Impact of shadow on the performances of a domestic photovoltaic pumping system incorporating an MPPT control: A case study in Bejaia, North Algeria

Photovoltaic (PV) solar energy is the solution combining economy and efficiency for the supply of stand alone systems. This combination can only be achieved by taking into account the effects of shading which have dramatic consequences on the electrical power delivered. In this paper, we present an experimental study of the effect of shading PV array on a pumping system performance. The experimental bench is installed at the Industrial Technology and Information Laboratory (LTII) in Bejaia (Algeria). In order to test the performances of the proposed system we propose different array configurations which show different behaviors against partial shading conditions. Shadow impacts fundamentally the global PV pumping system production; its influence is difficult to model because it depends on many parameters such as the configuration of the PV array, the relative rate of shadow, and the shaded area of the module. In general, it is better to have a completely shaded string than several partially shaded ones. These are ones of the most important conclusions obtained in this work.

[1]  Djamila Rekioua,et al.  Improved direct torque control of an induction generator used in a wind conversion system connected to the grid. , 2013, ISA transactions.

[2]  D. Langridge,et al.  Development of a photo-voltaic pumping system using a brushless D.C. motor and helical rotor pump , 1996 .

[3]  M. Benghanem,et al.  Effect of pumping head on solar water pumping system , 2014 .

[4]  Faicel Hnaien,et al.  Estimation of Global Solar Radiation Using Three Simple Methods , 2013 .

[5]  Miguel Ángel Egido,et al.  Automatic fault diagnosis in PV systems with distributed MPPT , 2013 .

[6]  A. Bidram,et al.  Control and Circuit Techniques to Mitigate Partial Shading Effects in Photovoltaic Arrays , 2012, IEEE Journal of Photovoltaics.

[7]  Engin Karatepe,et al.  Performance enhancement of photovoltaic array through string and central based MPPT system under non-uniform irradiance conditions , 2012 .

[8]  Mutlu Boztepe,et al.  Voltage based power compensation system for photovoltaic generation system under partially shaded insolation conditions , 2008 .

[9]  Abdelhamid Midoun,et al.  Performance of a directly-coupled PV water pumping system , 2011 .

[10]  Makbul Anwari,et al.  Modeling and Simulation of Photovoltaic Water Pumping System , 2009, 2009 Third Asia International Conference on Modelling & Simulation.

[11]  Belkacem Bouzidi,et al.  New sizing method of PV water pumping systems , 2013 .

[12]  Djamila Rekioua,et al.  Modeling and Simulation of a Photovoltaic System Using Fuzzy Logic Controller , 2009, 2009 Second International Conference on Developments in eSystems Engineering.

[13]  Jeong Tai Kim,et al.  Optimization of the building integrated photovoltaic system in office buildings—Focus on the orientation, inclined angle and installed area , 2012 .

[14]  Moncef Jraidi,et al.  Theoretical and experimental analysis of the behaviour of a photovoltaic pumping system , 2009 .

[15]  Vivek Agarwal,et al.  Maximum Power Point Tracking Scheme for PV Systems Operating Under Partially Shaded Conditions , 2008, IEEE Transactions on Industrial Electronics.

[16]  A. B. Sebitosi,et al.  A new topology to mitigate the effect of shading for small photovoltaic installations in rural sub-Saharan Africa , 2009 .

[17]  Mahmoud Hammad,et al.  A unified approach for designing a photovoltaic solar system for the underground water pumping well-34 at Disi aquifer , 2013 .

[18]  Y.Roger Hsiao,et al.  Direct coupling of photovoltaic power source to water pumping system , 1984 .

[19]  A. Hamidat,et al.  Modelling photovoltaic water pumping systems and evaluation of their CO2 emissions mitigation potential , 2010 .

[20]  İlyas Eker,et al.  Nonlinear modeling and identification of a DC motor for bidirectional operation with real time experiments , 2004 .

[21]  Javier Cuadrado,et al.  Geared PM coreless motor modelling for driver’s force feedback in steer-by-wire systems , 2011 .

[22]  Brian Norton,et al.  Influence of pumping head, insolation and PV array size on PV water pumping system performance , 2006 .

[23]  M. M. A. Salama,et al.  Optimal Photovoltaic Array Reconfiguration to Reduce Partial Shading Losses , 2013, IEEE Transactions on Sustainable Energy.

[24]  Ion E. Opris,et al.  Model-based method for partially shaded PV modules Hot Spot Suppression , 2013, 2012 IEEE 38th Photovoltaic Specialists Conference (PVSC) PART 2.

[25]  Yi-Hwa Liu,et al.  A Particle Swarm Optimization-Based Maximum Power Point Tracking Algorithm for PV Systems Operating Under Partially Shaded Conditions , 2012, IEEE Transactions on Energy Conversion.

[26]  A. Hadj Arab,et al.  Performances study of different PV powered DC pump configurations for an optimum energy rating at different heads under the outdoor conditions of a desert area , 2012 .

[27]  Adel A. Ghoneim,et al.  Design optimization of photovoltaic powered water pumping systems , 2006 .

[28]  Djamila Rekioua,et al.  Optimization of Photovoltaic Power Systems: Modelization, Simulation and Control , 2012 .

[29]  Ben Ghanem Belgacem Performance of submersible PV water pumping systems in Tunisia , 2012 .

[30]  M. Mohanraj,et al.  Renewable energy source water pumping systems—A literature review , 2013 .

[31]  Pr Djamila Rekioua Optimization of Photovoltaic Power Systems , 2012 .

[32]  Djamila Rekioua,et al.  DSP-controlled direct torque control of induction machines based on modulated hysteresis control , 2009, 2009 International Conference on Microelectronics - ICM.