SPECMAR: fast heart rate estimation from PPG signal using a modified spectral subtraction scheme with composite motion artifacts reference generation

AbstractThe task of heart rate estimation using photoplethysmographic (PPG) signal is challenging due to the presence of various motion artifacts in the recorded signals. In this paper, a fast algorithm for heart rate estimation based on modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) is proposed using two-channel PPG and three-axis accelerometer signals. First, the preliminary noise reduction is obtained by filtering unwanted frequency components from the recorded signals. Next, a composite motion artifacts reference generation method is developed to be employed in the proposed SPECMAR algorithm for motion artifacts reduction. The heart rate is then computed from the noise and motion artifacts reduced PPG signal. Finally, a heart rate tracking algorithm is proposed considering neighboring estimates. The performance of the SPECMAR algorithm has been tested on publicly available PPG database. The average heart rate estimation error is found to be 2.09 BPM on 23 recordings. The Pearson correlation is 0.9907. Due to low computational complexity, the method is faster than the comparing methods. The low estimation error, smooth and fast heart rate tracking makes SPECMAR an ideal choice to be implemented in wearable devices. Graphical AbstractFlow chart for the heart rate estimation using modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) from photoplethysmographic (PPG) signals.

[1]  Prasanta Kumar Ghosh,et al.  Multiple Spectral Peak Tracking for Heart Rate Monitoring from Photoplethysmography Signal During Intensive Physical Exercise , 2015, IEEE Signal Processing Letters.

[2]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[3]  Shaikh Anowarul Fattah,et al.  A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal , 2017, Biomed. Signal Process. Control..

[4]  Shaikh Anowarul Fattah,et al.  Cascade and parallel combination (CPC) of adaptive filters for estimating heart rate during intensive physical exercise from photoplethysmographic signal , 2017, Healthcare technology letters.

[5]  S. Seyedtabaii,et al.  Kalman Filter Based Adaptive Reduction of Motion Artifact from Photoplethysmographic Signal , 2008 .

[6]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[7]  Mehrdad Nourani,et al.  A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors , 2014, IEEE Journal of Biomedical and Health Informatics.

[8]  D. Altman,et al.  Comparing methods of measurement: why plotting difference against standard method is misleading , 1995, The Lancet.

[9]  Zhilin Zhang,et al.  Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction , 2015, IEEE Transactions on Biomedical Engineering.

[10]  H. Asada,et al.  Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Andriy Temko,et al.  Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase vocoder , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[12]  Andrew L. Rukhin,et al.  Analysis of Time Series Structure SSA and Related Techniques , 2002, Technometrics.

[13]  Anil Kumar Tiwari,et al.  Heart monitoring systems - A review , 2014, Comput. Biol. Medicine.

[14]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[15]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[16]  Manojit Pramanik,et al.  Review on Heart-Rate Estimation from Photoplethysmography and Accelerometer Signals During Physical Exercise , 2017, Journal of the Indian Institute of Science.

[17]  P A Kyriacou,et al.  Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients. , 2002, Physiological measurement.

[18]  Giuseppe Baselli,et al.  A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters , 2016, Medical & Biological Engineering & Computing.

[19]  T. Fu,et al.  Heart Rate Extraction from Photoplethysmogram Waveform Using Wavelet Multi-resolution Analysis , 2008 .