This research study showed the potential of block bundle ad- justment with nadir viewing sensor images, such as Landsat 7 ETM� . The method is based on the 3D analytical geometric model developed for multisensor images at the Canada Centre for Remote Sensing, Natural Resources Canada. Different block sizes and configurations were tested and compared using an image bundle adjustment. The different tests using 15 Landsat 7 ETMimages (five paths and three rows) ac- quired over a study site in the Canadian Rocky Mountains, showed that the same results (around 25-m errors) could be obtained with image blocks as with a single image using a largely reduced number of ground control points (GCPs). How- ever, the combined image measurement and map errors of GCPs were included in the final error budget, and the internal accuracy of the blocks should be better (around one pixel or less). The number of GCPs to be used depended mainly on the cartographic data accuracy: more GCPs than the minimum re- quired reduced the error propagation in the least-squares block bundle adjustment. In addition, tie points with a known elevation value (elevation tie points, ETPs) instead of normal tie points were used to link the adjacent images/strips (north- south and east-west) because the viewing-angle differences of overlapping images were smaller than 1° in north-south over- laps and around 10° in east-west overlaps. Better and more consistent results were also obtained using strips of images in the blocks acquired from the same orbit and date instead of using independent images. Finally, using only GCPs in the outer strips/images and ETPs in each overlap achieved the same results (25-m errors).