The consumption of lighting energy in buildings continues to rise, and many studies are being conducted to address this problem. As part of such initiatives, research is being performed on light shelves, which are natural lighting systems. However, most prior studies focused on variables for operating flat reflectors and light shelves. This study aims to evaluate the performance of curved light shelves to prove their effectiveness and derive optimal specifications for them. The following conclusions were reached. The optimal light shelf angles for a flat light shelf were found to be 30°, 20°, and 20° for the summer, mid-season, and winter, respectively, and accordingly, a movable light shelf system would be suitable for all three seasons. The optimal light shelf angles for a movable curved light shelf with an arc angle of 60° were found to be 30°, 30°, and 10° for the summer, mid-season, and winter, respectively. The optimal light shelf angle and arc angle for a fixed-type curved light shelf were found to be 20° and 60°, respectively. A fixed-type curved light shelf designed according to these optimal specifications can reduce energy consumption by 3.6% in comparison to a movable flat light shelf. Consequently, the curved light shelf is considered an effective system, and additional studies analyzing various other factors should be carried out in the future.

[1]  Heangwoo Lee,et al.  A preliminary study on the performance of an awning system with a built-in light shelf , 2018 .

[2]  Heangwoo Lee Performance evaluation of a light shelf with a solar module based on the solar module attachment area , 2019, Building and Environment.

[3]  Heangwoo Lee,et al.  Study on movable light-shelf system with location-awareness technology for lighting energy saving , 2017 .

[4]  S. Medved,et al.  Evolution of all-glass nearly Zero Energy Buildings with respect to the local climate and free-cooling techniques , 2019, Building and Environment.

[5]  Daniela Isidori,et al.  HVAC Optimization Genetic Algorithm for Industrial Near-Zero-Energy Building Demand Response , 2019, Energies.

[6]  Heangwoo Lee,et al.  Evaluation of a light shelf based on energy consumption for lighting and air conditioning , 2017 .

[7]  Heangwoo Lee,et al.  Development of a wall module employing aircap layers , 2018, Energy and Buildings.

[8]  Yaik Wah Lim,et al.  Dynamic internal light shelf for tropical daylighting in high-rise office buildings , 2016 .

[9]  Heangwoo Lee,et al.  Improvement of light-shelf performance through the use of a diffusion sheet , 2018, Building and Environment.

[10]  Heangwoo Lee,et al.  Development and Performance Evaluation of Light Shelves Using Width-Adjustable Reflectors , 2018 .

[11]  Mohammad Hossein Moazzeni,et al.  Investigating the Influence of Light Shelf Geometry Parameters on Daylight Performance and Visual Comfort, a Case Study of Educational Space in Tehran, Iran , 2016 .

[12]  Heangwoo Lee,et al.  Development of a Dimming Lighting Control System Using General Illumination and Location-Awareness Technology , 2018, Energies.

[13]  Hyang-In Jang,et al.  Energy-saving performance of light shelves under the application of user-awareness technology and light-dimming control , 2019, Sustainable Cities and Society.

[14]  Alfonso Soler,et al.  Indoor daylight climate–influence of light shelf and model reflectance on light shelf performance in Madrid for hours with unit sunshine fraction , 2002 .

[15]  Alfonso Soler,et al.  Light shelf performance in Madrid, Spain , 1997 .

[16]  Benny Raphael,et al.  Performance evaluation of light shelves , 2017 .

[17]  Jae-Bum Lee,et al.  Power Generation Performance of Building-Integrated Photovoltaic Systems in a Zero Energy Building , 2019 .