Deep Reinforcement Learning-Based Approach for Proportional Resonance Power System Stabilizer to Prevent Ultra-Low-Frequency Oscillations

Recent studies have shown that due to the hammer effect of the governor, hydropower units are easily creating negative damping torque at the common mode frequency (below 0.1 Hz). Therefore, there is a risk of ultra low frequency oscillations (ULFO) in hydropower-dominated systems. ULFO is a small-signal frequency oscillation problem, which is quite different from low frequency oscillations (LFO). A conventional power system stabilizer (CPSS) has less effect on suppressing ULFO. To solve this problem, this paper proposes a high-order polynomial structure to replace the CPSS, and combine it with a proportional resonance controller to form a novel PR-PSS. In order to ensure the robustness of PR-PSS, based on the characteristic analysis results of the PR-PSS, a deep reinforcement learning (DRL) algorithm asynchronous advantage actor-critic (A3C) is introduced to train an agent. After training, the proposed agent can provide optimal parameter settings for PR-PSS under various operating conditions. Simulation results verify the effectiveness of the proposed method.

[1]  Woei-Luen Chen,et al.  One-Dimensional Optimization for Proportional–Resonant Controller Design Against the Change in Source Impedance and Solar Irradiation in PV Systems , 2014, IEEE Transactions on Industrial Electronics.

[2]  Alex Graves,et al.  Asynchronous Methods for Deep Reinforcement Learning , 2016, ICML.

[3]  I. Kamwa,et al.  Fundamental study of common mode small-signal frequency oscillations in power systems , 2019, International Journal of Electrical Power & Energy Systems.

[4]  Haifeng Wang,et al.  A unified model for the analysis of FACTS devices in damping power system oscillations. III. Unified power flow controller , 2000 .

[5]  Boon-Teck Ooi,et al.  Co-Ordinated PSS Tuning of Large Power Systems by Combining Transfer Function-Eigenfunction Analysis (TFEA), Optimization, and Eigenvalue Sensitivity , 2014, IEEE Transactions on Power Systems.

[6]  Haoyong Chen,et al.  Analysis of ultra-low frequency oscillation in yunnan asynchronous sending system , 2017, 2017 IEEE Power & Energy Society General Meeting.

[7]  Peng Shi,et al.  Ultra-low frequency oscillation analysis and robust fixed order control design , 2019, International Journal of Electrical Power & Energy Systems.

[8]  R. Grondin,et al.  IEEE PSS2B versus PSS4B: the limits of performance of modern power system stabilizers , 2005, IEEE Transactions on Power Systems.

[9]  Hugo N. Villegas,et al.  Electromechanical Oscillations in Hydro-Dominant Power Systems: An Application to the Colombian Power System , 2011 .

[10]  Rui Yu,et al.  Optimization Strategy of Hydrogovernors for Eliminating Ultralow-Frequency Oscillations in Hydrodominant Power Systems , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[11]  Zhao Hui,et al.  Optimal Design of Power System Stabilizer Using Particle Swarm Optimization , 2006 .

[12]  Junwei Cao,et al.  Optimal energy management strategies for energy Internet via deep reinforcement learning approach , 2019, Applied Energy.

[13]  M. A. Abido Optimal des'ign of Power System Stabilizers Using Particle Swarm Opt'imization , 2002, IEEE Power Engineering Review.

[14]  Haoyong Chen,et al.  Analysis and Measures of Ultralow-Frequency Oscillations in a Large-Scale Hydropower Transmission System , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[15]  Xialing Xu,et al.  Online emergency control to suppress frequency oscillations based on damping evaluation using dissipation energy flow , 2018, International Journal of Electrical Power & Energy Systems.

[16]  Ferber R. Schleif,et al.  Damping of System Oscillations with a Hydrogenerating Unit , 1967 .

[17]  Kevin Tomsovic,et al.  Design and analysis of an adaptive fuzzy power system stabilizer , 1996 .

[18]  Qun Chen,et al.  Optimization of Governor Parameters to Prevent Frequency Oscillations in Power Systems , 2018, IEEE Transactions on Power Systems.

[19]  Zheng Xu,et al.  Mechanism analysis and suppression method of ultra-low-frequency oscillations caused by hydropower units , 2018, International Journal of Electrical Power & Energy Systems.

[20]  Jinyu Wen,et al.  Effect analysis of generator governor system and its frequency mode on inter-area oscillations in power systems , 2018 .

[21]  Haibo He,et al.  Model-Free Real-Time EV Charging Scheduling Based on Deep Reinforcement Learning , 2019, IEEE Transactions on Smart Grid.

[22]  T. C. Yang Applying H∞ optimisation method to power system stabiliser design Part 2: Multi-machine power systems , 1997 .

[23]  Ramtin Hadidi,et al.  Reinforcement Learning Based Real-Time Wide-Area Stabilizing Control Agents to Enhance Power System Stability , 2013, IEEE Transactions on Smart Grid.

[24]  J. D. McCalley,et al.  Analysis of Very Low Frequency Oscillations in Hydro-Dominant Power Systems Using Multi-Unit Modeling , 2012, IEEE Transactions on Power Systems.

[25]  L. Gerin-Lajoie,et al.  Benchmark Models for the Analysis and Control of Small-Signal Oscillatory Dynamics in Power Systems , 2017, IEEE Transactions on Power Systems.

[26]  Liang Tu,et al.  A Novel Adaptive Wide Area PSS Based on Output-Only Modal Analysis , 2015, IEEE Transactions on Power Systems.

[27]  Innocent Kamwa,et al.  An approach to PSS design for transient stability improvement through supplementary damping of the common low-frequency , 1993 .