Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump

To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.

[1]  Ju-Suk Byun,et al.  Frost retardation of an air-source heat pump by the hot gas bypass method , 2008 .

[2]  Woo-Seung Kim,et al.  Effect of surface treatments on the frosting/defrosting behavior of a fin-tube heat exchanger , 2002 .

[3]  Neil Hewitt,et al.  Defrost cycle performance for a circular shape evaporator air source heat pump , 2008 .

[4]  Xian-min Guo,et al.  Dynamic defrosting characteristics of air source heat pump and effects of outdoor air parameters on defrost cycle performance , 2009 .

[5]  Dennis L. O'Neal,et al.  Frosting performance of tube fin heat exchangers with wavy and corrugated fins , 1991 .

[6]  S. W. Wang,et al.  A new method for preventing HP from frosting , 2005 .

[7]  Omar M. Al-Rabghi,et al.  Proposed energy-efficient air-conditioning system using liquid desiccant , 1996 .

[8]  Viung C. Mei,et al.  A Frost-Less Heat Pump , 2002 .

[9]  Pradeep Bansal,et al.  Performance analysis of liquid desiccant dehumidification systems , 2007 .

[10]  Takao Nishimura,et al.  “Heat pumps — status and trends” in Asia and the Pacific , 2002 .

[11]  Dong Huang,et al.  Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump , 2009 .

[12]  Dennis L. O'Neal,et al.  Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor , 1995 .

[13]  Xingqun Zhang,et al.  Effects of fan-starting methods on the reverse-cycle defrost performance of an air-to-water heat pump , 2004 .

[14]  Honghyun Cho,et al.  Performance of a showcase refrigeration system with multi-evaporator during on–off cycling and hot-gas bypass defrost , 2005 .