A model based upon pseudo regular spacing of cells combined with the randomisation of the nuclei can explain the significant changes in high-frequency ultrasound signals during apoptosis.

Recent ultrasound (US) experiments on packed myeloid leukaemia cells have shown that, at frequencies from 32 to 40 MHz, significant increases of signal amplitude were observed during apoptosis. This paper is an attempt to explain these signal increases based upon a simulation of the backscattered signals from the cells nuclei. The simulation is an expansion of work in which a condensed sample of cells, with fairly regular sizes, could be considered as an imperfect crystal. Thus, destructive interference could occur and this would be observed as a large reduced value of backscattered signals compared with the values obtained from a similar, but random, scattering source. This current paper explores the possibility that simple changes in the nuclei, such as their observed condensation or the small loss of nuclei scatterers from cells, could cause a significant increase in the observed backscattered signals. This model indicates that the greater backscattered signals can be explained by further randomisation of the average positions of the scattering sources in each cell. When these "microechoes" are added together, so that the destructive interference is reduced, a large increase in the signal is predicted. The simplified model strongly suggests that much of observed large increases of the backscattered signals could be simply explained by the randomisation of the position of the condensed nuclei during apoptosis, and the destruction of the nuclei could produce further signal amplitude changes due to disruption of the cloud of backscattered waves.

[1]  F. S. Foster,et al.  Ultrasound backscatter microscopy images the internal structure of living tumour spheroids , 1987, Nature.

[2]  T. Hall,et al.  Characterising the microstructure of random media using ultrasound. , 1990, Physics in medicine and biology.

[3]  F. Foster,et al.  Quantitative contrast measurements in B-mode images comparison between experiment and theory. , 1986, Ultrasound in medicine & biology.

[4]  K. Nagayama,et al.  Local mechanical properties measured by atomic force microscopy for cultured bovine endothelial cells exposed to shear stress. , 2000, Journal of biomechanics.

[5]  Ronald H. Silverman,et al.  Ultrasonic spectrum analysis for assays of different scatterer morphologies: theory and very-high frequency clinical results , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[6]  P. Shankar,et al.  Ultrasound speckle analysis based on the K distribution. , 1991, The Journal of the Acoustical Society of America.

[7]  B. Goldberg,et al.  Comparisons of the Rayleigh and K-distribution models using in vivo breast and liver tissue. , 1998, Ultrasound in medicine & biology.

[8]  M S Patterson,et al.  Computer Simulations of Speckle in B-Scan Images , 1983, Ultrasonic imaging.

[9]  J. Tarbell,et al.  Effect of flow disturbance on ultrasonic backscatter from blood. , 1984, The Journal of the Acoustical Society of America.

[10]  T J Hall,et al.  Identifying acoustic scattering sources in normal renal parenchyma in vivo by varying arterial and ureteral pressures. , 1992, Ultrasound in medicine & biology.

[11]  Michael C. Kolios,et al.  Ultrasonic biomicroscopy of viable, dead and apoptotic cells. , 1997, Ultrasound in medicine & biology.

[12]  R. Cobbold,et al.  A unified approach to modeling the backscattered Doppler ultrasound from blood , 1992, IEEE Transactions on Biomedical Engineering.

[13]  R S Cobbold,et al.  On the relation between aggregation, packing and the backscattered ultrasound signal for whole blood. , 1999, Ultrasound in medicine & biology.

[14]  J W Hunt,et al.  © 1999 Cancer Research Campaign Article no. bjoc.1999.0724 Ultrasound imaging of apoptosis: high-resolution noninvasive , 2022 .

[15]  G. Truskey,et al.  Atomic force and total internal reflection fluorescence microscopy for the study of force transmission in endothelial cells. , 2000, Biophysical journal.

[16]  J W Hunt,et al.  The subtleties of ultrasound images of an ensemble of cells: simulation from regular and more random distributions of scatterers. , 1995, Ultrasound in medicine & biology.

[17]  J. G. Miller,et al.  Anisotropy of the ultrasonic attenuation in soft tissues: measurements in vitro. , 1990, The Journal of the Acoustical Society of America.

[18]  R. Hotchkiss,et al.  Stress-induced fractal rearrangement of the endothelial cell cytoskeleton causes apoptosis. , 1998, Surgery.

[19]  J C Bamber,et al.  Ultrasonic B-scanning: a computer simulation , 1980, Physics in medicine and biology.

[20]  E. Feleppa,et al.  Relationship of Ultrasonic Spectral Parameters to Features of Tissue Microstructure , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  D J Coleman,et al.  Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology. , 1995, Ophthalmology.

[22]  J W Hunt,et al.  A method for computer simulation of ultrasound Doppler color flow images--I. Theory and numerical method. , 1992, Ultrasound in medicine & biology.

[23]  P M Shankar,et al.  Studies on the use of non-Rayleigh statistics for ultrasonic tissue characterization. , 1996, Ultrasound in medicine & biology.

[24]  P. Shankar A general statistical model for ultrasonic backscattering from tissues , 2000 .

[25]  M Tanaka,et al.  Visualization of human umbilical vein endothelial cells by acoustic microscopy. , 2000, Ultrasonics.

[26]  Michael C. Kolios,et al.  Ultrasound Imaging of Apoptosis , 2002 .

[27]  F. Foster,et al.  Use of a high frequency ultrasound microscope to image the action of 2-nitroimidazoles in multicellular spheroids. , 1992, British Journal of Cancer.