Precision Evaluation of Three-dimensional Feature Points Measurement by Binocular Vision

Binocular-pair images obtained from two cameras can be used to calculate the three-dimensional (3D) world coordinate of a feature point. However, to apply this method, measurement accuracy of binocular vision depends on some structure factors. This paper presents an experimental study of measurement distance, baseline distance, and baseline direction. Their effects on camera reconstruction accuracy are investigated. The testing set for the binocular model consists of a series of feature points in stereo-pair images and corresponding 3D world coordinates. This paper discusses a method to increase the baseline distance of two cameras for enhancing the accuracy of a binocular vision system. Moreover, there is an inflexion point of the value and distribution of measurement errors when the baseline distance is increased. The accuracy benefit from increasing the baseline distance is not obvious, since the baseline distance exceeds 1000 mm in this experiment. Furthermore, it is observed that the direction errors deduced from the set-up are lower when the main measurement direction is similar to the baseline direction.

[1]  Zeev Zalevsky,et al.  Optical technique for classification, recognition and identification of obscured objects , 2010 .

[2]  Zhengyou Zhang,et al.  Flexible camera calibration by viewing a plane from unknown orientations , 1999, Proceedings of the Seventh IEEE International Conference on Computer Vision.

[3]  Yu Yao,et al.  Research on Structural Parameter Optimization of Binocular Vision Measuring System for Parallel Mechanism , 2006, 2006 International Conference on Mechatronics and Automation.

[4]  Ki-Chul Kwon,et al.  Automatic Control of Horizontal-moving Stereoscopic Camera by Disparity Compensation , 2001 .

[5]  Byoungho Lee,et al.  An Improved Stereovision Scheme Using Single Camera and a Composite Lens Array , 2004 .

[6]  Tomás Svoboda,et al.  A Convenient Multicamera Self-Calibration for Virtual Environments , 2005, Presence: Teleoperators & Virtual Environments.

[7]  Wei Sun,et al.  An empirical evaluation of factors influencing camera calibration accuracy using three publicly available techniques , 2006, Machine Vision and Applications.

[8]  Yu Fu,et al.  Digital image correlation for whole field out-of-plane displacement measurement using a single camera , 2005 .

[9]  Tianran Yuan,et al.  A three-step system calibration procedure with error compensation for 3D shape measurement , 2010 .

[10]  Hirokazu Kato,et al.  Marker tracking and HMD calibration for a video-based augmented reality conferencing system , 1999, Proceedings 2nd IEEE and ACM International Workshop on Augmented Reality (IWAR'99).

[11]  Chul Geun Park,et al.  A High-speed Digital Laser Grating Projection System for the Measurement of 3-dimensional Shapes , 2009 .

[12]  Zhongwei Li,et al.  Complex object 3D measurement based on phase-shifting and a neural network , 2009 .

[13]  Sundaram Ganapathy,et al.  Decomposition of transformation matrices for robot vision , 1984, Pattern Recognit. Lett..

[14]  Carlos Ricolfe-Viala,et al.  Robust metric calibration of non-linear camera lens distortion , 2010, Pattern Recognit..

[15]  R. Y. Tsai,et al.  An Efficient and Accurate Camera Calibration Technique for 3D Machine Vision , 1986, CVPR 1986.

[16]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[17]  Bin Xu,et al.  Modeling of binocular vision system for 3D reconstruction with improved genetic algorithms , 2006 .

[18]  Gyeong-il Kweon,et al.  Image-processing Based Panoramic Camera Employing Single Fisheye Lens , 2010 .

[19]  Brian James O'Kennedy,et al.  Stereo camera calibration , 2002 .

[20]  Roger Y. Tsai,et al.  Techniques for Calibration of the Scale Factor and Image Center for High Accuracy 3-D Machine Vision Metrology , 1988, IEEE Trans. Pattern Anal. Mach. Intell..

[21]  Pearl Pu,et al.  A new development in camera calibration calibrating a pair of mobile cameras , 1985, Proceedings. 1985 IEEE International Conference on Robotics and Automation.

[22]  Roger Y. Tsai,et al.  Techniques for calibration of the scale factor and image center for high accuracy 3D machine vision metrology , 1987, Proceedings. 1987 IEEE International Conference on Robotics and Automation.

[23]  Young-Tae Lim,et al.  Vergence Control of Binocular Stereoscopic Camera Using Disparity Information , 2009 .

[24]  H. Hatze,et al.  High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approach. , 1988, Journal of biomechanics.

[25]  Eun-Soo Kim,et al.  Computational Integral Imaging Reconstruction of 3D Object Using a Depth Conversion Technique , 2008 .