Three-dimensional hemodynamic design optimization of stents for cerebral aneurysms

Flow-diverting stents occlude aneurysms by diverting the blood flow from entering the aneurysm sac. Their effectiveness is determined by the thrombus formation rate, which depends greatly on stent design. The aim of this study was to provide a general framework for efficient stent design using design optimization methods, with a focus on stent hemodynamics as the starting point. Kriging method was used for completing design optimization. Three different cases of idealized stents were considered, and 40–60 samples from each case were evaluated using computational fluid dynamics. Using maximum velocity and vorticity reduction as objective functions, the optimized designs were identified from the samples. A number of optimized stent designs have been found from optimization, which revealed that a combination of high pore density and thin struts is desired. Additionally, distributing struts near the proximal end of aneurysm neck was found to be effective. The success of the methods and framework devised in this study offers a future possibility of incorporating other disciplines to carry out multidisciplinary design optimization.

[1]  A. Wakhloo,et al.  Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity , 1997, Annals of Biomedical Engineering.

[2]  A. A. Hassan,et al.  The adverse effects of flow-diverter stent-like devices on the flow pattern of saccular intracranial aneurysm models: computational fluid dynamics study , 2011, Acta Neurochirurgica.

[3]  Abdul I. Barakat,et al.  Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents , 2005, Annals of Biomedical Engineering.

[4]  Z Kulcsar,et al.  Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device , 2010, American Journal of Neuroradiology.

[5]  Charles A. Taylor,et al.  Comparison of CFD and MRI Flow and Velocities in an In Vitro Large Artery Bypass Graft Model , 2005, Annals of Biomedical Engineering.

[6]  R. Higashida,et al.  Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literature. , 1997, Journal of neurosurgery.

[7]  J. Lasheras The Biomechanics of Arterial Aneurysms , 2007 .

[8]  T. Liou,et al.  Intra-aneurysmal flow with helix and mesh stent placement across side-wall aneurysm pore of a straight parent vessel. , 2004, Journal of biomechanical engineering.

[9]  E. Levy,et al.  The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation. , 2004, Neurosurgery.

[10]  N. Stergiopulos,et al.  Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral Aneurysms , 2011, Annals of Biomedical Engineering.

[11]  Toshio Nakayama,et al.  Development of Stent Strut Pattern for Cerebral Aneurysm , 2010 .

[12]  Robert F Spetzler,et al.  Percutaneous intracranial stent placement for aneurysms. , 2003, Journal of neurosurgery.

[13]  C. Putman,et al.  Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment , 2010, American Journal of Neuroradiology.

[14]  S. C. Yu,et al.  A steady flow analysis on the stented and non-stented sidewall aneurysm models. , 1999, Medical engineering & physics.

[15]  Douglas C. Montgomery,et al.  Response Surface Methodology: Process and Product Optimization Using Designed Experiments , 1995 .

[16]  Bastien Chopard,et al.  Numerical analysis of the flow pattern in stented aneurysms and its relation to velocity reduction and stent efficiency , 2006, Math. Comput. Simul..

[17]  Miki Hirabayashi,et al.  Characterization of flow reduction properties in an aneurysm due to a stent. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[18]  Shigeru Obayashi,et al.  Two-Dimensional Optimization of a Stent for an Aneurysm , 2010 .

[19]  Hui Meng,et al.  Comparison of Two Stents in Modifying Cerebral Aneurysm Hemodynamics , 2008, Annals of Biomedical Engineering.

[20]  H. Harasaki,et al.  Effects of stent design and serum cholesterol level on the restenosis rate in atherosclerotic rabbits. , 1993, American heart journal.

[21]  M. Kibbe,et al.  Nitric Oxide: What a Vascular Surgeon Needs to Know , 2007, Vascular.

[22]  A. Wakhloo,et al.  Stents for intracranial aneurysms: the beginning of a new endovascular era? , 1998, Neurosurgery.

[23]  D. Fiorella,et al.  CURATIVE RECONSTRUCTION OF A GIANT MIDBASILAR TRUNK ANEURYSM WITH THE PIPELINE EMBOLIZATION DEVICE , 2009, Neurosurgery.

[24]  C. Gandhi,et al.  The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial , 2012 .

[25]  Shigeru Obayashi,et al.  Multi-Objective Design Exploration for Aerodynamic Configurations , 2005 .

[26]  A. Wakhloo,et al.  Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms. , 1999, Journal of neurosurgery.

[27]  David F Kallmes,et al.  Flow Diversion for Intracranial Aneurysms: A Review , 2011, Stroke.

[28]  Shigeru Obayashi,et al.  Kriging-Based Probabilistic Method for Constrained Multi- Objective Optimization Problem , 2004 .

[29]  Baruch B. Lieber,et al.  Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow , 2002, Annals of Biomedical Engineering.

[30]  Kyehan Rhee,et al.  Changes of Flow Characteristics by Stenting in Aneurysm Models: Influence of Aneurysm Geometry and Stent Porosity , 2002, Annals of Biomedical Engineering.

[31]  S Chien,et al.  Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. , 1966, Journal of applied physiology.

[32]  Carlos Miranda,et al.  CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE , 2009, Neurosurgery.

[33]  D. Fiorella,et al.  Usefulness of the Neuroform Stent for the Treatment of Cerebral Aneurysms: Results at Initial (3–6-mo) Follow-up , 2005, Neurosurgery.

[34]  Simon Wildermuth,et al.  Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation , 2005, CardioVascular and Interventional Radiology.

[35]  Nicholas A J Lieven,et al.  35th AIAA Fluid Dynamics Conference and Exhibit , 2005 .

[36]  J. Xiang,et al.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents. , 2010, World neurosurgery.

[37]  H. Meng,et al.  Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study. , 2004, Journal of neurosurgery.

[38]  Kazuomi Yamamoto,et al.  Efficient Optimization Design Method Using Kriging Model , 2005 .

[39]  Charles A. Taylor,et al.  Intracranial and abdominal aortic aneurysms: similarities, differences, and need for a new class of computational models. , 2008, Annual review of biomedical engineering.

[40]  R. Vanninen,et al.  Broad-based intracranial aneurysms: thrombosis induced by stent placement. , 2003, AJNR. American journal of neuroradiology.

[41]  J. Palmaz,et al.  Intravascular stents: tissue-stent interactions and design considerations. , 1993, AJR. American journal of roentgenology.

[42]  H. Florian,et al.  Numerical blood flow analysis: Arterial bifurcation with a saccular aneurysm , 2005, Basic Research in Cardiology.

[43]  R. Jenkins,et al.  Thrombosis of difficult intracranial aneurysms by the endovascular placement of platinum-Dacron microcoils. , 1992, Journal of neurosurgery.

[44]  Bastien Chopard,et al.  Optimization of flow diverters for cerebral aneurysms , 2012, J. Comput. Sci..