The American journal of physiology.

[47]  W. Droegemueller,et al.  Distribution of uterine blood flow in the pregnant sheep. , 1968, American journal of obstetrics and gynecology.

[48]  M. de Swiet,et al.  Trapping of radioactive microspheres in the pregnant and non-pregnant rabbit. , 1974, Acta physiologica Scandinavica.

[49]  N. Eckhoff,et al.  Area-of-interest unfolding , 1971 .

[50]  J. Mclaughlin,et al.  The distribution of pulmonary blood flow after subclavian-pulmonary anastomosis. An experimental study. , 1965, The Journal of thoracic and cardiovascular surgery.

[51]  J. Ledingham,et al.  Measurement of cardiac output distribution using microspheres. Some practical and theoretical considerations. , 1974, Cardiovascular research.

[52]  L. Sapirstein Fractionation of the Cardiac Output of Rats with Isotopic Potassium , 1956, Circulation research.

[53]  J. Delaney Arteriovenous anastomotic blood flow in the mesenteric organs. , 1969, The American journal of physiology.

[54]  A M Rudolph,et al.  Use of radioactive microspheres to assess distribution of cardiac output in rabbits. , 1968, The American journal of physiology.

[55]  D. Ullyot,et al.  Measurement of cardiac output with and organ trapping of radioactive microspheres. , 1973, Journal of applied physiology.

[56]  J. F. Perry,et al.  Isotope localization with tagged microspheres. , 1961, Surgery.

[57]  H. Wagner,et al.  Total and regional cerebral blood flow in unanesthetized dogs. , 1970, The American journal of physiology.

[58]  M. Noble,et al.  Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs , 1969, Circulation research.