On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations

The power spectral density in the Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well-considered averaging time. However, this approach requires further mathematical justification and refinement, which has already been done regarding the original ADEV for certain noise types. Here we provide the necessary background to use the modified Allan deviation (modADEV) and other two-sample deviations to determine the uncertainty of weighted frequency averages. The type of two-sample deviation used to determine the uncertainty depends on the method used for determination of the average. We find that the modADEV, which is connected with -weighted averaging, and the two-sample deviation associated with a linear phase regression weighting (parADEV) are, in particular, advantageous for measurements in which white phase noise is dominating. Furthermore, we derive a procedure for how to minimise the uncertainty of a measurement for a typical combination of white phase and frequency noise by adaptive averaging of the data set with different weighting functions. Finally, some aspects of the theoretical considerations for real-world frequency measurement equipment are discussed.

[1]  Zach DeVito,et al.  Opt , 2017 .

[2]  D. W. Allan,et al.  Statistics of atomic frequency standards , 1966 .

[3]  T. J. Witt Practical methods for treating serial correlations in experimental observations , 2009 .

[4]  S. Johansson,et al.  New frequency counting principle improves resolution , 2005, Proceedings of the 20th European Frequency and Time Forum.

[5]  W. Klische,et al.  Extra high precision digital phase recorder , 2004 .

[6]  I. Sesia,et al.  Estimating the Allan variance in the presence of long periods of missing data and outliers , 2008 .

[7]  A. Ludlow,et al.  An Atomic Clock with 10–18 Instability , 2013, Science.

[8]  Enrico Rubiola,et al.  On the measurement of frequency and of its sample variance with high-resolution counters , 2005 .

[9]  E. Rubiola,et al.  Least-square fit, Ω counters, and quadratic variance , 2015, 2015 Joint Conference of the IEEE International Frequency Control Symposium & the European Frequency and Time Forum.

[10]  J. Coupland,et al.  Determination of the transfer function for optical surface topography measuring instruments—a review , 2013 .

[11]  G Grosche,et al.  Optical frequency transfer via a 660 km underground fiber link using a remote Brillouin amplifier. , 2014, Optics express.

[12]  R. Dach,et al.  Comparison between frequency standards in Europe and the USA at the 10−15 uncertainty level , 2006 .

[13]  T. Hänsch,et al.  A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place , 2012, Science.

[14]  D. W. Allan,et al.  Should the classical variance be used as a basic measure in standards metrology? , 1987, IEEE Transactions on Instrumentation and Measurement.

[15]  J.J. McFerran,et al.  Considerations on the measurement of the stability of oscillators with frequency counters , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  P. Lesage,et al.  Characterization of Frequency Stability: Analysis of the Modified Allan Variance and Properties of Its Estimate , 1984, IEEE Transactions on Instrumentation and Measurement.

[17]  Thomas Udem,et al.  Optical frequency transfer over a single-span 1840 km fiber link , 2013, CLEO: 2013.

[18]  D. Yu,et al.  The uncertainty associated with the weighted mean frequency of a phase-stabilized signal with white phase noise , 2010 .

[19]  W. Klische,et al.  Multi-channel synchronous digital phase recorder , 2001, Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218).

[20]  Józef Kalisz,et al.  Review of methods for time interval measurements with picosecond resolution , 2004 .

[21]  Gesine Grosche,et al.  Brillouin amplification supports 1 × 10 − 20 uncertainty in optical frequency transfer over 1400 km of underground fiber , 2015, 1504.01567.