Two-dimensional temperature estimation using diagnostic ultrasound

A two-dimensional temperature estimation method was developed based on the detection of shifts in echo location of backscattered ultrasound from a region of tissue undergoing thermal therapy. The echo shifts are due to the combination of the local temperature dependence of speed of sound and thermal expansion in the heated region. A linear relationship between these shifts and the underlying tissue temperature rise is derived from first principles and experimentally validated. The echo shifts are estimated from the correlation of successive backscattered ultrasound frames, and the axial derivative of the accumulated echo shifts is shown to be proportional to the temperature rise. Sharp lateral gradients in the temperature distribution introduce ripple on the estimates of the echo shifts due to a thermo-acoustic lens effect. This ripple can be effectively reduced by filtering the echo shifts along the axial and lateral directions upon differentiation. However, this is achieved at the expense of spatial resolution. Experimental evaluation of the accuracy (0.5/spl deg/C) and spatial resolution (2 mm) of the algorithm in tissue mimicking phantoms was conducted using a diagnostic ultrasound imaging scanner and a therapeutic ultrasound unit. The estimated temperature maps were overlaid on the gray-scale ultrasound images to illustrate the applicability of this technique for image guidance of focused ultrasound thermal therapy.

[1]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  C. Damianou,et al.  Tissue temperature estimation in-vivo with pulse-echo , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[3]  J.-L. Thomas,et al.  Ultrasonic beam focusing through tissue inhomogeneities with a time reversal mirror: application to transskull therapy , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  C. Damianou,et al.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model. , 1996, The Journal of the Acoustical Society of America.

[5]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[6]  K. W. Marich,et al.  Early experience with high-intensity focused ultrasound for the treatment of benign prostatic hypertrophy. , 1997, British journal of urology.

[7]  R. Seip,et al.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound , 1995, IEEE Transactions on Biomedical Engineering.

[8]  K D Paulsen,et al.  Initial in vivo experience with EIT as a thermal estimator during hyperthermia. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[9]  Ultrasonic speed as a parameter for non-invasive thermometry , 1987 .

[10]  Ralf Seip Feedback for ultrasound thermotherapy. , 1996 .

[11]  P. VanBaren,et al.  Non-invasive spatio-temporal temperature estimation using diagnostic ultrasound , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[12]  P. VanBaren,et al.  Image-guided phased array system for ultrasound thermotherapy , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[13]  R. M. Arthur,et al.  Theoretical estimation of the temperature dependence of backscattered ultrasonic power for noninvasive thermometry. , 1994, Ultrasound in medicine & biology.

[14]  David L. Donoho,et al.  De-noising by soft-thresholding , 1995, IEEE Trans. Inf. Theory.

[15]  P. VanBaren,et al.  Noninvasive real-time multipoint temperature control for ultrasound phased array treatments , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  P. VanBaren,et al.  Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[17]  C. Damianou,et al.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study. , 1996, The Journal of the Acoustical Society of America.

[18]  J M Dubernard,et al.  Treatment of prostate cancer with transrectal focused ultrasound: early clinical experience. , 1996, European urology.

[19]  H. Fukukita,et al.  Ultrasound thermometry in hyperthermia , 1990, IEEE Symposium on Ultrasonics.

[20]  W.D. O'Brien,et al.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  P. VanBaren,et al.  Motion compensation algorithm for noninvasive two-dimensional temperature estimation using diagnostic pulse-echo ultrasound , 1998, Photonics West - Biomedical Optics.

[22]  J.T. Powers,et al.  An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  K. Hynynen,et al.  Feasibility of using ultrasound phased arrays for MRI monitored noninvasive surgery , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  J R Mallard,et al.  Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. , 1983, The British journal of radiology.

[25]  Alan V. Oppenheim,et al.  Discrete-Time Signal Pro-cessing , 1989 .

[26]  P.M. Meaney,et al.  Microwave imaging for tissue assessment: initial evaluation in multitarget tissue-equivalent phantoms , 1996, IEEE Transactions on Biomedical Engineering.