Metacarpophalangeal joint arthroplasty in rheumatoid arthritis. A long-term assessment.

BACKGROUND The long-term results of silicone metacarpophalangeal arthroplasty in patients with rheumatoid arthritis are uncertain. The purpose of this investigation was to evaluate the subjective, objective, and radiographic outcomes at the time of long-term follow-up. METHODS Patients with rheumatoid arthritis who underwent simultaneous silicone metacarpophalangeal joint arthroplasties of all four fingers by one surgeon were eligible for inclusion in the study. The results of a total of 208 arthroplasties in fifty-two hands of thirty-six patients were evaluated at an average of fourteen years postoperatively. Active metacarpophalangeal joint motion, ulnar drift, and radiographs were assessed. The radiographs were reviewed for changes in bone length, erosions, and implant fractures. The Michigan Hand Outcomes Questionnaire (MHQ) was administered to the patients. RESULTS The mean arc of motion of the metacarpophalangeal joints improved from 30 degrees preoperatively to 46 degrees immediately after the surgery but decreased to 36 degrees at the time of final follow-up. The mean extension deficit of the metacarpophalangeal joints improved from 57 degrees preoperatively to 11 degrees immediately after the surgery but worsened to 23 degrees at the time of final follow-up. The mean ulnar drift improved from 26 degrees preoperatively to <5 degrees in the immediate postoperative period and then recurred to an average of 16 degrees at the time of final follow-up. Implant fractures were associated with increased ulnar drift (p < 0.001). Bone reaction adjacent to the implant was demonstrated by bone-shortening in most patients and by erosions in 29% of the patients. One hundred and thirty implants (63%) were broken and forty-five (22%) more were deformed at the time of final follow-up. The MHQ score averaged 48 of 100 points. The patients expressed satisfaction with the function of only 38% of the hands, and only 27% of the hands were pain-free at the time of final follow-up. A greater degree of ulnar drift was associated with decreased patient satisfaction and a decreased score for the cosmetic appearance (p </= 0.01). CONCLUSIONS The outcome after silicone metacarpophalangeal joint arthroplasty in patients with rheumatoid arthritis worsens with long-term follow-up. Given these findings, the indications for and long-term expectations of silicone metacarpophalangeal arthroplasty must be carefully examined in light of the improvements in the medical management of rheumatoid disease.

[1]  A. Swanson,et al.  Flexible implant arthroplasty for arthritic finger joints: rationale, technique, and results of treatment. , 1972, The Journal of bone and joint surgery. American volume.

[2]  L. Mannerfelt,et al.  Silastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis , 1975 .

[3]  A. Movin,et al.  Metacarpophalangeal joint implants. I. Roentgenographic study on the silastic finger joint implant, swanson design. , 1975, Scandinavian journal of plastic and reconstructive surgery.

[4]  R. Linscheid,et al.  Review and analysis of silicone-rubber metacarpophalangeal implants. , 1976, The Journal of bone and joint surgery. American volume.

[5]  J. Buckwalter,et al.  Metacarpophalangeal joint implant arthroplasty with a Silastic spacer. , 1984, The Journal of bone and joint surgery. American volume.

[6]  E. Bieber,et al.  Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis. , 1986, The Journal of bone and joint surgery. American volume.

[7]  B. Levack,et al.  Metacarpo-phalangeal joint replacement with a new prosthesis: description and preliminary results of treatment with the Helal flap joint. , 1987, Journal of hand surgery.

[8]  J. W. Strickland,et al.  Long-term evaluation of Silastic trapezial arthroplasty in patients with osteoarthritis. , 1991, The Journal of hand surgery.

[9]  Y. Wilson,et al.  Long-Term Follow-Up of Swanson’s Silastic Arthroplasty of the Metacarpophalangeal Joints in Rheumatoid Arthritis , 1993, Journal of hand surgery.

[10]  D. Kirschenbaum,et al.  Arthroplasty of the metacarpophalangeal joints with use of silicone-rubber implants in patients who have rheumatoid arthritis. Long-term results. , 1993, The Journal of bone and joint surgery. American volume.

[11]  P Gebuhr,et al.  Silastic arthroplasty in rheumatoid MCP-joints. 60 joints followed for 7 years. , 1994, Acta orthopaedica Scandinavica.

[12]  P J Stern,et al.  High implant fracture incidence with Sutter silicone metacarpophalangeal joint arthroplasty. , 1996, The Journal of hand surgery.

[13]  J. Edwards,et al.  Patterns of Cellular Activation after Tendon Injury , 1996, Journal of hand surgery.

[14]  K K Hansraj,et al.  Swanson metacarpophalangeal joint arthroplasty in patients with rheumatoid arthritis. , 1997, Clinical orthopaedics and related research.

[15]  R. Hayward,et al.  Reliability and validity testing of the Michigan Hand Outcomes Questionnaire. , 1998, The Journal of hand surgery.

[16]  R. Hayward,et al.  The Michigan Hand Outcomes Questionnaire (MHQ): assessment of responsiveness to clinical change. , 1999, Annals of plastic surgery.

[17]  K Schmidt,et al.  Ten-year follow-up of silicone arthroplasty of the metacarpophalangeal joints in rheumatoid hands. , 1999, Scandinavian journal of plastic and reconstructive surgery and hand surgery.

[18]  P. Emery,et al.  The therapeutic approach of early intervention for rheumatoid arthritis: what is the evidence? , 2001, Rheumatology.

[19]  D. Pisetsky,et al.  Progress in the treatment of rheumatoid arthritis. , 2001, JAMA.