Control strategy for rotary blood pumps.

The control strategy for ventricular support with a centrifugal blood pump was examined in this study. The control parameter was the pump rpm that determines pump flow. Optimum control of pump rpm that reflects the body's demand is important for long-term, effective, and safe circulatory support. Moreover, continuous, reliable monitoring of ventricular function will help successfully wean the patients from the ventricular assist device (VAD). The control strategy in this study includes determination of the target pump rpm that can provide the flow required by the body, fine-rpm-tuning to minimize deleterious effects such as suction in the ventricle, and assessment of ventricular function for successful weaning from VADs. To determine the target pump rpm, we proposed to use the relation between the native heart rate and cardiac output, and the relation between the pump rpm and centrifugal pump output. For fine-tuning of the pump rpm, the motor current waveform was used. We computed the power spectral density of the motor current waveform and calculated the ratio of the fundamental to the higher order components. When this ratio was larger than approximately 0.2, we assumed there would be a suction effect in the ventricle. As for assessment of ventricular function, we used the amplitude of the motor current waveform. The control system implemented using a DSP functioned properly in the mock circulatory loop as well as in acute animal experiments. The motor current also showed a good correlation with the ventricular pressure in acute animal experiments.

[1]  Hisateru Takano,et al.  Development of a Centrifugal Pump with Improved Antithrombogenicity and Hemolytic Property for Chronic Circulatory Support. , 1996, Artificial organs.

[2]  J T Watson Innovative ventricular assist systems. , 1994, ASAIO journal.

[3]  M Endo,et al.  Current strategy for severe heart failure with mechanical circulatory support. , 1995, Artificial organs.

[4]  S Takatani,et al.  Development of a compact, sealless, tripod supported, magnetically driven centrifugal blood pump. , 2000, Artificial organs.

[5]  T Nakatani,et al.  Long-term circulatory support to promote recovery from profound heart failure. , 1995, ASAIO journal.

[6]  S Takatani,et al.  Control of centrifugal blood pump based on the motor current. , 1997, Artificial organs.

[7]  Teruaki Akamatsu,et al.  OVER NINE MONTHS CONTINUOUS OPERATION OF A CENTRIFUGAL PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER IN A SHEEP , 1997 .

[8]  J F Antaki,et al.  Survival for Up to Six Months in Calves Supported With an Implantable Axial Flow Ventricular Assist Device , 1997, ASAIO journal.

[9]  George Damm,et al.  Development of a Pivot Bearing Supported Sealless Centrifugal Pump for Ventricular Assist. , 1996, Artificial organs.

[10]  D B Olsen,et al.  Test controller design, implementation, and performance for a magnetic suspension continuous flow ventricular assist device. , 1999, Artificial organs.

[11]  T. Tsukiya,et al.  Recent studies of the centrifugal blood pump with a magnetically suspended impeller. , 1995, Artificial organs.

[12]  D B Olsen,et al.  Blood flow in a continuous flow ventricular assist device. , 1999, Artificial organs.

[13]  R Wampler,et al.  A sealless centrifugal blood pump with passive magnetic and hydrodynamic bearings. , 1999, Artificial organs.

[14]  J R Boston,et al.  Controller for an Axial Flow Blood Pump. , 1996, Artificial organs.

[15]  A. Besarab,et al.  Detection of Access Strictures and Outlet Stenoses in Vascular Accesses Which Test Is Best? , 1997, ASAIO journal.

[16]  Yukihiko Nosé,et al.  Can We Develop a Nonpulsatile Permanent Rotary Blood Pump? Yes, We Can. , 1996, Artificial organs.

[17]  G Damm,et al.  Initial clinical experience with the Baylor-Nikkiso centrifugal pump. , 1995, Artificial organs.

[18]  J M Fuqua,et al.  Five month survival in a calf supported with an intraventricular axial flow blood pump. , 1995, ASAIO journal.

[19]  G P Noon,et al.  Clinical experience with BioMedicus centrifugal ventricular support in 172 patients. , 1995, Artificial organs.

[20]  T. Demmy,et al.  Improving clinical outcome with centrifugal mechanical assist for postcardiotomy ventricular failure. , 1995, Artificial organs.